The LM136A-2.5QML integrated circuit is a precision 2.5V
shunt regulator diode. This monolithic IC voltage reference
operates as a low-temperature-coefficient 2.5V zener with
0.2Ω dynamic impedance. A third terminal on the
LM136A-2.5QML allows the reference voltage and temperature coefficient to be trimmed easily.
The LM136A-2.5QML is useful as a precision 2.5V low voltage reference for digital voltmeters, power supplies or op amp
circuitry. The 2.5V make it convenient to obtain a stable reference from 5V logic supplies. Further, since the
LM136A-2.5QML operates as a shunt regulator, it can be
used as either a positive or negative voltage reference.
■ Available with radiation guarantee
■
■
■
■
■
■
100 krad(Si)
— Total Ionizing Dose
100 krad(Si)
— ELDRS Free
Low temperature coefficient
Wide operating current of 400 μA to 10 mA
Guaranteed temperature stability
Easily trimmed for minimum temperature drift
Fast turn-on
3–lead transistor package
Ordering Information
NS Part Number
SMD Part Number
NS Package Number
LM136AH-2.5/883
Package Description
H03H
T0-46, 3LD Metal Can
LM136AH-2.5RQV (Note 6)
5962R0050101VXA
100 krad(Si)
H03H
T0-46, 3LD Metal Can
LM136AH-2.5RLQV (Note 7)
ELDRS Free
5962R0050102VXA
100 krad(Si)
H03H
T0-46, 3LD Metal Can
LM136-2.5 MDE (Note 7)
ELDRS Free
5962R0050102V9A
100 krad(Si)
(Note 1)
Bare Die
LM136-2.5 MDR (Note 6)
5962R0050101V9A
100 krad(Si)
(Note 1)
Bare Die
Note 1: FOR ADDITIONAL DIE INFORMATION, PLEASE VISIT THE HI REL WEB SITE AT: www.national.com/analog/space/level_die
Connection Diagram
TO-46
Metal Can Package
20139720
Bottom View
See NS Package Number H03H
© 2010 National Semiconductor Corporation
201397
www.national.com
LM136A-2.5QML 2.5V Reference Diode
October 26, 2010
LM136A-2.5QML
Schematic Diagram
20139701
www.national.com
2
LM136A-2.5QML
Typical Applications
2.5V Reference
20139709
2.5V Reference with Minimum
Temperature Coefficient
20139710
†Adjust
to 2.490V
*Any silicon signal diode
Wide Input Range Reference
20139711
3
www.national.com
LM136A-2.5QML
Absolute Maximum Ratings (Note 2)
Reverse Current
Forward Current
Storage Temperature
15 mA
10 mA
−60°C ≤ TA ≤ +150°C
−55°C ≤ TA ≤ +125°C
+150°C
300°C
Operating Temperature Range (Note 3)
Maximum Junction Temperature (TJ) (Note 3)
Lead Temperature (Soldering 10 seconds)
Thermal Resistance
θJA
Still Air Flow
500LF/Min Air Flow
354°C/W
77°C/W
46°C/W
θJC
ESD Rating (Note 4)
1,000V
Quality Conformance Inspection
Mil-Std-883, Method 5005 - Group A
Subgroup
Description
Temp°C
1
Static tests at
+25
2
Static tests at
+125
3
Static tests at
-55
4
Dynamic tests at
+25
5
Dynamic tests at
+125
6
Dynamic tests at
-55
7
Functional tests at
+25
8A
Functional tests at
+125
8B
Functional tests at
-55
9
Switching tests at
+25
10
Switching tests at
+125
11
Switching tests at
-55
12
Settling time at
+25
13
Settling time at
+125
14
Settling time at
-55
www.national.com
4
DC Parameters
The following conditions apply, unless otherwise specified.
Symbol
IAdj
ΔVZ
Parameter
Adjust Current
Delta Zener Voltage
IR = 1mA
Conditions
Notes
VAdj = 0.7V
Zener Voltage
Reverse Dynamic Impedance
VStab
Temperature Stability
+125
µA
1, 2, 3
6.0
mV
1
10
mV
2, 3
-125
2.465 2.515
V
1
2.44
2.54
V
2, 3
2.39
2.49
V
1
2.29
2.49
V
2, 3
2.49
2.69
V
1, 2, 3
(Note 5)
0.6
Ω
1
(Note 5)
1.0
2, 3
18
Ω
mV
Min
Max
Unit
Subgroups
VAdj = Open
−10
+10
mV
1
VAdj = 0.7V
−10
+10
mV
1
VAdj = 1.9V
−10
+10
mV
1
VAdj = 0.7V
VAdj = 1.9V
ZRD
Subgroups
Max
0.4mA ≤ IZ ≤ 10 mA
VAdj = Open
VZ
Unit
Min
VZ = Adjusted to 2.490V
2, 3
DC Drift Parameters
Delta calculations are performed on QMLV devices at Group B, Subgroup 5 only.
Symbol
VZ
Parameter
Zener Voltage
Conditions
Notes
Note 2: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 3: The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature), θJA (package
junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any temperature is PDmax = (TJmax - TA)/
θJA or the number given in the Absolute Maximum Ratings, whichever is lower.
Note 4: Human body model, 1.5KΩ in series with 100pF.
Note 5: Parameter tested go-no-go only.
Note 6: Pre and post irradiation limits are identical to those listed under DC electrical characteristics. These parts may be dose rate sensitive in a space
environment and may demonstrate enhanced low dose rate effect. Radiation end point limits for the noted parameters are guaranteed only for the conditions as
specified in Mil-Std-883, Method 1019.
Note 7: Low dose rate testing has been performed on a wafer-by-wafer basis, per test method 1019 condition D of MIL-STD-883, with no enhanced low dose
rate sensitivity (ELDRS) effect.
5
www.national.com
LM136A-2.5QML
LM136A-2.5QML Electrical Characteristics
LM136A-2.5QML
Typical Performance Characteristics
Reverse Voltage Change
Zener Noise Voltage
20139722
20139721
Dynamic Impedance
Response Time
20139724
20139723
Reverse Characteristics
Forward Characteristics
20139725
www.national.com
20139726
6
LM136A-2.5QML
Temperature Drift
20139728
FIGURE 1. LM136 With Pot for Adjustment
of Breakdown Voltage
(Trim Range = ±120 mV typical)
20139727
Application Hints
The LM136 voltage reference is much easier to use than ordinary zener diodes. It's low impedance and wide operating
current range simplify biasing in almost any circuit. Further,
either the breakdown voltage or the temperature coefficient
can be adjusted to optimize circuit performance.
Figure 1 shows an LM136 with a 10k potentiometer for adjusting the reverse breakdown voltage. With the addition of
R1 the breakdown voltage can be adjusted without affecting
the temperature coefficient of the device. The adjustment
range is usually sufficient to adjust for both the initial device
tolerance and inaccuracies in buffer circuitry.
If minimum temperature coefficient is desired, two diodes can
be added in series with the adjustment potentiometer as
shown in Figure 2. When the device is adjusted to 2.490V the
temperature coefficient is minimized. Almost any silicon signal diode can be used for this purpose such as a 1N914,
1N4148 or a 1N457. For proper temperature compensation
the diodes should be in the same thermal environment as the
LM136. It is usually sufficient to mount the diodes near the
LM136 on the printed circuit board. The absolute resistance
of R1 is not critical and any value from 2k to 20k will work.
20139729
FIGURE 2. Temperature Coefficient Adjustment
(Trim Range = ±70 mV typical)
Low Cost 2 Amp Switching Regulator†
20139705
*L1
60 turns #16 wire on Arnold Core A-254168-2
†Efficiency ≈ 80%
7
www.national.com
LM136A-2.5QML
Precision Power Regulator with Low Temperature Coefficient
20139713
5V Crowbar
Trimmed 2.5V Reference with
Temperature Coefficient Independent
of Breakdown Voltage
20139715
*Does
not affect temperature coefficient
20139714
Adjustable Shunt Regulator
20139706
www.national.com
8
LM136A-2.5QML
Linear Ohmmeter
20139716
Op Amp with Output Clamped
Bipolar Output Reference
20139717
20139718
9
www.national.com
LM136A-2.5QML
2.5V Square Wave Calibrator
20139719
5V Buffered Reference
20139730
Low Noise Buffered Reference
20139731
www.national.com
10
Date Released
Revision
07/06/07
A
New Release, Corporate format
Section
Changes
10/16/2010
B
Data Sheet Title, General Description, Order Update with current device information and format.
Information, Electrical Characteristics,
Removed all references to the LM136-2.5 Non “A”
Application Hints
package NSID no longer offered. Added Die NSID's
to data sheet. Revision A will be Archived.
11
2 MDS datasheets converted into one corporate
datasheet format. MNLM136–2.5–X Rev 0A0 and
MNLM136A-2.5–X-RH. The ELDRS Part has also
been added. Rev. 0E0 will be archived.
www.national.com
LM136A-2.5QML
Revision History
LM136A-2.5QML
Physical Dimensions inches (millimeters) unless otherwise noted
NS Package Number H03H
www.national.com
12
LM136A-2.5QML
13
www.national.com
LM136A-2.5QML 2.5V Reference Diode
Notes
For more National Semiconductor product information and proven design tools, visit the following Web sites at:
www.national.com
Products
Design Support
Amplifiers
www.national.com/amplifiers
WEBENCH® Tools
www.national.com/webench
Audio
www.national.com/audio
App Notes
www.national.com/appnotes
Clock and Timing
www.national.com/timing
Reference Designs
www.national.com/refdesigns
Data Converters
www.national.com/adc
Samples
www.national.com/samples
Interface
www.national.com/interface
Eval Boards
www.national.com/evalboards
LVDS
www.national.com/lvds
Packaging
www.national.com/packaging
Power Management
www.national.com/power
Green Compliance
www.national.com/quality/green
Switching Regulators
www.national.com/switchers
Distributors
www.national.com/contacts
LDOs
www.national.com/ldo
Quality and Reliability
www.national.com/quality
LED Lighting
www.national.com/led
Feedback/Support
www.national.com/feedback
Voltage References
www.national.com/vref
Design Made Easy
www.national.com/easy
www.national.com/powerwise
Applications & Markets
www.national.com/solutions
Mil/Aero
www.national.com/milaero
PowerWise® Solutions
Serial Digital Interface (SDI) www.national.com/sdi
Temperature Sensors
www.national.com/tempsensors SolarMagic™
www.national.com/solarmagic
PLL/VCO
www.national.com/wireless
www.national.com/training
PowerWise® Design
University
THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION
(“NATIONAL”) PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY
OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO
SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS,
IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT.
TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT
NATIONAL’S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL
PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR
APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND
APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE
NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS.
EXCEPT AS PROVIDED IN NATIONAL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO
LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE
AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY
RIGHT.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR
SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL
COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected
to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.
National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other
brand or product names may be trademarks or registered trademarks of their respective holders.
Copyright© 2010 National Semiconductor Corporation
For the most current product information visit us at www.national.com
National Semiconductor
Americas Technical
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor Europe
Technical Support Center
Email: [email protected]
National Semiconductor Asia
Pacific Technical Support Center
Email: [email protected]
National Semiconductor Japan
Technical Support Center
Email: [email protected]
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Audio
www.ti.com/audio
Communications and Telecom www.ti.com/communications
Amplifiers
amplifier.ti.com
Computers and Peripherals
www.ti.com/computers
Data Converters
dataconverter.ti.com
Consumer Electronics
www.ti.com/consumer-apps
DLP® Products
www.dlp.com
Energy and Lighting
www.ti.com/energy
DSP
dsp.ti.com
Industrial
www.ti.com/industrial
Clocks and Timers
www.ti.com/clocks
Medical
www.ti.com/medical
Interface
interface.ti.com
Security
www.ti.com/security
Logic
logic.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Power Mgmt
power.ti.com
Transportation and Automotive www.ti.com/automotive
Microcontrollers
microcontroller.ti.com
Video and Imaging
RFID
www.ti-rfid.com
OMAP Mobile Processors
www.ti.com/omap
Wireless Connectivity
www.ti.com/wirelessconnectivity
TI E2E Community Home Page
www.ti.com/video
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated