PANDUIT D-103-36

SPECIFICATION CONTROL DRAWING
Product Revision
Product Name
D-103-33
D-103-34
D-103-35
D-103-36
L
max
M
N
M
M
20.5
(0.805)
‘XY’ = WIRE GAUGE (AWG)
Product Dimensions
øA
øB
K
min
min
min
7.00
(0.275)
7.60
(0.300)
AWG
150
(5.900)
øD
max
22
22
20
20
7.00
(0.275)
Cable Dimensions
øE
J±0.5
min
(J±0.02)
3.56
(0.140)
7.00
(0.275)
Color of
Item 4
black
white
black
white
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked polyvinylidene fluoride.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Sn63 per ANSI-J-STD-006.
FLUX:
TYPE ROL1 per ANSI-J-STD-004.
THERMAL INDICATOR: red.
3. MELTABLE RINGS: Thermally stabilized thermoplastic. Color:gray.
4. GROUND LEAD: Raychem 55A0111-XY in accordance with MIL-W-22759/32 AWG ‘XY’ (see table) stranded
tin plated copper. Color: see table.
APPLICATION
1. These parts are designed to provide an environment protected shield termination on cables, rated for 125°C minimum, meeting the
dimensional criteria listed, having a tin or silverplated copper shields.
2. Temperature range: -55°C to +150°C.
Install using Raychem-approved convection or infrared heating tools in accordance with Raychem process standard RCPS-100-70.
For best results, prepare the cable as shown:
* A trademark of Raychem Corporation.
Raychem
THERMOFIT
DEVICES
Raychem Corporation
300 Constitution Drive
Menlo Park, CA 94025
USA
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
INCHES DIMENSIONS ARE BETWEEN BRACKETS.
Raychem reserves the right to amend this
ANGLES: N/A
TOLERANCES:
drawing at any time. Users should evaluate
0.00 N/A
the suitability of the product for their
ROUGHNESS IN
0.0 N/A
application.
MICRON
0 N/A
TITLE:
SOLDERSLEEVE* DEVICE
WITH PRE-INSTALLED LEAD
DOCUMENT NO.:
D-103-3X
DCR NUMBER:
REPLACES:
D981005
DRAWN BY:
DATE:
PROD. REV.
DOC ISSUE:
M. FORONDA
06/15/98
SEE TABLE
5
If this document is printed it becomes uncontrolled. Check for the latest revision.
SCALE:
None
D1033X
SIZE:
A
SHEET:
1 of 1