LM136A-2.5QML LM136A-2.5QML 2.5V Reference Diode Literature Number: SNOSAM3D LM136A-2.5QML 2.5V Reference Diode General Description Features The LM136A-2.5QML integrated circuit is a precision 2.5V shunt regulator diode. This monolithic IC voltage reference operates as a low-temperature-coefficient 2.5V zener with 0.2Ω dynamic impedance. A third terminal on the LM136A-2.5QML allows the reference voltage and temperature coefficient to be trimmed easily. The LM136A-2.5QML is useful as a precision 2.5V low voltage reference for digital voltmeters, power supplies or op amp circuitry. The 2.5V make it convenient to obtain a stable reference from 5V logic supplies. Further, since the LM136A-2.5QML operates as a shunt regulator, it can be used as either a positive or negative voltage reference. ■ Available with radiation guarantee ■ ■ ■ ■ ■ ■ 100 krad(Si) — Total Ionizing Dose 100 krad(Si) — ELDRS Free Low temperature coefficient Wide operating current of 400 μA to 10 mA Guaranteed temperature stability Easily trimmed for minimum temperature drift Fast turn-on 3–lead transistor package Ordering Information NS Part Number SMD Part Number NS Package Number LM136AH-2.5/883 Package Description H03H T0-46, 3LD Metal Can LM136AH-2.5RQV (Note 6) 5962R0050101VXA 100 krad(Si) H03H T0-46, 3LD Metal Can LM136AH-2.5RLQV (Note 7) ELDRS Free 5962R0050102VXA 100 krad(Si) H03H T0-46, 3LD Metal Can LM136-2.5 MDE (Note 7) ELDRS Free 5962R0050102V9A 100 krad(Si) (Note 1) Bare Die LM136-2.5 MDR (Note 6) 5962R0050101V9A 100 krad(Si) (Note 1) Bare Die Note 1: FOR ADDITIONAL DIE INFORMATION, PLEASE VISIT THE HI REL WEB SITE AT: www.national.com/analog/space/level_die Connection Diagram TO-46 Metal Can Package 20139720 Bottom View See NS Package Number H03H © 2010 National Semiconductor Corporation 201397 www.national.com LM136A-2.5QML 2.5V Reference Diode October 26, 2010 LM136A-2.5QML Schematic Diagram 20139701 www.national.com 2 LM136A-2.5QML Typical Applications 2.5V Reference 20139709 2.5V Reference with Minimum Temperature Coefficient 20139710 †Adjust to 2.490V *Any silicon signal diode Wide Input Range Reference 20139711 3 www.national.com LM136A-2.5QML Absolute Maximum Ratings (Note 2) Reverse Current Forward Current Storage Temperature 15 mA 10 mA −60°C ≤ TA ≤ +150°C −55°C ≤ TA ≤ +125°C +150°C 300°C Operating Temperature Range (Note 3) Maximum Junction Temperature (TJ) (Note 3) Lead Temperature (Soldering 10 seconds) Thermal Resistance θJA Still Air Flow 500LF/Min Air Flow 354°C/W 77°C/W 46°C/W θJC ESD Rating (Note 4) 1,000V Quality Conformance Inspection Mil-Std-883, Method 5005 - Group A Subgroup Description Temp°C 1 Static tests at +25 2 Static tests at +125 3 Static tests at -55 4 Dynamic tests at +25 5 Dynamic tests at +125 6 Dynamic tests at -55 7 Functional tests at +25 8A Functional tests at +125 8B Functional tests at -55 9 Switching tests at +25 10 Switching tests at +125 11 Switching tests at -55 12 Settling time at +25 13 Settling time at +125 14 Settling time at -55 www.national.com 4 DC Parameters The following conditions apply, unless otherwise specified. Symbol IAdj ΔVZ Parameter Adjust Current Delta Zener Voltage IR = 1mA Conditions Notes VAdj = 0.7V Zener Voltage Reverse Dynamic Impedance VStab Temperature Stability +125 µA 1, 2, 3 6.0 mV 1 10 mV 2, 3 -125 2.465 2.515 V 1 2.44 2.54 V 2, 3 2.39 2.49 V 1 2.29 2.49 V 2, 3 2.49 2.69 V 1, 2, 3 (Note 5) 0.6 Ω 1 (Note 5) 1.0 2, 3 18 Ω mV Min Max Unit Subgroups VAdj = Open −10 +10 mV 1 VAdj = 0.7V −10 +10 mV 1 VAdj = 1.9V −10 +10 mV 1 VAdj = 0.7V VAdj = 1.9V ZRD Subgroups Max 0.4mA ≤ IZ ≤ 10 mA VAdj = Open VZ Unit Min VZ = Adjusted to 2.490V 2, 3 DC Drift Parameters Delta calculations are performed on QMLV devices at Group B, Subgroup 5 only. Symbol VZ Parameter Zener Voltage Conditions Notes Note 2: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 3: The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature), θJA (package junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any temperature is PDmax = (TJmax - TA)/ θJA or the number given in the Absolute Maximum Ratings, whichever is lower. Note 4: Human body model, 1.5KΩ in series with 100pF. Note 5: Parameter tested go-no-go only. Note 6: Pre and post irradiation limits are identical to those listed under DC electrical characteristics. These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effect. Radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in Mil-Std-883, Method 1019. Note 7: Low dose rate testing has been performed on a wafer-by-wafer basis, per test method 1019 condition D of MIL-STD-883, with no enhanced low dose rate sensitivity (ELDRS) effect. 