SR3 Series Stealth Microwave’s 19 inch rack mount housings are designed to fit any of Stealth’s current models. The SR3 Series adds many benefits over our standard module format. LEDs on the front panel monitor normal operation, thermal or power cautions, and alarms for thermal shutdown, amplifier, VSWR, and fan failures. The SR series comes standard with a USER PORT (DB15) which provides TTL signals to monitor the amplifier’s status. The User Port provides analog voltages to indicate the forward and reflected power levels at the output of the unit and also provides amplifier status and alarm conditions. An RS-232 interface that performs the functions of the USER PORT is also available. Features • LED amplifier status and alarm display • Built in AC or DC power supplies • Forced air cooling with hot swappable fans • On/off control via a BNC connector • DB15 Monitoring/control connection standard Options • RS-232 interface • Gain Control Environmental Characteristics Operating Temperature (Ambient): 0o C to 40o C Humidity: 95% relative without condensation Altitude: 30,000 ft. Physical Characteristics Size: 19.0” W x 16” L x 5.25” H RF Connectors: N-Type Female Weight: 23 lbs. 1007 Whitehead Road Ext., Trenton, NJ 08638 Tel: (609) 538-8586 ♦ Fax: (609) 538-8587 Email: [email protected] ♦ Web site: www.stealthmicrowave.com SR3 Series FRONT PANEL DETAIL STATUS PWR ON/OFF BYPASS ALARMS OVER PWR OVER TEMP THERMAL TRIP AMP VSWR FAN Front Panel LED Description PWR ON/OFF Line power switched on Amplifier is turned on. If amplifier has shut off due to OVER TEMP condition, LED will remain off until module reaches safe temperature OVER TEMP Amplifier’s temperature exceeds + 65 °C THERMAL TRIP Amplifier’s temperature exceeds + 75 °C. The unit is shut off and will not turn back on until its temperature drops below + 65 °C AMP Amp failure. VSWR Excessive output VSWR. Possible antenna problem. FAN Fan failure. The fan is either locked or not connected to power. 1007 Whitehead Road Ext., Trenton, NJ 08638 Tel: (609) 538-8586 ♦ Fax: (609) 538-8587 Email: [email protected] ♦ Web site: www.stealthmicrowave.com SR3 Series REAR PANEL DETAIL F2 RF OUT RF IN LINE _ F1 AMP CNTL RF SAMPLE USER PORT Label Function RF OUT 50Ω RF output. Refer to attached module data sheet for max output value RF IN RF SAMPLE 50Ω RF input. Refer to attached module data sheet for max input value When equipped, a sample output. Refer to module data sheet for dBr value F1 Fan 1 power connector (12VDC) F2 Fan 2 power connector (12VDC) RS-232 9 Pin D-Sub for RS232 monitoring / control (optional). Details below USER PORT 15 Pin D-Sub for analog monitoring / control. Details below AMP CNTL BNC Connector for TTL on/off control of rack LINE Main on/off 1007 Whitehead Road Ext., Trenton, NJ 08638 Tel: (609) 538-8586 ♦ Fax: (609) 538-8587 Email: [email protected] ♦ Web site: www.stealthmicrowave.com O RS-232 SR3 Series USER PORT Pin definitions (DB15 connector on back panel) Pin Name Description 1 AMP STATUS 2 OVRPWR 3 OVRTEMP 4 THERMAL 5 AMP 6 VSWR 7 FAN 8 SUMMARY H – Amplifier is off L – Amplifier is on H – Normal operation L – Amplifier is operating over + 49.5 dBm CW H – Normal operation L – Amplifier temperature is over + 60-65 °C H – Normal operation L – Amplifier has shut down due to excessive temperature ( > + 70-75 °C ) H – Normal operation L – Amplifier failure H – Normal operation L – Excessive output VSWR. Possible antenna problem. H – Normal operation L – Fan failure. The fan is either locked or not connected to power. H – No alarms L – One or more alarms present 9 10 11 12 13 14 15 GND FWD DET REV DET GND UNUSED UNUSED UNUSED