SECOS D4KB2

D4KB05 ~ D4KB10
Voltage 50V ~ 1000V
4.0Amp Glass Passivited Bridge Rectifiers
Elektronische Bauelemente
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
D3K
FEATURES
Glass passivated chip junction
High case dielectric strength
High surge current capability
ldeal for printed circuit boar
MECHANICAL DATA
Case: UL-94 Class V-0 recognized Flane
Retardant Epoxy
Terminals: Plated leads solderable per
MIL-STD-202E, Method 208C
Polarity: Polarity symbol marked on body
Mounting position: Any
REF.
A
B
C
D
E
Millimeter
Min.
Max.
13.5
14.1
10.5
11.1
11.7
12.3
1.45 TYP.
1.2
1.4
REF.
J
K
L
M
N
Millimeter
Min.
Max.
3.51
4.11
0.66
0.86
2.4
2.8
1.0
1.4
3.1
3.4
F
G
11.7
12.3
O
6.4
7.0
P
1.8
0.6 TYP.
2.4
H
I
1.1
1.5
Q
0.4
0.6
1.05
1.25
R
2.9
3.3
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Part Number
Parameter
Symbol
D4K
B05
D4K
B1
D4K
B2
D4K
B4
D4K
B6
D4K
B8
D4K
B10
Unit
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Bridge Input Voltage
VRMS
35
70
140
280
420
560
700
V
DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
V
Maximum Average Forward Rectified Current
@TA=138°C (with heatsink)
Peak Forward Surge Current 8.3 ms Single Half
Sine-Wave Super Imposed on Rated Load
(JEDEC Method)
Maximum Forward Voltage Drop Per Bridge
Element at 4.0A Peak
I2 t Rating for Fusing (t<8.3ms)
Maximum Reverse Current at
Rated DC Blocking Voltage per
Element
A
IFSM
125
A
VF
1.1
V
I2 t
64.84
A2s
10
µA
500
µA
IR
TA=125°C
Operating and Storage temperature range
2-Jun-2011 Rev. A
4.0
TA=25°C
Typical Thermal Resistance
http://www.SeCoSGmbH.com/
I(AV)
RθJA
55
RθJC
1.5
RθJL
15
TJ, TSTG
-55~150
°C / W
°C
Any changes of specification will not be informed individually.
Page 1 of 2
D4KB05 ~ D4KB10
Elektronische Bauelemente
Voltage 50V ~ 1000V
4.0Amp Glass Passivited Bridge Rectifiers
RATINGS AND CHARACTERISTIC CURVES
http://www.SeCoSGmbH.com/
2-Jun-2011 Rev. A
Any changes of specification will not be informed individually.
Page 2 of 2