(888) IPD-CONVerters ● (888) 473-2668 ● www.ipdconverters.com HBD SERIES - DUAL OUTPUT, 60 WATT DESCRIPTION FEATURES HBD dual output, DC/DC converters feature high efficiency, 1500 VDC isolation, and open-frame packaging. The HBD family allows board designers to deliver any combination of power from either output, up to each model’s maximum rating. The HBD is available in 5V/3.3V or 3.3V/2.5V combinations in either a 24V or 48V input version. The HBD uses planar magnetics and has an MTBF of over a million hours. • • • • • Independent Dual Outputs • Independent Trim Flexible Load Sharing For Each Output High Efficiency Topology • 1500V Isolation Open-Frame Design • 100°C Baseplate Planar Magnetics Operation Efficiency vs. Load (24V Input) 85 EFFICIENCY % 80 TECHNICAL SPECIFICATIONS 75 HBD060YGE-A 70 EFF. (18V) EFF. (24V) EFF. (36V) 65 Input 60 Voltage Range 24 VDC Nominal 48 VDC Nominal Reflected Ripple Input Reverse Voltage Protection 10 18.00 - 36.00 VDC 34.00 - 75.00 VDC 80 mA Shunt Diode 40 50 60 70 80 90 100 Efficiency vs. Load (48V Input) 85 ±1% 0.2% Vout 1.0% Vout 0.5% Vout 1.0% Vout 10% Iout Rated 25% Iout 4% Vout 500 µs ±10% 110 - 140% 115 - 140% Vout Nom. 80 EFFICIENCY % 75 70 HBD060ZGE-A 65 HBD040ZGE-A 60 HBD040ZED-A 55 50 10 20 30 40 50 60 70 80 90 100 LOAD % General Turn-On Time Remote Shutdown Switching Frequency Isolation Input - Output Input - Case Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Thermal Shutdown Range Humidity Max., Non-Condensing Vibration, 3 Axes, 5 Min Each MTBF† (Bellcore TR-NWT-000332) Safety Weight (approx.) 30 LOAD % Output Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated, Output 1 Line Regulation Vin Min. - Vin Max., Iout Rated, Output 2 Load Regulation Iout Min. - Iout Max., Vin Nom., Output 1 Load Regulation Iout Min. - Iout Max., Vin Nom., Output2 Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range (5V/3.3V Units) Power Limit Threshold Range, % of Iout Rated OVP Trip Range (Main Ouput) 20 10 ms Positive Logic 500 kHz 1500 VDC 1050 VDC 500 VDC 0.03%/°C -40 To +100°C -40 To +125°C 105 To 115°C 95% 5g 6 1.3 x 10 Hrs UL, CUL, VDE 2.4 oz 1 Notes 1 For negative logic, add suffix “N” to model number. † MTBF predictions may vary slightly from model to model. Specifications typically at 25°C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with commercial wave-soldering equipment. Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. HBD SERIES - DUAL OUTPUT, 60 WATT MODELS - (See the last page of this file for options.) Vin (Volts) Vin Range (Volts) Iin Max.* (Amps) Vout (Volts) Iout Rated (Amps) Ripple & Noise Pk-Pk (mV) Efficiency Typ. ** Model 24 24 24 48 48 48 18 - 36 18 - 36 18 - 36 34 - 75 34 - 75 34 - 75 2.89 4.54 3.02 1.51 1.62 2.27 3.3/2.5 5.0/3.3 5.0/3.3 5.0/3.3 3.3/2.5 5.0/3.3 12/15 12/15 8/12 8/12 12/15 12/15 75/75 100/75 100/75 100/75 75/75 100/75 75% 78% 80% 80% 75% 79% HBD040YED-A HBD060YGE-A HBD040YGE-A HBD040ZGE-A HBD040ZED-A HBD060ZGE-A Denotes advanced product release. Consult factory for product availability. * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. Note: Current can be drawn from either output to its maximum value, or from both outputs to a combined total of 15A. MECHANICAL DRAWING 0.18" 2.28" (4.6mm) (57.9mm) MOUNTING INSERTS M3X.5 THROUGH 4PL 1.700"(43.2mm) 1.400"(35.6mm) 1 1.000"(25.4mm) 2 5 1.500"(38.1mm) 6 1.200"(30.5mm) 7 0.900"(22.9mm) 8 0.500"(12.7mm) 9 0.200"(5.1mm) BOTTOM VIEW DIA 0.040" (1.0mm) 2.40" (61.0mm) 0.400"(10.2mm) 3 0 4 -0.100"(-2.5mm) 10 -0.300"(-7.6mm) -0.50"(-12.7mm) .025" REF. -0.19" 0 1.900" Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 6.6 5.7 4.2 3.1 2.6 °C/W °C/W °C/W °C/W °C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. (0.6mm) (48.3mm) (-4.8mm) Pin Function 1 2 3 4 5 6 7 8 9 10 -Vin Case On/Off +Vin +Vout 2 - Vout 2 Trim 2 +Vout 1 -V out 1 Trim 1 2 0.50" (12.7mm) Tolerances Inches: .XX ± 0.020 .XXX ± 0.010 Pin: ± 0.002 (Millimeters) .X ± 0.5 .XX ± 0.25 ± 0.05 (Dimensions as listed unless otherwise specified.) OPTIONS When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add them to the model number. Example ordering options are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, LES, QBS, QES, TES, TQD Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES Terminal Strip TS REMARKS TTL “Low” Turns Module ON TTL “High” Turns Module OFF XWS, XWD, XWT Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES Current Share 4 SMS Headerless Y Encapsulated EWS, IWS, OWS PIN LENGTH AND HEATSINK OPTIONS Standard Pin Length is 0.180” (4.6mm) 0.110” (2.8mm) Pin Length 8 All Units (Except SMS) 0.150” (3.8mm) Pin Length 9 All Units (Except SMS) 0.24” (6.1mm) Horizontal Heatsink 1H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.24” (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.45” (11.4mm) Horizontal Heatsink 2H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.45” (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.95” (24.1mm) Horizontal Heatsink 3H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.95” (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and 0.95” vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length. NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 3