MEDER MK02-4-1C90C-500W

Europe: +49 / 7731 8399 0
| Email: [email protected]
Item No.:
USA:
+1 / 508 295 0771
| Email: [email protected]
Asia:
+852 / 2955 1682
| Email: [email protected]
2224903054
Item:
MK02/4-1C90C-500W
Magnetic properties
Pull in
Test equipment
Conditions
Min
Typ
at 20°C
Special Product Data
Contact - form
Contact rating
operating voltage
operating ampere
Switching current
Sensor-resistance
Housing material
Case color
Sealing compound
Max
Unit
Max
Unit
KMS - 11
Conditions
Min
Typ
Form C - Changeover
not to exceed their individual max.'s
DC or Peak AC
DC or Peak AC
DC or Peak AC
! " # $
Sensor deactivated
$
PBT glass fibre reinforced
blue
Polyurethan
Environmental data
Conditions
Min
Operating temperature
Operating temperature
Storage temperature
cable not moved
cable moved
'(
'
'(
Cable specification
Conditions
Min
Cable typ
Cable material
Cross section
Typ
Max
&
&
&
Typ
Unit
%
%
%
Max
Unit
Max
Unit
round cable
PVC
0,14 qmm
Conditions
General data
Mounting advice
Mounting advice
Mounting advice
tightening torque
Min
Typ
over 5m cable, a series resistor is recommended.
The mounting of MK02/4 on iron is not allowed.
Magnetically conductive screws must not be used.
)
* ! +( ,*
Disk ISO 7089
Modifications in the sense of technical progress are reserved
Designed at:
07.03.08
Designed by:
ALICHTENSTEIN
Approval at:
Last Change at:
18.08.09
Last Change by:
KSCHIELENSKI
Approval at:
18.02.11
Approval by:
Approval by:
TFRITSCHI
Version:
03