MEANWELL P25A-T_07

P25A-T
25W AC-DC Triple Output Desktop
series
Features :
3 pole AC inlet IEC320-C14
Class
power (with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temp.
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: Top switch circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
1 year warranty
TUV
Rheinland
Product Safety
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
P25A13D-R1B
P25A14E-R1B
PSU25A-13D
PSU25A-14E
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
2.5A
0.8A
0.3A
2.5A
0.8A
0.3A
2.5A
0.5A
0.3A
CURRENT RANGE
0.5 ~ 2.5A
0.1 ~ 0.8A
0.1 ~ 0.3A
0.5 ~ 2.5A
0.1~0.8A
0.1 ~0.3A
0.5 ~ 2.5A
0.1 ~ 0.5A
0.1 ~ 0.3A
RATED POWER
25W
100mVp-p
100mVp-p
DC VOLTAGE
OUTPUT
P25A13A-R1B
PSU25A-13A
Note.2 5V
geprUfre
Sicherheit
25W
RIPPLE & NOISE (max.) Note.3 50mVp-p
100mVp-p
100mVp-p
50mVp-p
25W
100mVp-p
100mVp-p
50mVp-p
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
3.0%
5.0%
5.0%
3.0%
5.0%
5.0%
3.0%
LINE REGULATION
Note.5
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
Note.6
4.0%
4.0%
2.0%
4.0%
4.0%
2.0%
4.0%
4.0%
2.0%
SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms at full load
INPUT
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
70%
AC CURRENT
INRUSH CURRENT (max.)
0.8A / 100VAC
60A / 230VAC
0.75mA / 240VAC
OVERLOAD
110 ~ 140% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
0 ~ +40
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note. 7)
HARMONIC CURRENT
NOTE
74%
150 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
CONNECTOR
72%
LEAKAGE CURRENT (max.)
PROTECTION
OTHERS
135 ~ 370VDC
EMS IMMUNITY
MTBF
DIMENSION
-20 ~ +85
0.03% /
(Refer to output load derating curve)
, 10 ~ 95% RH
(0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1950, CSA22.2, EN60950-1 Approved
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) class B
Compliance to EN61000-3-2,3 class A
Compliance to EN61000-4-2,3,4,5,6,11, Light industry level, criteria A
520K hrs min.
MIL-HDBK-217F (25
)
108*67*36mm (L*W*H)
0.3kg ; 54pcs/ 20kg / CARTON
PACKING
PLUG
Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested
CABLE
Standard type UL2464 18AWG*3C 20AWG*2C shield wire *1C with 5fts length for stock ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P25A-T-SPEC 2007-03-01
P25A-T
25W AC-DC Triple Output Desktop
Mechanical Specification
series
Unit:mm
36
UL2464 18AWG 1530+100/-0
MALE CABLE PLUG
106
36
54.8
67
SWITCHING ADAPTOR
10.2
POWER LED
108
Plug Assignment
69.9
18
Standard plug: R1B (option)
33.5
PIN NO OUTPUT
1
3
R1
AC FG
1
o
COM
2
COM
3
+5VDC
4
-Vout
5
+Vout
RUBBER FOOTX4
NAME PLATE
Derating Curve
Static Characteristics
100
LOAD (%)
100
LOAD (%)
45
5 2 4
67
45
42
3
70
0
10
20
Ta (
30
)
40
80
60
0
60
70
80
90 100
260
INPUT VOLTAGE
File Name:P25A-T-SPEC 2007-03-01