ALLEN-BRADLEY 440L

Presence Sensing Safety Devices
Safety Light Curtain Interfaces
120V AC Power Supply and Safety Relay
Specifications
Input Power
120/230V AC
Power Consumption
2W/4W
Inputs
1 N.C. or 2 N.C. or
2 PNP (light curtain)
Maximum Input Resistance
110 ohms
Reset
Automatic/Manual
Outputs
3 N. O. Safety
1 N.C. Auxiliary nonsafety
Output Rating
N.O. B300, AC15, 5A/250V AC
N300, DC13, 3A/24V DC
Min. Switched Current/Voltage
10mA/10V
Description
Power ON Delay
1 second
The Allen-Bradley Guardmaster 120V AC interface box consists of a
NEMA 4 rated lockable metal enclosure, a DIN mount 3amp, 24V
DC power supply and either a single or dual 22.5mm safety relay(s).
Response Time
15ms
The single safety relay module provides 3 N.O. safety and one N.C.
auxiliary (nonsafety) “potential free” relay outputs. The dual safety
relay configuration allows for two pairs of safety light curtains to
independently control one or two machines.
The safety relay(s) can be configured for manual reset or automatic
reset. The resetting function can be through the key switch mounted
on the front cover of the interface box.
Pre punched holes located on the bottom of the enclosure allow for
easy wiring of the system.
Relay Module Indication LEDs
K1 Green = Power
Green = K1 Closed, if K1 alone is lit,
check for short across reset button
K2 Green = K2 Closed
Operating Temperature
-5°C to +55°C (+23° to +131°F)
Humidity
90% RH
Enclosure Protection
NEMA 4, IP65
Max. Conductor Size
1 x 2.5mm2 (14AWG) stranded
1 x 4mm2 (12AWG) solid
Weight
4886/5113g (10.75/11.25lbs)
Electrical Life
222V AC/4A/880VA 100,000 operations
cos 0 = 0.35
Maximum Operating Frequency
1200 cycles/hour
Mechanical Life
2,000,000 operations
Vibration
0.35mm 10-55Hz
Shock
10g, 16ms, 100 shocks
100ms
Recovery Time
2-54
Presence Sensing Safety Devices
Safety Light Curtain Interfaces
120V AC Power Supply and Safety Relay
Product Selection
Safety Outputs
3 N.O.
6 N.O.
Auxiliary Outputs
1 N.C.
2 N.C.
Power Supply
Catalogue Number
440L-M8400
440L-M8500
24V DC
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
200.0 (7.87)
161.9 (6.37)
301.6
(11.87)
3.17
(0.12)
1.77
(0.07)
63.5 (2.5)
22.2 (0.87)
104.7
(4.12)
2-55
Presence Sensing Safety Devices
Safety Light Curtain Interfaces
120V AC Power Supply and Safety Relay
Typical Wiring Diagram
M8400 Single Relay
L
Light Curtain
Interface Box
Fuse
Fuse
L1
K3
6
7 8 9
10 11 12 13 14 15 16 17 18
Fuse
4 5
Fuse
K4
1 2 3
Machine
Prime
Mover
Elements
Receiver
Transmitter
Relay Man. Restart
(Jump 15 & 16, 17 & 18)
Relay Auto Restart
(Jump 16 & 17)
PE
+24V
OSSD1
OSSD2
GND
TEST
PE
TEST
GND
+24V
K3 K4
K3 K4
K3
N
+24V
To red wire of
Safe/GuardShield
Receiver
2-56
Arc
Suppression
Devices
K4
Relay Auto Restart w/
MPCE Feedback
(N.C. contacts
between 16 & 17)
Man. Restart
Internal to
Light Curtain
(Jumper 16 & 17)
OR
(Jumper Req’d if mts
not used)
Relay Man. Restart w/
MPCE Feedback
(N.C. contacts between
15 & 16, Jumper 17 & 18)
L2
Presence Sensing Safety Devices
Safety Light Curtain Interfaces
120V AC Power Supply and Safety Relay
Typical Wiring Diagram
M8500 Dual Relay
L1
L
LC1
1 2 3
4 5
6
7 8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
LC2
Relay Man. Restart
Receiver
Transmitter
Receiver
Transmitter
LC1
(Jump 17 & 18, 19 & 20)
OSSD1
OSSD2
GND
+24V
PE
GND
+24V
PE
TEST
TEST
OSSD1
OSSD2
GND
+24V
PE
GND
+24V
PE
TEST
TEST
K4
(Jumper Req’d if mts
not used)
K5
K4
+24V
K4
To red wire of +24V
Safe/GuardShield
Receiver
LC1
K6
Relay Auto
Restart w/MPCE
Feedback
(N.C. contacts
between 21 & 22)
K3
(Jumper Req’d if mts
not used)
Arc
Suppression
Devices
100Ω, 2.2µF)
Relay Man.
Restart w/MPCE
Feedback
K5 K6
(N.C. contacts
between 18 & 19)
OR
(Jump 21 & 22)
(N.C. contacts between (N.C. contacts between
17 & 18, Jumper 19 & 20) 20 & 21, Jumper 22 & 23)
K3
OR
(Jump 20 & 21, 22 & 23)
Relay Auto Restart
(Jump 18 & 19)
K3
N
Fuse
K6
Fuse
K4
Light Curtain
Interface Box
Fuse
K5
Fuse
K3
LC2
Man. Restart
Internal to
To red wire of Light Curtain
Safe/GuardShield Relay Auto
Receiver
(Jumper 21 & 22)
LC2
K5
K6
2-57