HRP-150 150W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit 1U low profile 38mm Built-in remote sense function 5 years warranty SPECIFICATION MODEL OUTPUT HRP-150-3.3 HRP-150-5 HRP-150-7.5 HRP-150-12 HRP-150-15 HRP-150-24 HRP-150-36 HRP-150-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 30A 26A 20A 13A 10A 6.5A 4.3A 3.3A CURRENT RANGE 0 ~ 30A 0 ~ 26A 0 ~ 20A 0 ~ 13A 0 ~ 10A 0 ~ 6.5A 0 ~ 4.3A 0 ~ 3.3A RATED POWER 99W 130W 150W 156W 150W 156W 154.8W 158.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V 2.5% 6.8 ~ 9V 2.5% 10.2 ~ 13.8V 1.5% 13.5 ~ 18V 1.5% 21.6 ~ 28.8V 1.5% 28.8 ~ 39.6V 1.5% 40.8 ~ 55.2V 1.5% 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.5% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 3000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 47 ~ 63Hz FREQUENCY RANGE INPUT PROTECTION 120 ~ 370VDC POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 78.5% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.3A/115VAC 35A/115VAC LEAKAGE CURRENT <1mA / 240VAC OVERLOAD OVER VOLTAGE 3000ms, 50ms/115VAC at full load PF>0.99/115VAC at full load 85% 87% 88% 88% 88% 89% 89% 41.4 ~ 48.6V 57.6 ~ 67.2V 1.3A/230VAC 70A/230VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover 95 (3.3V ~ 7.5V) , 85 (12V ~ 48V) (TSW1 : detect on heatsink Q1 of power transistor) OVER TEMPERATURE 105 WORKING TEMP. Protection type : Shut down o/p voltage , recovers automatically after temperature goes down -40 ~ +70 (Refer to "Derating Curve") (3.3V ~ 7.5V), 100 (12V ~ 48V) (TSW2 : detect on heatsink HS4 of power transistor) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -50 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.04%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION OTHERS NOTE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024 , EN61000-6-2 , heavy industry level, criteria A MTBF 238.8K hrs min. DIMENSION 159*97*38mm (L*W*H) PACKING 0.61Kg; 24pcs/15.6Kg/0.76CUFT MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:HRP-150-SPEC 2011-06-21 HRP-150 150W Single Output with PFC Function I I Mechanical Specification Case No.901I series Unit:mm 3.5 7 152.5 1 3 8.2 5 2-M 6 3L 84.5 4 =4 97 65 9.5 2 7 642 531 3.5 Terminal Pin No. Assignment : 4.5 Pin No. Assignment 4,5 DC OUTPUT -V 6,7 DC OUTPUT +V 159 HRS DF11-**SC or equivalent 6-M3(Both Sides) L=6 22 38 HRS DF11-6DS or equivalent 10 max. 18 Terminal 3.5 Mating Housing 3.5 9 150 9 6.5 Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DSA or equivalent Pin No. Assignment 1 -S 2 +S 3~6 NC 78 24 28.5 Assignment AC/L AC/N FG 18.5 Pin No. 1 2 3 CN100 SVR1 117 Block Diagram fosc :100KHz(3.3~7.5V) 70KHz(12~48V) I/P +S ACTIVE INRUSH CURRENT LIMITING EMI FILTER RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. RECTIFIERS & FILTER +V -V -S DETECTION CIRCUIT FG PFC CONTROL O.T.P. PWM CONTROL Derating Curve O.V.P. Output Derating VS Input Voltage Ta = 25 100 100 Without Cover 90 80 80 70 With Cover LOAD(%) LOAD (%) 60 40 20 -40 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRP-150-SPEC 2011-06-21