tfs360A.doc version 1.6 12.04.2001 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 360A 1/5 _____________________________________________________________________________________________________ Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedances for input: 360 Ω // - 1,05 pF for output: 360 Ω // - 1,05 pF Coupling coil: 91 nH Characteristics Remark: Reference level for the relative attenuation arel of the TFS 360 A is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 1.5 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 360 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo. Data typ. value tolerance/limit _____________________________________________________________________________________________________ Insertion loss ae = amin max. 5,0 dB (Reference level) _____________________________________________________________________________________________________ Nominal frequency 360,00 MHz fN _____________________________________________________________________________________________________ Pass band ripple fN ± 67,7kHz BW max. 1,5 dB _____________________________________________________________________________________________________ Relative attenuation arel fN ± 0,4 MHz…fN ± 0,6 MHz min. 29 dB fN ± 0,6 MHz…fN ± 0,8 MHz min. 42 dB fN ± 0,8 MHz…fN ± 1,6 MHz min. 50 dB fN ± 1,6 MHz…fN ± 3,0 MHz min. 45 dB fN ± 3,0 MHz…fN ± 115 MHz min. 52 dB _____________________________________________________________________________________________________ Group delay ripple GD fN ± 67,76 kHz max. 2,0 µs _____________________________________________________________________________________________________ Input power level max. 10 dBm _____________________________________________________________________________________________________ - 20 °C ... + 75 °C -35 °C …+ 85 °C Operating temperature range Storage temperature __________________________________________________________________________________________ Temperature coefficient of frequency TC ca. - 0.036 ppm/K² __________________________________________________________________________________________ Frequency inversion temperature + 20 °C _____________________________________________________________________________________________________ Generated: Checked / approved: VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs360A.doc version 1.6 12.04.2001 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 360A 2/5 _____________________________________________________________________________________________________ Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) 5 7 360A M11 3 1 Pin 1 Pin 2 Pin 3 Pin 4 Sym. Output Sym. Output External Coil Package Ground Pin 5 Pin 6 Pin 7 Pin 8 Sym. Input Sym. Input Ground Package ground 50 Ohm Test circuit 1 LB-IN L1 6 SAW C1 LB-OUT C2 2 5 L2 L3 1 L4 3 L5 4, 7, 8 50 Ohm Test circuit 2 C1 C3 LB-IN 6 SAW L1 LB-OUT 1 L2 2 5 C2 C4 3 4, 7, 8 L3 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs360A.doc version 1.6 12.04.2001 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 360A 3/5 _____________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) EMBOSSED CARRIER TAPE W : 12 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 Po D o P 2 E A F : o 5,5 ± 0,1 F G (min) : P2 : P1 D 0,75 13,4 2 ± 0,05 ± 0,1 : 4 D1(min) : 1,5 Ao : 5,3 ± 0,1 Bo : 5,3 ± 0,1 1 ± 0,1 B W o G P1 COVER TAPE W 2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) : : 330 12,4 +2 18,4 : 50 C C : 13 ± 0,25 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs360A.doc version 1.6 12.04.2001 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 360A 4/5 _____________________________________________________________________________________________________ Trailer 500 mm Min. Leader 500 mm Min. PIN 1 User direction of feed Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 temperature / °C 23 time / sec. 140 temperature / °C 160 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs360A.doc version 1.6 12.04.2001 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 360A 5/5 _____________________________________________________________________________________________________ 10 20 30 40 50 60 70 80 90 100 110 120 130 34 46 60 80 103 121 134 143 150 154 156 158 159 150 160 170 180 190 195 200 205 210 215 220 230 240 161 164 170 180 205 230 255 230 205 180 165 140 120 History Version Reason of Changes Name Date 1.5 Change date code from month to week Change errors in tape an reel information Remove ‘Construction and Pin Connection’ from page 1 Guarantee better values for stability characteristic Dr. Wall 17.03.2000 1.6 Tape drawing with part position added. André du Hamél 12.04.2001 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.