VECTRON TFR390

Tfr390.doc
version 1.0
VI TELEFILTER
Resonator Specification
13.06.01
TFR 390
- 1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
for input:
for output:
23 °C
0 dBm
50 Ω || 0 pF
50 Ω || 0 pF
Characteristics
Remark:
The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fR is the frequency of the minimum of the
passband attenuation amin. The temperature coefficient of frequency TRF is valid both for the resonant frequency fR and the frequency response of
the resonator in the operating temperature range. The frequency shift of the resonator in the operating temperature range is not included in the
production tolerance scheme.
Data
typ. value
Insertion Loss
(Reference level)
ae = amin
Resonant Frequency
fR
Ageing of Resonant Frequency
1,6
dB
tolerance/limit
max. 2,5
± 100
390,000 MHz
10
ppm
Unloaded Quality Factor
Parallel Capacitance
C0
3,6
pF
Motional Resistance
R1
14,0
Ω
Motional Inductance
L1
70,5
µH
Motional Capacitance
C1
2,37
max.
10
min.
6000
dB
kHz
ppm/year
fF
Operating Temperature Range
- 40..... + 85
°C
Storage Temperature Range
- 40..... + 85
°C
°C
Turnover Temperature
25
Temperature Coefficent of frequency (TRF)
-0,032 ppm/K2
Frequency Deviation of fR over temperature T
Input Power Level
∆fc(Hz) = TRf(ppm/K2) x (T - TA)2x fCAT (MHz)
max. 0
dBm
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfr390.doc
version 1.0
VI TELEFILTER
Resonator Specification
TFR 390
13.06.01
- 2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
R N24
50 Ohm test circuit 1
2
2
6
6
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfr390.doc
version 1.0
VI TELEFILTER
Resonator Specification
TFR 390
13.06.01
- 3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
Shock:
random free drops 3 times from height of 1.0 meter onto concrete floor.
Vibration:
Total peak amplitude:
Vibration frequency :
Sweep period
:
Vibration directions :
Duration :
Solderability:
( solder heat )
immersed pad in soldering bath at 245 ± 5°C for 5 ± 0.5 seconds.
!75% or more of the immersed surface shall be covered with solder
Temperature Characteristics:
Dry heat:
( Aging test )
Specimens shall be measured within -10°C to +50°C temperature range
Temperature
:
125 ± 2°C
Duration :
250 hours
Cold resistance:
Temperature
Duration :
Thermal Shock:
Heat cycle conditions
-55 C
25 C
85 C
(30 min)
(5 min)
(30 min)
Cycle time :
5 times
1.5 mm
10 to 55 Hz
1.0 minute
3 mutually perpendicular
2 hr / direc.
:
-40 ± 3°C
96 hours
Packing
Tape (all dimensions in mm)
W
:
12
Po
:
4
± 0,1
+ 0,1
Do
:
1,5
E
:
1,75 ± 0,1
F
:
5,5 ± 0,05
G (min) :
Po
Do
P2
:
2
± 0,05
P1
:
8
± 0,10
P2
E
Ao
F
D1
W
Bo
CT
0,75
D1(min) :
EMBOSSED CARRIER TAPE
± 0,3
G
P1
1,5
Ao
:
5,30
± 0,1
Bo
:
5,30
± 0,1
CT
:
9,5
COVER TAPE
± 0,2
W 2
Reel (all dimensions in mm):
A
:
330
W1
:
W2 (max) :
N (min)
C
12,4 + 2,0
18,4
:
:
50
13
± 0.2
A
C
N
W 1
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfr390.doc
version 1.0
VI TELEFILTER
Resonator Specification
13.06.01
TFR 390
- 4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfr390.doc
version 1.0
VI TELEFILTER
Resonator Specification
13.06.01
TFR 390
- 5/5
History
version
reason of changes
name
date
1.0
generate specification
Pfeiffer
13.06.2001
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.