PSP-600 600W with PFC and Parallel Function series Features : Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan With DC OK Signal output Current sharing up to 2400W(3+1) Built-in remote ON-OFF control Built-in remote sense function Fixed switching frequency at PFC:88KHz PWM:100KHz 3 years warranty SPECIFICATION MODEL OUTPUT PSP-600-5 PSP-600-12 PSP-600-13.5 PSP-600-15 PSP-600-24 PSP-600-27 DC VOLTAGE 5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 80A 50A 44.5A 40A 25A 22.2A 12.5A CURRENT RANGE 0 ~ 80A 0 ~ 50A 0 ~ 44.5A 0 ~ 40A 0 ~ 25A 0 ~ 22.2A 0 ~ 12.5A RATED POWER 400W 600W 600W 600W 600W 600W 600W RIPPLE & NOISE (max.) Note.2 180mVp-p 240mVp-p 240mVp-p 240mVp-p 240mVp-p 240mVp-p 300mVp-p VOLTAGE ADJ. RANGE 10 ~ 13.2V 1.0% 12 ~ 15V 1.0% 13.5 ~ 18V 1.0% 20 ~ 26.4V 1.0% 24 ~ 30V 1.0% 41 ~ 56V 1.0% 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION LOAD REGULATION PROTECTION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 20ms at full load HOLD UP TIME (Typ.) INPUT 0.5% 1500ms, 50ms at full load SETUP, RISE TIME VOLTAGE RANGE Note.5 88 ~ 264VAC 124 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.95/230VAC EFFICIENCY(Typ.) 79% 84% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 6.8A/115VAC 20A/115VAC 3.4A/230VAC 40A/230VAC 0.99/115VAC at full load 85% 85% EMC (Note 4) <1.3mA/240VAC OVERLOAD OVER VOLTAGE 5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover NOTE 27.6 ~ 32.4V 31 ~ 36.5V 87% 57.6 ~ 67.2V (TSW51) detect on heatsink of power diode OVER TEMPERATURE +12V ~ +48V: 85 (TSW1) detect on heatsink of power transistor; 80 Protection type : Shut down o/p voltage, re-power on to recover REMOTE CONTROL POK SIGNAL WORKING TEMP. RC+/RC-: Short = power on ; Open = power off PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V -20 ~ +60 (Refer to output load derating curve) (TSW51) detect on heatsink of power diode 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF OTHERS 86% 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & 86% LEAKAGE CURRENT +5V: 95 (TSW1) detect on heatsink of power transistor; 95 FUNCTION PSP-600-48 DIMENSION PACKING Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A 116.4K hrs min. MIL-HDBK-217F (25 ) 170*120*93mm (L*W*H) 1.9Kg; 8pcs/15.5Kg/1.06CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:PSP-600-SPEC 2010-10-18 PSP-600 600W with PFC and Parallel Function Mechanical Specification Case No.910A series Unit:mm Terminal JST XHP or equivalent JST SXH-001T or equivalent Pin No. 1 2 3 4 5 6 7 8~11 12~15 Air flow direction Terminal Pin No. Assignment 2-M3 L=4mm max. Assignment AC/L AC/N FG P(Current Share) POK R.C. G R.C. DC OUTPUT +V DC OUTPUT -V 100 Mating Housing 2-M3 L=4mm max. 150 185 170 120 8 1 2 3 150 11.5 4 5 6 7 2-M3 L=4mm max. 2-M3 L=4mm max. 14 max. 93 Assignment RS+ RS- 50 Pin No. 1 2 58.3 RS Connector(CN5) : JST B-XH or equivalent 12 CN5 8 9 10 11 12 13 14 15 9.5 11.5 Block Diagram PFC fosc : 88KHz PWM fosc : 100KHz FAN ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & P.F.C. SIGNAL CONTROL RECTIFIERS & FILTER POWER SWITCHING POK CURRENT SHARING CIRCUIT +V -V RC.G. RC O.C.P. FG O.L.P. P DETECTION CIRCUIT PWM CONTROL O.V.P. O.T.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 Others 90 80 80 70 12V 50 LOAD(%) LOAD (%) 60 40 20 -20 0 10 20 30 40 45 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 88 100 115 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:PSP-600-SPEC 2010-10-18 PSP-600 600W with PFC and Parallel Function series Control Terminal Instruction Manual POK(+) RCG(-) L N FG RCG RC P POK RCG RC L +V +V +V +V -V -V -V -V N FG P POK RCG RC L +V +V +V +V -V -V -V -V RS+ RS- RS+ RS- - + LOAD - + LOAD LOAD Remote Sensing POK Signal P POK RCG RC +V +V +V +V -V -V -V -V RS+ RS- + N FG Remote Control Power ON: RCG and RC for short Power OFF: RCG and RC for open POK Signal is the voltage difference between "RCG" and "POK" pin output POK Signal for TTL level signal PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V Parallel Operation with Remote Sensing (1)Parallel operation is available by connecting the units shown as below (+S,-S and P are connected mutually in parallel) : (2)The voltage difference among each output should be minimized that less than 2% is required. (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit. (6) When in parallel operation, the minimum output load should be greater than 3% of total output load. (Min. load > 3% rated current per unit x number of unit) LOAD +V +S + - P RC- RS+ RS- PSU + - P RC- RS+ RS- PSU -V -S + - P RC- RS+ RS- PSU + - P RC- RS+ RS- PSU File Name:PSP-600-SPEC 2010-10-18