Forward power detector voltage Feature not available on this amp Factory use only – make no connection to this pin Factory use only – make no connection to this pin Factory use only – make no connection to this pin 1007 Whitehead Road Ext., Trenton, NJ 08638 Tel: (609) 538-8586 ♦ Fax: (609) 538-8587 Email: [email protected] ♦ Web site: www.stealthmicrowave.com SR3 Series OPTIONAL RS232 PORT (DB9 connector on back panel) Transmission Parameters Setting Values Baud rate 9600 Data bits 8 Start bit 1 Stop bit 1 Parity bit None Commands Note: All commands are terminated with a carriage return or a semi-colon. Command Parameters Description AMPF --- AMP ON | OFF Returns status of amplifier alarm bit. “On” indicates an over or under amplifier current condition. Mode0: “ON” – amplifier failure, “OFF” – normal condition Mode1: 1 byte, 1 – amplifier failure, 0 – normal condition Turns amplifier on/off. AMP? --- ECHO ON | OFF ECHO? --- FANF --- FWD --- M0 --- Returns amplifiers on/off status. Mode0: “ON” – amplifier on, “OFF” – amplifier off Mode1: 1 byte, 1 – amplifier on, 0 – amplifier off When turned on, transmitted characters are echoed back to the terminal. No characters are echoed when turned off. Returns echo state Mode0: “ON” – echo on, “OFF” – echo off Mode1: 1 byte, 1 – echo on, 0 – amplifier off Returns status of the fan alarm bit Mode0: “ON” – fan failure, “OFF” – normal condition Mode1: 1 byte, 1 – fan failure, 0 – normal condition Returns forward transmitted power (Not available in all amplifiers). Mode0: “0” – “1023” relative to the forward transmitted power Mode1: 2 bytes LSB first, 0 - 1023 Data mode 0. Return values sent as text (Default). M1 --- Data mode 1. Return values sent in binary form. OVRP --- Returns status of over power alarm bit. Mode0: “ON” – Amp over rated output power, “OFF” – normal condition Mode1: 1 byte, 1 – Amp over rated output power, 0 – normal condition 1007 Whitehead Road Ext., Trenton, NJ 08638 Tel: (609) 538-8586 ♦ Fax: (609) 538-8587 Email: [email protected] ♦ Web site: www.stealthmicrowave.com SR3 Series OVRT --- Returns status of over temperature alarm bit. Mode0: “ON” – Amp’s temperature over 60° C, “OFF” – normal condition Mode1: 1 byte, 1 – Amp’s temperature over 60° C, 0 – normal condition Returns reverse power (Not available in all amplifiers). Mode0: “0” – “1023” relative to the reverse power Mode1: 2 bytes LSB first, 0 - 1023 Returns amplifier alarm status byte. Mode0: Hexadecimal “00” – “FF” Mode1: 1 byte, 0-255 See below for status byte description. Returns status of summary error alarm bit. Mode0: “ON” – Alarm condition exists, “OFF” – normal condition Mode1: 1 byte, 1 – Alarm condition exists, 0 – normal condition Resets the controller. REV --- STATUS --- SUMERR --- SYSRESET --- TEMP --- Returns amplifier base plate temperature in degrees Celsius. Mode0: “xx C” Mode1: 2 bytes, LSB first THRML --- Returns status of thermal alarm bit. Occurs when amplifier exceeds 75° C Mode0: “ON” – Amp in thermal shutdown, “OFF” – normal condition Mode1: 1 byte, 1 – Amp in thermal shutdown, 0 – normal condition VER --- Displays the controller software version. VSWR --- Returns status of VSWR alarm bit (Not available in all amplifiers) Mode0: “ON” – High VSWR condition exists, “OFF” – normal condition Mode1: 1 byte, 1 – High VSWR condition exists, 0 – normal Status Byte bit 7 Fan bit 6 VSWR bit 5 Current Alarm bit 4 Thermal Shutdown bit 3 High Temperature bit 2 Over Power bit 1 Amplifier On/Off 1007 Whitehead Road Ext., Trenton, NJ 08638 Tel: (609) 538-8586 ♦ Fax: (609) 538-8587 Email: [email protected] ♦ Web site: www.stealthmicrowave.com bit 0 Summary Error