POWER-SYSTEMS PS

DC-AC INVERTER UNIT
PS-M05D05(S) (5 W DUAL OUTPUTS)
(STANDARD)
DESCRIPTION :
This DC/AC Inverter is developed for alternative Backlight Inverter to Endicot ESerie. The Inverter has PCB mounting pins. The nominal input voltage is 5.0 Vdc
regulated.
Please contact us for confirmation regarding compatibility with your display.
APPLICABLE LCD:
Lamp Voltage 500 Vrms
Lamp Current 2 x 5.0 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 5.0 Vdc)
FEATURES :
min. 75% Efficiency
Input Voltage, must be regulated
Ext. PWM (TTL) Dimming Function 250 Hz
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
LxBxH
32 x 40 x 15 mm
7.62
Bottom View
17.7
8
6.10
7.62
DIMENSIONS :
-10°C ~ +60°C
-20°C ~ +85°C
95 %RH max
2
PCB mounting pins 0.64 square.
Unit : mm
Weight :12 (g) typ
1
27.94
39.70
6
32.0
3
15.24
5
4
10.16
5.60
20.23
Pin Terminal:
Pin No.
1
2
3
4
5
Symbols
Vin
GND
Vlow
Vhigh1
Vhigh2
Ratings
4.75 ~ 5.25 Vdc
(GND)
500 Vrm s (5.0 m Arm s )
500 Vrm s (5.0 m Arm s )
6
Ext. PWM
High Activ (250 Hz)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.3 , 12th February 2010
DC-AC INVERTER UNIT
PS-M05D05(S) (5 W DUAL OUTPUTS)
(STANDARD)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Note 2:
Vin (V)
5±0.25
5±0.12
5±0.25
5±0.25
5±0.25
Conditions
Ext.
Tu (°C)
PW M (%)
100
-10 ~ +60
10
-10 ~ +60
100
-10 ~ +60
100
-10 ~ +60
100
-10 ~ +60
Specification
Min.
Typ.
Max.
4.0
27
-
5.0
10
0.4
32
1.500
6.0
37
-
Unit
Note
m Arm s
%
Adc
kHz
Vrm s
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is normally at 250 Hz, and minimizes the interference disturbances of the vertical sync.
frequency.
TEST CIRCUIT :
F
Vin
4.75 ~ 5.25 V
A
1000:1
PROBE
F
V
~
Vopen
Iin
Pin 1
Pin 5
V
Pin 2
T1
Pin 4
RL2
RL1
CL2
A
~
Iout2
CL1
A
~
Iout1
Pin 6
Ext. PWM*
0/5V
Pin 3
*) Only active when Vrmt is 0 Vdc or floating
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.3 , 12th February 2010