MEANWELL ULP

150W U-Bracket Single Output with PFC Function
ULP-150
series
Features :
Universal AC input / Full range(up to 295VAC)
Built in active PFC compliance to EN61000-3-2 class C
Constant Voltage design
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Half encapsulated
U-bracket low profile:33mm
ZVS technology to reduce power dissipation
Suitable for built-in type LED applications
3 years warranty
SPECIFICATION
MODEL
OUTPUT
ULP-150-12
ULP-150-15
ULP-150-24
ULP-150-36
ULP-150-48
DC VOLTAGE
12V
15V
24V
36V
48V
RATED CURRENT
12.5A
10A
6.3A
4.2A
3.2A
CURRENT RANGE
0 ~ 12.5A
0 ~ 10A
0 ~ 6.3A
0 ~ 4.2A
0 ~ 3.2A
150W
150mVp-p
151.2W
150mVp-p
151.2W
250mVp-p
153.6W
250mVp-p
13.5~16.5V
21.6~26.4V
32.4~39.6V
43.2~52.8V
RATED POWER
150W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
11.0~13.2V
VOLTAGE TOLERANCE Note.3
2.0%
2.0%
2.0%
2.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
1.0%
2000ms, 100ms/230VAC
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms/230VAC
Note.4 90 ~ 295VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
47 ~ 63Hz
PF 0.98/115VAC
3000ms, 100ms/115VAC at full load
16ms/115VAC at full load
127 ~ 417VDC
PF>0.96/230VAC
PF 0.94/277VAC at full load
91.5%
91.5%
2A/115VAC
1A/230VAC
0.7A/277VAC
Cold start 65A/230VAC
93%
93%
93%
<0.75mA / 277VAC
130~185% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
17 ~ 21V
26.7 ~ 32.4V
41.4 ~ 48.6V
13.6 ~ 16.3V
53 ~ 64.8V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
95
5 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 60
TEMP. COEFFICIENT
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
VIBRATION
SAFETY &
EMC
(Note 5)
Design refer to EN61347-2-13,IEC61347-2-13,UL8750
SAFETY STANDARDS
WITHSTAND VOLTAGE Note.6 I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
OTHERS
NOTE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
Compliance to EN55015, EN61000-3-2 Class C( 60% load),EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
216.3K hrs min.
DIMENSION
PACKING
215*67.4*33mm (L*W*H)
0.67kg; 24PCS/17.5kg/0.65CUFT
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
File Name:ULP-150-SPEC 2011-08-11
ULP-150
150W U-Bracket Single Output with PFC Function
Mechanical Specification
Case No. 988
series
Unit:mm
7.5
6.5
4.5 4PL
3.5
194
208
3.5
215
33
3
3
67.4
6.2
2
2
7.62
52
62.7
1
1
7.62
6.2
211
201
4
3.5 4PL
DC Terminal pin NO. Assignment
AC Terminal pin NO. Assignment
Pin No.
1
2
3
Assignment
FG
AC/L
AC/N
Pin No.
1
2
3
4
Terminal
DECA
T31-C032033702
Assignment
VVV+
V+
Terminal
DECA
T31-C032043702
Block Diagram
EMI
FILTER
I/P
BRIDGE
RECTIFIERS
APFC
CONTROLLER
POWER
SWITCHING
SYNCHRONOUS
RECTIFIERS
& FILTER
+V
-V
O.T.P.
FG
O.L.P.
Derating Curve
DETECTION
CIRCUIT
PWM
CONVERTER
O.V.P.
Static Characteristics
100
130
Mount with a 300*500*2mm heatsink
90
100
80
100VAC
60
70
230VAC
LOAD(%)
LOAD (%)
80
40
20
-30
60
50
40
0
10
20
30
40 45 50 55 60 65
AMBIENT TEMPERATURE ( )
70 (HORIZONTAL)
90
100
110
135
155
230
295
INPUT VOLTAGE (V) 60Hz
File Name:ULP-150-SPEC 2011-08-11