ALLEN-BRADLEY 889N-F7AG-30

Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Maximum scanning range
70m
Maximum beam gap
500mm
Minimum beam count
1 beam
Maximum beam count
4 beams
Minimum housing length
320mm
Maximum housing length
1800mm
Specifications
Description
Multi-beam safety light curtains from Rockwell Automation are
infrared protection devices with 1 to 4 infrared beams. They operate
on the through-beam principle, consisting of a sender and receiver
unit and are suitable for access control and perimeter guarding.
The PAC fulfils the pr EN 50100 requirements, safety category 4, in
that it is a self monitoring device.
• Integrated evaluation with state-of-the-art electronics and
especially developed ICs (ASICs)
• Beam coding for high interference immunity
• Actively monitored semiconductor outputs
• Mini style quick disconnect connectors
• Fast response time
• Large signal reserve (factor 2)
• Optical synchronization of sender and receiver units
• Multiple safeguarding by means of corner mirrors and columns
• Operating modes:
• Electronic Device Monitoring (EDM)
• Restart Interlock
• Muting configuration available
Standards
EN 50100
Approvals
BG and CE marked for all applicable
directives
Protected Height
Depends on product selection
Scanning Range
70m (225ft), single beam PAC 7.5m
Beam Gap
Depends on product selection
Enclosure Rating
IP 65
Connection Type
7-pin mini style on transmitter and 8-pin
on receiver
Supply Voltage Uv
Maximum Residual Ripple
24V DC ± 20%
5 Vss
Power Consumption
7 watts—Transmitter
6 watts—Receiver
Synchronization
Optical, without separate
synchronization channel
Outputs
Minimum output voltage
2 x PNP, 0.5 A, short circuit protected
Uv - 2V
Response Time
≤20ms
Protection
Short circuit and overload
Connection
Max. wire cross section
Cable length
The devices were designed for industrial applications and offer the
following advantages:
•
•
•
•
•
Beam coding for optimal interference immunity
Adaptability for safe PLC
Robust modular construction
Universal application possibilities
Simple installation
60m (196.8ft) maximum
Protection against over-voltage (≥1kV)
from Level 3 or higher (IEC 801 part 5;
2 kV)
between PE and +V.
Mode of Operation
Guard-only with manual restart
Safety Category
Type 4 (self-checking)
Requirement
According to EN 50100
Operating Ambient Temp.
0°C to 55°C (32°F to 131°F)
Air Humidity
15%...95% (not condensing)
Storage Temperature
-25°C to 70°C (-13°F to 158°F)
Approximate Dimensions
Height
Housing Cross Section
2-34
1.0mm2 with jacket
1.5mm2 without jacket
Length dependent upon protected
height; (see dimensional drawings)
52 mm x 55 mm (2.05in x 2.17in)
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Product Selection
1a. Multiple-Beam PAC
The Allen-Bradley Guardmaster PAC multiple beam safety light curtains are ordered as pairstransmitter and receiverand shipped under
one part number. After selecting the appropriate light curtain pair, ensure that required interfaces and accessories are ordered as well. The
single-beam PAC can be ordered with a passive mirror column (440L-AMIRSTDZ500) or two right angle mirrors (440L-AMIRR2).
Non muting Models
Size
mm
(inches)
Beam
Spacing
mm
Number of
Beams
684 (27)
500
600 (24)
Muting Models
Catalogue Number
Size
mm
(inches)
Beam
Spacing
mm
Number of
Beams
2
440L-P4H2500-N
684 (27)
500
2
440L-P4H2500M-N
220
3
440L-P4H3220-N
600 (24)
220
3
440L-P4H3220M-N
1000 (40)
400
3
440L-P4H3400-N
1000 (40)
400
3
440L-P4H3400M-N
534 (21)
120
4
440L-P4H4120-N
Catalogue Number
1b. Single-Beam PAC (Note: Maximum scanning range is 7.5 meters.)
