VI TELEFILTER
Filter Specification
14.09.00
TFS 248 D
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
source:
load:
23 °C
0 dBm
630 Ω || -5,6 pF
600 Ω || -5,7 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 248 D is the minimum of the pass band attenuation amin. This value is defined as the
insertion loss ae. The nominal frequency fN is fixed to 248,6 MHz. The given values for the relative attenuation arel and for the group delay ripple
have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the
operating temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. Value
Limit
______________________________________________________________________________________________________
Insertion Loss (at ambient temperature)
4,0 dB
ae = a0
3,0 ... 6,0 dB
drift vs. Temperature
max. ± 0,5 dB
______________________________________________________________________________________________________
248,6 MHz
Nominal Frequency
fN
______________________________________________________________________________________________________
Centre Frequency
248,6 MHz
f0
______________________________________________________________________________________________________
3 dB bandwidth
min. 240 kHz
Bw3dB
______________________________________________________________________________________________________
Passband
fN ± 95 kHz
______________________________________________________________________________________________________
Relative Attenuation
fN ± 95
kHz
fN ± 95
kHz ... fN ± 120
arel
kHz
max.
1,2 dB
-0,9 ... +2,1 dB
fN ± 330
kHz ... fN ± 600
kHz
min. 13
dB
fN ± 600
kHz ... fN ± 800
kHz
min. 22
dB
fN ± 800
kHz ... fN ±
3
MHz
min. 30
dB
fN ±
3
MHz ... fN ± 105
MHz
min. 48
dB
fN ± 105
MHz ... fN ± 150
MHz
min. 51
dB
______________________________________________________________________________________________________
Group Delay
3
µs
GD
max.
Group Delay Ripple fN ± 95 kHz
max.
0,7 µs
fN ± 120 kHz
max.
1,0 µs
______________________________________________________________________________________________________
Input power level
max. 12
dBm
______________________________________________________________________________________________________
Operating Temperature Range
-5 °C ... + 75 °C
______________________________________________________________________________________________________
Temperature Coefficient
- 0,032 ppm/K2
TC
______________________________________________________________________________________________________
generated:
checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs248d.doc
version 2.1
VI TELEFILTER
Filter Specification
14.09.00
TFS 248 D
2/5
Construction and Pin Connection
(All dimensions in mm)
TFS 248 D
M36
Datecode
1
2
3
4
5
6
7
8
9
10
Input
Ground
Ground
Ground
Output RF-return
Output
Ground
Ground
Ground
Input RF-return
Datecode
K
L
M
...
Year+week
1998
1999
2000
Possible matching circuits
circuit 1 (Reference matching circuit for final testing at Telefilter)
L1
L2
1
Input
6
Output
SAW
50 Ohm
50 Ohm
C1
C2
2,3,4,5,7,
8,9,10
circuit 2
L1
L3
1
6
Input
Output
SAW
50 Ohm
50 Ohm
L2
L4
2,3,4,5,7,
8,9,10
circuit 3
C1
1
Input
C2
6
Output
50 Ohm
SAW
50 Ohm
L1
L2
2,3,4,5,7,
8,9,10
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs248d.doc
version 2.1
VI TELEFILTER
Filter Specification
14.09.00
TFS 248 D
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
DIN IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
: 32
± 0,3
Po
Do
:
:
4 ± 0,1
1,5 + 0,5
E
F
:
:
1,75 ± 0,1
11,5 ± 0,1
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
0,75
2 ± 0,1
12 ± 0,1
1,5
7,1 ± 0,1
Bo
Ko
t
Ct
:
:
:
1700
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Po
Do
P
2
Ko
t
E
Ao
F
D1
Ct
W
Bo
G
19.6 ± 0,1
2,1 ± 0,1
0,35 ± 0,05
:
25,5 ± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
32,4 +2
38,4
100
C
C
:
13
A
+ 0,5/-0,2
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs248d.doc
version 2.1
VI TELEFILTER
Filter Specification
TFS 248 D
14.09.00
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs248d.doc
version 2.1
VI TELEFILTER
Filter Specification
14.09.00
TFS 248 D
5/5
History
Version
Reason of Changes
Name
Date
2.1
- definition for the insertion loss changed
- passband ripple adjusted to the new loss definition
- wrong tape and reel dimensions corrected
Steiner
14.09.2000
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.