FEATURES PETERMANN TECHNIK - HIGH RELIABILITY FOR LOW COST Time & Frequency Components - PECL OUTPUT SIGNAL - COMPLEMENTARY OUTPUT OPTION - FREQUENCY STABILITY TO +-20 PPM - JITTER OPTIMIZED DIP 14 PECL CLOCK OSCILLATOR - EXCELLENT CLOCK SIGNAL GENERATOR FOR TELECOM AND TRANSMISSION SYSTEMS - EXTENDED TEMPERATURE RANGE TO -40/+85°C M6502 SERIES 14 PIN DIP PACKAGE FREQUENCY RANGE 96.0 ~ 160.0 MHz +-20 ~ +-100 ppm FREQUENCY STABILITY +-5 ppm after first year AGING 0/+70°C ~ -40/+85°C OPERATING TEMPERATURE RANGE -55/+125°C STORAGE TEMPERATURE RANGE +5.0 VDC +-5% VOLTAGE INPUT 100 mA max. CURRENT STANDARD 40/60% SYMMETRY OPTION 45/55% RISE AND FALL TIME PECL 1.5 ns max. (20 ~ 80% PECL) OUTPUT "0" LEVEL VDD -1.62V max. PECL 5.0 VOLT "1" LEVEL VDD -1.02V min. no load LOAD PECL SEE OUTLINE DRAWINGS PIN CONNECTION 10 ms max. START-UP TIME 25 ps max. PERIOD JITTER RMS OTHER PARAMETERS ARE AVAILABLE ON REQUEST / CREATE HERE YOUR SPECIFICATION PART NUMBERING SYSTEM EXAMPLE SERIES FREQUENCY STABILITY TEMPERATURE RANGE SYMMETRY COMPLEMENTARY OUTPUT PIN CONFIGURATION FREQUENCY M6502-25-W-S-C-G-155.520MHz M6502 BLANK FOR 100 PPM ANY 50 ~ 15 PPM BLANK FOR 0/+70°C N = -10/+60°C M = -20/+70°C W = -40/+85°C BLANK FOR 40/60% S FOR 45/55% BLANK PIN 1 NOT CONNECTED C FOR COMPLEMENTARY OUTPUT BLANK FOR DIP G FOR GULL WING REQUIRED FREQUENCY PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected] PETERMANN TECHNIK Time & Frequency Components OUTLINE DRAWING OF M6502 OUTLINE DRAWING OF M6502 GULL WING 1.14 7.62 13.1max #7(Grounded to the Case) #1 #14 15.24 #8 20.4max 7.62+0.1 - 20.57max 7.62+0.1 - #8 15.24+0.1 - 4-00.55max #7 5.08max 0.8 6.1max 5.3max 14.98+0.2 7.49+0.1 - 0.63+0.1 TYP(4 PLACES) 1.35+0.1 #14 #1 14.98+0.2 - 12.95max Unit: mm PIN Connection #1 NC/OUTPUT#2 GND #7 Output #1 #8 VDD #14 Unit:mm TEST CIRCUIT FOR PECL + + POWER SUPPLY - mA M PECL OUTPUT WAVE FORM TEST POINT #14 + VM - Logic 1 VOH 80% #8 VDD OUT1 OSCILLATOR 0,1µF OUT2 GND #1 Output Crossing #7 TEST POINT 20% VOL Symmetry PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected]