ADVANTECH ADAM-4012

ADAM-4011/4011D
ADAM-4012
ADAM-4013
Analog Input Module
RTD Input Module
ADAM-4012
ADAM-4011/4011D
Specifications
General
 LED Indicators
 Power Consumption
5-digit (ADAM-4011D)
1.2 W @ 24 VDC
Analog Input
 Input Impedance
Voltage: 2 MΩ
Current: 125 Ω
(Added by users)
 Input Types
T/C, mV, V or mA
 Input Range
±15 mV, ±50 mV, ±100
mV, ±500 mV, ±1 V,
±2.5 V, ±20 mA
 T/C Type and Temperature Range





Thermocouple Input Module
J 0 ~ 760° C
K 0 ~ 1370° C
T -100 ~ 400° C
E 0 ~ 1000° C
Input Surge Protection
NMR @ 50/60 Hz
Sampling Rate
Span Drift
Zero Drift
R
S
B
500 ~1750° C
500 ~1750° C
500 ~1800° C
Yes
100 dB
10 samples/sec.
±25 ppm/° C
±3 µV/° C
Specifications
Specifications
General
General
 Power Consumption
Analog Input
 Input Impedance
 Input Types
 Input Range
 NMR @ 50/60 Hz
 Span Drift
 Zero Drift
Digital Output
 Channels
1.2 W @ 24 VDC
 Power Consumption
Voltage: 2 MΩ
Current: 125 Ω
(Added by users)
mV, V or mA
±150 mV, ±500 mV, ±1
V, ±5 V, ±10 V and ±20
mA
100 dB
±25 ppm/° C
±6 µV/° C





Digital Input
 Channels
 Event Counter
Digital Input
 Channels
1
Logic levels 0: 1 V max.
1: 3.5~30 V
Pull up current: 0.5 mA, 10 kΩ resistor to +5 V
 Event Counter
Max. input freq: 50 Hz
ADAM-4013
1
logic level 0: +1 V max.
logic level 1: 3.5 ~ 30 V
pull up current: 0.5 mA,
10 kΩ resistor to +5 V
Max. input freq.: 50 Hz
Min. input pulse width:
1 msec.
Digital Output
 Channels
 Power Dissipation
Input Connections
2, 3 or 4 wire
Input Impedance
2 MΩ
Input Type
Pt or Ni RTD
NMR @ 50/60 Hz
100 dB
RTD Types and Temperature Ranges
IEC RTD 100 ohms
Pt
-100° C
to
+100° C a = 0.00385
Pt
0° C
to
+100° C a = 0.00385
Pt
0° C
to
+200° C a = 0.00385
Pt
0° C
to
+600° C a = 0.00385
JIS RTD 100 ohms
Pt
-100° C
to
+100° C a = 0.003916
Pt
0° C
to
+100° C a = 0.003916
Pt
0° C
to
+200° C a = 0.003916
Pt
0° C
to
+600° C a = 0.003916
Ni RTD
Ni
-80° C
to
+100° C
Ni
0° C
to
+100° C
 Sampling Rate
10 samples/sec.
 Span Drift
±25 ppm/° C
 Zero Drift
±3 µV/° C
2, open collector to 30
V, 30 mA max. load
300 mW
Common Specification
General
13-14
0.7 W @ 24 VDC
2, open collector to
30 V, 30 mA max. load
300 mW
 Power Dissipation






Analog Input
Dimensions (WxHxD)
Enclosure
Mounting
Power Input
Watchdog Time
Connectors
70 x 122 x 30 mm
ABS +PC
DIN 35 rail, stack, wall
Unregulated 10~30 VDC
1.6 sec. (system)
1 x Plug-in terminal
blcok (#14~22 AWG)
Remote DA&C Modules
Ordering Information
Environment
 ADAM-4011
 Humidity
5 ~ 95% RH
 Operating Temperature -10~70° C (14~158° F)
 Storage Temperature -25~85°C (-13~185°F)
 ADAM-4011D
 ADAM-4012
 ADAM-4013
Thermocouple Input
Module
Thermocouple Input
Module w/LED Display
Analog Input Module
RTD Input Module
ADAM 4000/4100 Series
Common Specifications
Unit: mm
Communication
 RS-485 (2-wire) to host
 Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080,
ADAM-4080D only support up to 38400 bps)
 Max. communication distance: 4000 feet (1.2 km)
 Power and communication LED indicator
 ASCII command/response protocol
 Communication error checking with checksum
 Asynchronous data format:
Advantech protocol: 1 start bit, 8 data bits, 1 stop bit, no parity
Modbus protocol: 1 start bit, 8 data bits, 1 or 2 stop bit, parity check (none, odd,
even) (ADAM-4100 series only)
 Up to 256 multidrop modules per serial port
 Online module insertion and removal
 Transient suppression on RS-485 communication lines
13-24
Dimensions
Remote DA&C Modules