Specifications (continued)
Safety Inputs
Sipha 1 1 N.C. & 1 N.O.
Sipha 2 & 6 6 x (1 N.C. & 1 N.O.)
Maximum Input Resistance
Terminals 1 – 4 200Ω
Terminals 2 – 3 150Ω
Minimum Approach Speed
17mm/s (0.67in/s)
Safety Outputs
Sipha 1 1 N.O.
Sipha 1 2 N.O.
Sipha 6 2 N.O. + 1 N.O. Delayed (0.6 to 30sec)
Output Rating
B300, AC-15, 4A/250V AC
P300, DC-15, 2A/30V DC
Minimum Switched Current/
Voltage
10mA/10V
With the increasing speed and complexity of applications a simple
magnetic switch may be insufficient to meet the increased risks,
therefore Sipha’s design incorporates several magnetically sensitive
elements which must be triggered in a particular sequence to operate
correctly. The Sipha sensor, designed to operate with its own
actuator, helps prevent defeatability by a simple magnet.
Maximum Recommended
Output Fuse
5A quick blow AC, 3A quick blow DC
The control unit is available in three types. The Sipha 1 control unit
operates on 24V AC/DC and offers 1 N.O. safety output and 1 N.C.
solid state auxiliary output. The Sipha 2 control unit operates on
either 24V AC/DC, 110V AC or 230V AC and offers 2 N.O. safety
outputs and 1 N.C. auxiliary output. The Sipha 6 has wiring
terminals for up to 6 sensors, a delayed output for Category 1 stops
and offers the same wide range of power supply capability as the
Sipha 2 control unit. Between 2 and 6 Sipha sensors can be directly
connected to the Sipha 6 control unit. An internal DIP switch mutes
the unused connections to sensors 1, 2, 3 and 4. This allows for
individual monitoring to each interlock and provides enhanced
safety integrity when compared to six interlocks running off a single
Sipha 2 control unit.
Auxiliary Output Switching
Capability
Sipha 1 100mA/230V AC, 100mA/24V DC
Sipha 2 & 6 2A/230 V AC, 2A/24 V DC
Description
Auxiliary Outputs (not for
safety use)
Sipha 1 1 N.C. Photovoltaic MOSFET (on
resistance typically 36Ω)
Sipha 2 & 6 1 N.C.
Indication LEDs
Green LED = Power on
Green LED = Output closed
Impulse Withstand Voltage
2500V
Installation Group
C in accordance with VDE 0110
Pollution Degree
3
Operating Temperature
-10°C to +55°C (+14° to +131°F)
Humidity
90% RH
Torque Settings—
Terminal Screws
1N⋅m (8.85lb⋅in)
The Sipha control units are designed to operate with the Sipha
sensors and actuators. The controllers have automatic reset.
Conductor Size
0.2-2.5mm2 (24-14AWG)
Case Material
Red Polycarbonate
Features
Mounting
35mm DIN Rail
•
•
•
•
Non contact actuation
Magnetic coded sensing
Control Unit acts as safety relay
Four types of switches
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119,
IEC60947-5-1, ANSI B11.19, AS4024.1
Category
Sipha 1 & 2 Cat. 3 per EN954-1
Sipha 6 Cat. 4 per EN954-1
Approvals
CE marked for all applicable directives,
cULus and TÜV
Power Supply
Sipha 1 24V AC/DC
Sipha 2 & 6 24V AC/DC and 110/230V AC
Power Consumption
Sipha 1 <2VA
Sipha 2 & 6 <4VA
3-56
Weight
Sipha 1 140g (0.31lbs)
Sipha 2 410g (0.90lbs)
Sipha 6 675g (1.49lbs)
Electrical Life
220V AC/4A880VA
cosϕ=.35
220V AC/1.7A375VA/
cosϕ=.6
30V DC/2A60W
10V DC/0.01A/0.1W
100,000 operations
500,000 operations
1,000,000 operations
2,000,000 operations
Mechanical Life
2,000,000 operations
Vibration
1mm, 10 to 55Hz
Shock
30g, 11ms half-sine
Interlock Switches
Non contact Switches
Sipha Control Units
Product Selection
Housing
Supply Voltage
Safety Contacts Auxiliary Contacts
Housing
Type
Catalogue
Number
24V AC/DC
1 N.O.
1 N.C. Solid State
22.5mm
Control Unit 1
440N-S32013
24V AC/DC
110V/230V AC
2 N.O.
1 N.C.
45mm
Control Unit 2
440N-S32021
24V AC/DC
110/230V AC
2 N.O.
1 N.O. Delayed
1 N.C.
90mm
Sipha 6
440N-S32052
Accessories
Housing
Page Number
Catalogue Number
14-6
440R-A31562
Replacement Fuse, 500mA
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
Sipha Control Unit Type 1
Sipha Control Unit Type 2
22.5 (0.89)
99 (3.9)
45.5 (1.79)
73 (2.87)
75 (2.95)
82 (3.23)
120 (4.72)
35mm DIN Rail Mounting
35mm DIN Rail Mounting
84 (3.31)
76 (2.99)
Sipha 6 Control Unit
83 (3.27)
118 (4.65)
90 (3.54)
3-57
Interlock Switches
Non contact Switches
Sipha Control Units
Block Diagrams
Sipha 1
A1
A2
13
X2
X1
Sipha 1
21
~
K1
Out
K1
K1
K2
Out
Pwr
~
K2
K2
K1
24V DC
110/230
K1
13 23 21
X1 X2
F2
F1
K2
Pwr
N +Ve
L
K1
K1
K2
3
4
L2
L3
K2
Logic
Logic
NC
1
-Ve
2
1
3
4
14
2
22
Typical Wiring Diagrams
24V AC/DC
L1
L2
L3
Yellow
Sipha
Sensor
Sipha
Actuator
Blue
2
1 A1 13 21 X1
K1
Sipha 1
Control
Unit
Guard
Closed
K2
Reset
22 X2
3 4 A2 14
Green
Red
K1 K2
Aux to Indicator
or PLC Input
M
Single Sipha Sensor, 24V Supply, Dual Channel
Output, Manual Reset, Monitored Output
110V AC
L1
L1
Sipha
Sensor
Sipha
Actuator
Blue
Yellow
2
Guard
Closed
1
110V
230V
3
4
A1
13
23
31 X1
Sipha 2
Control
Unit
A2
14
K1
Reset
24
K2
32 X2
Green
Red
K1 K2
Aux to Indicator
or PLC Input
N
Single Sipha Sensor, 110V AC Supply, Dual Channel
Output, Manual Reset, Monitored Output
3-58
M
14 24
22
Interlock Switches
Non contact Switches
Sipha Control Units
Typical Wiring Diagrams (continued)
24V AC/DC
L1
White
Black
2
Guard
Closed
L2
L3
Yellow
Sipha
Sensor
Sipha
Actuator
Blue
1 A1
13
23
31 X1
K1
Sipha 2
Control
Unit
Aux contact
for indication
Reset
3 4 A2
14
24
K2
32 X2
Guard
Closed
Green
Yellow
White
Red
Black
Sipha
Sensor
Sipha
Actuator
Blue
K1 K2
Aux to Indicator
or PLC Input
M
Aux contact
for indication
Guard
Closed
White
Red
Black
Sipha
Sensor
Sipha
Actuator
Blue
Aux contact
for indication
Multiple Sipha Sensor, Manual Reset,
Dual Channel Output, Monitored Output
Application Details
See page 3-62 for application details.
3-59