Non muting Models
Size
mm
(inches)
Beam
Spacing
mm
Number of
Beams
684 (27)
500
1
Muting Models
Catalogue Number
440L-P4G1500-N
440L-AMIRSTDZ500
Required mirror unit
Size
mm
(inches)
Beam
Spacing
mm
Number of
Beams
684 (27)
500
1
Catalogue Number
440L-P4G1500M-N
440L-AMIRSTDZ500
Required mirror unit
2a. CordsetsRequired—PAC Transmitter
Female Connector
Face View of
Female
Connector Style
PAC Transmitter
6
5
1
7
4
2
Straight
3
Cable
Pin Wire Colour
1 Black
2 White
3 Blue
4 Brown
5 Grey
6 Yellow
7 Green
Wire Rating
(5)/18AWG
(2)20AWG
300V
3A
Length—m (ft)
Catalogue Number
2 (6.5)
889N-F7AG-2
5 (16.4)
889N-F7AG-5
10 (32.8)
889N-F7AG-10
15 (49.2)
889N-F7AG-15
20 (65.6)
889N-F7AG-20
30 (98.4)
889N-F7AG-30
Length—m (ft)
Catalogue Number
2 (6.5)
889N-F8AE-2
5 (16.4)
889N-F8AE-5
10 (32.8)
889N-F8AE-10
15 (49.2)
889N-F8AE-15
20 (65.6)
889N-F8AE-20
30 (98.4)
889N-F8AE-30
2b. CordsetsPAC Receiver and PAC Single Beam
Female Connector
Face View of
Female
Connector Style
PAC Single Beam and
PAC Receiver
6
7
5
2
8
4
Straight
1
3
Cable
Pin Wire Colour
1 Red
2 White
3 Blue
4 Brown
5 Grey
6 Yellow
7 Green
8 Pink
Wire Rating
18AWG
300V
3A
2-35
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Product Selection
3a. Safety Relay InterfacesRequired
Input
Voltage
24V DC
Floating
Blanking
Reset
Manual/
Automatic
no
Fixed
Blanking
no
PSDI
no
Muting
Outputs
no
4 amp
2 N.O.
Safety
1 N.C.
Aux.
More
Details
Catalogue Number
58
440L-M8200
3b. Safety Relay Interfaces—Optional
Relay
Input
Safety
Outputs
Auxiliary
Outputs
Terminals
Power
Supply
24V AC/DC
1NC,
2NC, or
Light Curtain
3 N.O.
1 N.C.
Removable
115V AC
230V AC
MSR127RP
Light Curtain or
Single Channel
(MSR126T)
Dual Channel
(MSR126.1T)
Light Curtain or
Single Channel
(MSR126R)
MSR126
2 N.O.
None
Fixed
Dual Channel
(MSR126.1R)
24V AC/DC
115V AC
230V AC
24V AC/DC
115V AC
230V AC
24V AC/DC
115V AC
230V AC
24V AC/DC
115V AC
230V AC
Reset
Catalogue
Number
Automatic/Manual
440R-N23132
Monitored Manual
440R-N23135
Automatic/Manual
440R-N23131
Monitored Manual
440R-N23134
Automatic/Manual
440R-N23130
Monitored Manual
440R-N23133
Automatic/Manual
Monitored Manual
440R-C23139
24V AC/DC
Light Curtain
or
Safety Mat
3 N.O.
2 N.C.
2 PNP Solid
State
Removable
115V AC
230V AC
MSR131RTP
2-36
440R-N23117
440R-N23116
440R-N23115
440R-N23114
440R-N23113
440R-N23112
440R-N23123
440R-N23122
440R-N23121
440R-N23120
440R-N23119
440R-N23118
Automatic/Manual
or
Monitored Manual
440R-C23137
440R-C23136
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Product Selection
4. Safety Relay InterfacesOptional (Used for muting applications)
Relay
Input
Voltage
Reset
Floating
Blanking
Fixed
Blanking
PSDI
Muting
Outputs
24V DC
Manual
no
no
yes
yes
2 N.O.
Safety
1 N.C. Aux.
More
Details
Catalogue Number
4-21
440R-P23071
MSR22LM
5. Power Supply
Description
Power supply:
Input93...265V AC
Output24V DC, 3 Amps
Catalogue Number
1794-PS3
6. AccessoriesOptional
Description
Catalogue Number
L-Mounting bracket, fixed (4 per package)
440L-AF6102
(1 package per system)
Mounting bracket, adjustable (4 per package)
440L-AF6103
(1 package per system)
Mounting bracket, adjustable with shock mount (4 per package)
440L-AF6104
(1 package per system)
Laser alignment aid
440L-ALAT
SafeShield adaptor for laser alignment aid
440L-ALBRK
Sliding nut kit (4 included)—Supplied with PAC
440L-AF6105
Muting lamp with 2m cable
440L-AMUTLP2M
Muting lamp with 10m cable
440L-AMUTLP10M
2-37
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Product Selection
7. Accessories—Mirrors and Mounting Columns
Corner Mirror
Specially constructed mirrors for 2 and 3 sided safeguarding applications. NOTE: Each mirror reduces maximum scan range by 10% per
mirror.