5 www.national.com LM136A-2.5QML LM136A-2.5QML Electrical Characteristics LM136A-2.5QML Typical Performance Characteristics Reverse Voltage Change Zener Noise Voltage 20139722 20139721 Dynamic Impedance Response Time 20139724 20139723 Reverse Characteristics Forward Characteristics 20139725 www.national.com 20139726 6 LM136A-2.5QML Temperature Drift 20139728 FIGURE 1. LM136 With Pot for Adjustment of Breakdown Voltage (Trim Range = ±120 mV typical) 20139727 Application Hints The LM136 voltage reference is much easier to use than ordinary zener diodes. It's low impedance and wide operating current range simplify biasing in almost any circuit. Further, either the breakdown voltage or the temperature coefficient can be adjusted to optimize circuit performance. Figure 1 shows an LM136 with a 10k potentiometer for adjusting the reverse breakdown voltage. With the addition of R1 the breakdown voltage can be adjusted without affecting the temperature coefficient of the device. The adjustment range is usually sufficient to adjust for both the initial device tolerance and inaccuracies in buffer circuitry. If minimum temperature coefficient is desired, two diodes can be added in series with the adjustment potentiometer as shown in Figure 2. When the device is adjusted to 2.490V the temperature coefficient is minimized. Almost any silicon signal diode can be used for this purpose such as a 1N914, 1N4148 or a 1N457. For proper temperature compensation the diodes should be in the same thermal environment as the LM136. It is usually sufficient to mount the diodes near the LM136 on the printed circuit board. The absolute resistance of R1 is not critical and any value from 2k to 20k will work. 20139729 FIGURE 2. Temperature Coefficient Adjustment (Trim Range = ±70 mV typical) Low Cost 2 Amp Switching Regulator† 20139705 *L1 60 turns #16 wire on Arnold Core A-254168-2 †Efficiency ≈ 80% 7 www.national.com LM136A-2.5QML Precision Power Regulator with Low Temperature Coefficient 20139713 5V Crowbar Trimmed 2.5V Reference with Temperature Coefficient Independent of Breakdown Voltage 20139715 *Does not affect temperature coefficient 20139714 Adjustable Shunt Regulator 20139706 www.national.com 8 LM136A-2.5QML Linear Ohmmeter 20139716 Op Amp with Output Clamped Bipolar Output Reference 20139717 20139718 9 www.national.com LM136A-2.5QML 2.5V Square Wave Calibrator 20139719 5V Buffered Reference 20139730 Low Noise Buffered Reference 20139731 www.national.com 10 Date Released Revision 07/06/07 A New Release, Corporate format Section Changes 10/16/2010 B Data Sheet Title, General Description, Order Update with current device information and format. Information, Electrical Characteristics, Removed all references to the LM136-2.5 Non “A” Application Hints package NSID no longer offered. Added Die NSID's to data sheet. Revision A will be Archived. 11 2 MDS datasheets converted into one corporate datasheet format. MNLM136–2.5–X Rev 0A0 and MNLM136A-2.5–X-RH. The ELDRS Part has also been added. Rev. 0E0 will be archived. www.national.com LM136A-2.5QML Revision History LM136A-2.5QML Physical Dimensions inches (millimeters) unless otherwise noted NS Package Number H03H www.national.com 12 LM136A-2.5QML 13 www.national.com LM136A-2.5QML 2.5V Reference Diode Notes For more National Semiconductor product information and proven design tools, visit the following Web sites at: www.national.com Products Design Support Amplifiers www.national.com/amplifiers WEBENCH® Tools www.national.com/webench Audio www.national.com/audio App Notes www.national.com/appnotes Clock and Timing www.national.com/timing Reference Designs www.national.com/refdesigns Data Converters www.national.com/adc Samples www.national.com/samples Interface www.national.com/interface Eval Boards www.national.com/evalboards LVDS www.national.com/lvds Packaging www.national.com/packaging Power Management www.national.com/power Green Compliance www.national.com/quality/green Switching Regulators www.national.com/switchers Distributors www.national.com/contacts LDOs www.national.com/ldo Quality and Reliability www.national.com/quality LED Lighting www.national.com/led Feedback/Support www.national.com/feedback Voltage References www.national.com/vref Design Made Easy www.national.com/easy www.national.com/powerwise Applications & Markets www.national.com/solutions Mil/Aero www.national.com/milaero PowerWise® Solutions Serial Digital Interface (SDI) www.national.com/sdi Temperature Sensors www.national.com/tempsensors SolarMagic™ www.national.com/solarmagic PLL/VCO www.national.com/wireless www.national.com/training PowerWise® Design University THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION (“NATIONAL”) PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS, IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT NATIONAL’S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS. EXCEPT AS PROVIDED IN NATIONAL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other brand or product names may be trademarks or registered trademarks of their respective holders. Copyright© 2010 National Semiconductor Corporation For the most current product information visit us at www.national.com National Semiconductor Americas Technical Support Center Email: [email protected] Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Technical Support Center Email: [email protected] National Semiconductor Asia Pacific Technical Support Center Email: [email protected] National Semiconductor Japan Technical Support Center Email: [email protected] IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP® Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2011, Texas Instruments Incorporated