ALLEN-BRADLEY MSR122E

Safety Relays
Expansion Units
Minotaur MSR122E
Specifications
Standards
EN 954-1, ISO 13849-1, IEC/EN
60204-1, IEC 60947-5-1, ANSI
B11.19, AS4024.1
Category
Cat. 3 per EN 954-1 (ISO13849-1)
Approvals
C-Tick, CE marked for all
applicable directives, cULus and BG
Power Supply
24V AC/DC, 115V AC or 230V AC
0.8 to 1.1 x rated voltage, 50/60 Hz
(0.85 to 1.1 x 24V DC)
Power Consumption
3W
Safety Inputs
1 N.C. or 2 N.C.
Input Simultaneity
Infinite
Maximum Input Resistance
160 ohms
Description
Outputs
6 N.O. Safety
1 N.C. Auxiliary
1 N.C. Monitoring
The MSR122E is designed to be an expansion relay for use with the
Minotaur safety relays. The MSR122E is typically used in safety
system applications where additional outputs switching connections
are needed to help shut down a manufacturing process, properly and
safely.
Output Utilization per IEC
60947-4-1 (Resistive)
AC-1: 10A/250V AC
DC-1: 10A/24V DC
➊Output Utilization
per IEC 60947-5-1 N.O.
(Inductive) N.C.
The MSR122E can be connected as a single channel (1 N.C.) or dual
channel (2 N.C.) input configuration.
N.O.
N.C.
A300, AC-15
5A/250V AC, 5A/125V AC
2A/250V AC, 2A/125V AC
N300, DC-13
4A/24V DC
10A/24V DC @ 6 ops/min
The outputs include 6 normally open safety rated outputs used to
shut down the manufacturing system and 1 normally closed auxiliary
output to indicate the status of the MSR122E. One additional
normally closed output is available to allow the host relay to monitor
the status of the MSR122E. The safety, auxiliary and monitoring
outputs have independent and redundant internal contacts to help
ensure the safety function.
Features
•
•
•
•
Safety category according to wiring
6 Safety contacts
1 Auxiliary contact
1 Monitoring contact
current2 x number of contact paths/A2
Fuses Output (external)
6A Slow Blow or 10A Quick Blow
Min. Switched Current/Voltage
10mA/10V
Contact Material
AgSnO2 + 0.5µAu
Response Time
30ms
Indication LEDs
Green = CH1 Closed
Green = CH2 Closed
Impulse Withstand Voltage
2500V
Pollution Degree
2
-5°C to +50°C (+23°F to 122°F)
Enclosure Protection
IP40 (NEMA 1)
Terminal Protection
IP20
Conductor Size
0.2–4mm2 (24-12AWG)
ACV
Torque Settings—term. screws
0.4Nm (3.54 lb•in)
24V
Mounting
35mm DIN rail
Weight
550g (1.21lbs)
Electrical Life (w/Surge Supp.)
250V AC/10A/2500VA cosϕ=1
250V AC/5A/1250VA cosϕ=1
250V AC/5A/1250VA cosϕ=0.35
250V AC/5A/1250VA cosϕ=0.6
24V DC/2A/48W
10V DC/0.01A/0.1W
300,000 operations
700,000 operations
350,000 operations
500,000 operations
1,000,000 operations
2,000,000 operations
Mechanical Life
5,000,000 operations
200
150
100
50
Vibration
10-55 Hz, 0.35mm
Shock
10g, 16ms, 100 shocks
➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not
shown.
0
0
10
20
30
40
Ambient temperature/°C
4-58
See limit curve
Max 10A in one current path
Operating Temperature
Contact Current Limit Curve
250
Thermal Current (non switching)
50
60
Safety Relays
Expansion Units
Minotaur MSR122E
Product Selection
Inputs
Safety Outputs
Auxiliary Outputs
1 N.C. or 2 N.C.
6 N.O.
1 N.C.
Power Supply
Catalogue Number
24V AC/DC
440R-E21358
115V AC
440R-E21357
230V AC
440R-E21356
Dimensions—mm (inches) Block Diagram
109.5
(4.31)
A2 A3
13
23 33 43
53
63 81 X1
14
24 34 44
54
64 82 X2
MSR122E
87
(3.42)
A2 A4
100 (3.93)
75 (2.95)
4.5 (0.17)
Typical Wiring Diagrams
L1
+24V DC
Reset
Light Curtain
Out 1 Out 2
L1 L2 L3
L1 L2 L3
A1 A3 13 23 33 43 53 63 81 X1
A1 S11 S12 S21 S22 S52 S11 Y31 S33 S34 13 23 33 41 51
K1
MSR131RTP
MSR122E
K2
M
A2 X1 X2 X3 X4 Y30 Y32 Y35 Y2 Y1 14 24 34 42 52
24V DC Ground
N
K3
A2 A4 14
M
24 34 44 54 64 82 X2
K3
K1 K2
Output Inputs
Active Closed
120/230V AC Host (MSR131) with Dual Channel Light Curtain Input and
Single Channel Expansion (MSR122) with Monitoring
L1
Light Curtain
Out 2
Out 1
A1
S52 S11 S12
Reset
+
+24V DC
-
S21 S22
L1 L2 L3
S33 S34 13
23
37
47
L1 L2 L3
A1 A3 13 23 33 43 53 63 81
57
X1
K1
MSR138DP
A2
X1
X2
X3
X4
D1
MSR122E
K2
Y39 Y40
Y2
Timer Reset
Y1 14
24
K1
K2
38
48
58
M
A2 A4 14
D2
24 34 44 54 64 82
X2
M
D1 D2
Indicator
D1, D2 = Delayed Output Load
N
120/230V AC Host (MSR138) with Dual Channel Light Curtain Input and
Dual Channel Delayed Expansion (MSR122) with Monitoring
4-59