For PAC Models
Catalogue Number
2 Beam
500mm beam spacing
440L-A2MIRSTND
3 Beam
400mm beam spacing
440L-A3MIRSTND
440L-ASHIM
Mirror mounting shims
Mounting Columns
Description
Catalogue Number
Floor mounted column for 2 beam PAC
500mm beam spacing
440L-AMTSTND2B
Floor mounted column for 3 beam PAC
400mm beam spacing
440L-AMTSTND3B
Floor mounted column for 2 beam PAC column
with muting lamp
500mm beam spacing
440L-AMUTSTDLP2B
Floor mounted column for 3 beam PAC column
with muting lamp
400mm beam spacing
440L-AMUTSTDLP3B
Muting Sensors
Sensor
Transmitted Beam
Retroreflective
Polarized Retroreflective
Connection Location
Type
Catalogue Number
42GRL-9000-QD➋
Transmitter (powered from an external supply)
Receiver (connected directly to the muting module or 8100)
42GRR-9000-QD➊➋
Connected directly to muting module or 8100
42GRU-9000-QD➊➋
3 inch standard reflector
Dark Switching
Connected directly to muting module or 8100
3 inch standard reflector
92-39
42GRU-9200-QD➊➋
92-39
Connected directly to muting module or 8100
(Operating Lever must be selected separately.)
802M-NX10➊➋
➊ Use with 4-pin, 3-wire DC Micro patchcord when connecting to muting module (5m length shown). 1m, 2m, 3m, and 5m lengths
available, catalogue number 889D-F3ACDM-*. Where * = length in meters.
889D-F3ACDM-5
Mechanical Limit Switch
➋ Recommended cordset. when connecting to the 440L-M8100. Five meter length shown, other lengths available,
see page 15-10 of this catalogue.
2-38
889D-F4AC-5
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Approximate Dimensions—mm (inches)
Approximate Dimensions are not intended to be used for installation purposes.
Alternative Cable Connection PG 9
Cable Dia. 4 to 8 (0.16 to 0.31)
Multiple Beam
Single Beam PAC
PAC
440L-P4G2502-N
Mini
Connector
Mini
Connector
31 (1.22)
31 (1.22)
21 (0.83)
21 (0.83)
E
D
E
R3
R
C
A
R2
B
A
B
Detail A
Cross
Section
R1
F
F
23
(0.91)➊
23
(0.91)➊
27.5
(1.08)
Detail A
52
(2.05)
2.2
(0.09)
55 (2.17)
440L
T4H-2500-N
T4H-3220-N
T4H-3400-N
T4H-4120-N
A
500
440
800
360
B
684
597
985
534
C
524
437
825
374
D
80
80
80
80
E
107
107
107
107
F
77
50
78
67
R
500
220
400
120
PAC single beam
P4G 1500-N
500
684
524
80
97
87
500
14
(0.55)
6
(0.24)
6.7
(0.26)
3.5 (0.14)
10.5
(0.41)
➊ With respect to centre of housing
2-39
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Approximate Dimensions—mm (inches) (continued)
Approximate Dimensions are not intended to be used for installation purposes.
14
(0.55)
6
2.2 (0.09)
(0.24)
Detail A
69
55 (2.72)
(2.17)
3.5 (0.14)
52
(2.05)
21 (0.83)
81
(3.1)
6.7 (0.26)
52
(2.05)
10.5
(0.41)
23
(0.91)
55
(2.17)
27.5
(1.08)
F
500 668
(19.69) (26.3)
Detail A
A
B
C
87
(3.43)
G
B2
B1
E
A2
A1
179 (7.05)
440L-AMIRSTDZ500
Corner mirror—use with single-beam PAC
(440L-P4G1500-N or 440L-P4G1500M-N)
Muting Lamp
Connection
D
Mini
Connector
31 (1.22)
A
B
C
D
E
F
G
440L-R4H 2500M-N
500
663
524
80
265
77
86
440L-R4H 3220M-N
440
576
437
80
265
50
86
440L-R4H 3400M-N
800
964
825
80
265
78
86
440L-R4H 1500M-N
500
663
524
80
255
87
76
2-40
1
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Approximate Dimensions—mm (inches) (continued)
Approximate Dimensions are not intended to be used for installation purposes.
