POWER-SYSTEMS CXA-L10A

DC-AC INVERTER UNIT
CXA-L10A (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
(STANDARD)
DESCRIPTION :
TDK DC/AC Inverter, CXA-series, are low-noise, high
frequency power sources developed for driving Cold Cathode
Fluorescent Lamps operating at 20~80 kHz. These inverters
are designed to handle a wide range of lamp characteristics.
FEATURES :
Constant current output ensures compatibility with a
wide range of discharge lamps.
High efficiency resonant circuitry produces low-noise,
sinusoidal-wave output.
One-lamp/two-lamp combined-use capability allows use
in four different configurations.
Common ground or floating bulb configurations.
Compact size and light weight facilitate PC board
mounting.
High Efficiency (80%)
Fuse protection
TEMPERATURE & HUMDITY :
Operating Temperature Range -10 °C ~ +60°C
Storage Temperature Range
-20 °C ~ +85°C
Humidity
95 %RH max (No dew)
DIMENSIONS :
(Bottom View)
(Side View)
21Max
16.5±0.2
15.24±0.2
(1.0)
2
3
5
7.5±0.2
44Max
38.1±0.2
5.08±0.2
(9)
(5)
3-φ1.6±0.15
26±0.2
1
Unit :
mm
Weight : 11.2 (g) typ.
5Min 13Max
4
Jumper (*1)
0.5±0.2
R1.15±0.2
5-φ0.8±0.1 or 5- 0.64±0.07
(Solder plated obstinate copper wire)
*1 Remove for Isolated
Ground
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 1 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-L10A (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
(STANDARD)
CONNECTOR CONFIGURATION:
ABSOLUTE MAXIMUM RATINGS:
Pin No. Symbols
5V
Items
Input Voltage
Symbols
Vin
Specification
0~6.0
Unit
VDC
Output Power
Pout
4.5
W
Ratings
Vin
1
2
GND
0V
3
OUT1
300Vrms
4
OUT2
300Vrms
5
OUT GND
0V
ELECTRICAL CHARACTERISTICS:
Conditions
Specification
Items
Symbols
Output
Current
Iout
Input Current
Iin
5±0.25
-10~60
Frequency
F
5±0.25
-10~60
Open Circuit
Voltage
Vopen
5±0.25
-10~60
∞
Output
Current
Iout
Input Current
Iin
5±0.25
-10~60
Frequency
Open Circuit
Voltage
F
5±0.25
-10~60
Vopen
5±0.25
-10~60
∞
Vin [V]
Ta [°C]
RL [K
Min.
Typ.
Max.
Unit
5±0.05
23±5
30
9
10
11
5±0.25
-10~60
23~37
8
10
12
23~37
-
800
1200
mA DC
23~37
25
30
35
kHz
800
900
-
Vrms
mArms
5±0.05
23±5
50
5.2
6
6.6
5±0.25
-10~60
38~62
4.6
6
7.2
38~62
-
510
770
mA DC
38~62
30
35
40
kHz
800
900
-
Vrms
23±5
60
4.5
5
5.6
5±0.25
-10~60
45~75
4.0
5
6.1
45~75
-
450
680
mA DC
45~75
25
30
35
kHz
∞
800
900
-
Vrms
23±5
60
4.5/4.5
5/5
5.5/5.5
-10~60
45~75
4/4
5/5
6/6
45~75
-
800
1200
mA DC
45~75
25
30
35
kHz
800
900
-
Vrms
Iout
Input Current
Iin
5±0.25
-10~60
Frequency
Open Circuit
Voltage
F
5±0.25
-10~60
Vopen
5±0.25
-10~60
Output
Current
Iout1 /
Iout2
5±0.05
5±0.25
Input Current
Iin
5±0.25
-10~60
Frequency
Open Circuit
Voltage
F
5±0.25
-10~60
Vopen
5±0.25
-10~60
∞
1
mArms
5±0.05
Output
Current
Connection
2
mArms
3
mArms
4
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 2 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-L10A (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
(STANDARD)
APPLICATION:
Connection 1
Connection 3
Pin 1 (Vin)
Vin
Pin 3(Iout1)
Pin 1 (Vin)
CCFL
RL
Pin 4(Iout2)
Vin
CCFL
RL
Pin 4(Iout2)
Pin 2(GND) Pin 5(Iout-ret)
Pin 2(GND) Pin 5(Iout-ret)
Connection 2
Connection 4
Pin 1 (Vin)
Vin
Pin 3(Iout1)
Pin 3(Iout1)
Pin 1 (Vin)
CCFL
RL
Pin 4(Iout2)
Vin
Pin 3(Iout1)
Pin 4(Iout2)
Pin 2(GND) Pin 5(Iout-ret)
CCFL2
RL
CCFL1
RL
Pin 2(GND) Pin 5(Iout-ret)
Note 1.
For circuit connection, please prefer to test circuit diagram.
Note 2.
Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any
conductors. Please refer to mechanical drawing for marking of high voltage area.
Note 3.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the
reading at the output connector would be less than the actual value.
Note 4.
If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily
specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal
operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor.
Note 5.
For operation in floating mode, please remove jumper (J1) on top side of PCB that pin2 and pin5.
Note 6.
To prevent electrical discharge from high voltage area, please use non-conductive fastener in U mounting
hole.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 3 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-L10A (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
(STANDARD)
TEST CIRCUIT:
Connection
Test circuit
lin
A
(1) Vin
Notes
OUT1 (3)
V Vin
OUT2(4)
1
RL
Short of OUT 1,OUT2
(2)GND
OUT GND(5)
1000:1
lin
A
(1) Vin
A
lout
V
OUT1 (3)
V Vin
OUT2 (4)
NC
OUT GND(5)
A
2
RL
Open of OUT 2
(2) GND
1000:1
lin
A
(1)Vin
lout
V
OUT1 (3)
V Vin
RL
OUT2(4)
3
Short of OUT2,OUT GND
(2) GND
OUT GND(5)
1000:1
lin
A
(1)Vin
A
lout
V
OUT1(3)
A Vin
OUT2 (4)
4
(2)GND
OUT GND(5)
1000:1
V
RL1
lout2
A
RL2
A
lout1
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 4 / 4 )
VER, 04 October 2002