147.7
(5.81)
147.7
(5.81)
400
(15.75)
400
(15.75)
1216
(47.87)
1216
(47.87)
400
(15.75)
300
(11.81)
400
(15.75)
300
(11.81)
A
A
180
(7.09)
Bubble
Level
A-A
115
(4.53)
147.7
(5.81)
3.1
(0.12)
M10
15mm Dia.
Mounting the mirror columns—column 400
2-41
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Approximate Dimensions—mm (inches) (continued)
Approximate Dimensions are not intended to be used for installation purposes.
147.7
(5.81)
147.7
(5.81)
500
(19.69)
1216
(47.87)
500
(19.69)
1216
(47.87)
400
(15.75)
400
(15.75)
A
A
180
(7.09)
A-A
115
(4.53)
Bubble
Level
147.7
(5.81)
3.1
(0.12)
M10
15mm Dia.
Mounting the mirror columns—column 500
2-42
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Approximate Dimensions—mm (inches) (continued)
Approximate Dimensions are not intended to be used for installation purposes.
440L-AF6102
Slider nut
M5
M5 x 18
5.3
(0.21)
10
(0.39)
24
(0.94)
25
(0.98)
12
14
22
(0.87)
44
(1.73)
5
(0.2)
60
(2.36)
4.8
(0.19)
440L-AF6103
80 (3.15)
M5 x 18
65 (2.56)
40 (1.57)
23
(0.91)
30
(1.18)
2°
51
(2.01)
11
(0.43)
440L-AF6104
Adjustable mounting bracket
90 (3.54)
65 (2.56)
25 (0.98)
40 (1.57)
M5 x 20
23
(0.91)
30
(1.18)
11
(0.43)
51
(2.01)
2°
Attachment to machine
Adjustable bracket with shock mount 4 required
2-43
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Typical Wiring Diagrams
7-pin connector
6
5
1
7
2
Transmitter unit
Receiver unit and
single-beam PAC
Connection
Terminal
Connection
Terminal
8-pin connector
6
1
7
5
2
8
3
1 Red
2 White
3 Blue
4 Brown
5 Grey
6 Yellow
7 Green
8 Pink
1234567
Color
Black
White
Blue
Brown
Grey
Yellow
Green
1234567
+24V
0V
Test
Test
RW
RW
Pin
1
2
3
4
5
6
7
4
1234567
Pin
1
2
3
4
5
6
7
8
NC = No Connection
Transmitter
Receiver
Yellow
Amber
Yellow
Red
Amber
Green
LED indicator
Transmitter
Receiver
Yellow
sender range: high/low MCC test
Yellow
press restart switch
Amber
operating voltage is applied
Amber
contamination
2-44
3
1234567
+24V
0V
OSSD 1
OSSD 2
RES
EDM
OWS
4
Red
outputs inactive
Green
light beam unobstructed, outputs active
Color
Red
White
Blue
Brown
Grey
Yellow
Green
Pink
Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Typical Wiring Diagram
440L Light Curtain to 440R-N23135 (MSR127RP)
+24V DC
Test
3
Receiver
Sender
2
4
OSSDA
2
3
OSSDB
4
L1
L2
L3
K4
A
S52
K4
S12
13
23
33
41
14
24
34
42
MSR127RP
A2
S21
S22
S34
K5
K5
Reset
K4
K5
Bulletin 100S
Safety Contactors
or 700S Safety Relays
DC Common
Note: For the 440L PAC unit, set the dip switches as follows:
SW 1, 5, 6, 7, 8 to “B”
SW 2, 3, 4 to “A”
The dip switches are accessed by removing the connection cap of the receiver unit. The sender unit will not need dip switch configuration if these
receiver settings are used.
2-45