ARTESYN PM301CE

PM300CE SERIES
Single, dual and triple output
•
•
•
•
•
•
•
•
•
[ 2 YEAR WARRANTY ]
SPECIFICATION
Encapsulated package
2.5 to 15W modules
230VAC input (115VAC version, see PM300 series)
Chassis mounting inserts
Terminal strip connections
Short circuit protection
EN55022, EN55011 conducted emissions level B
EN61000-4-2, -3, -4, -5, -6 compliant
Meets EN60950
The PM300CE series is an encapsulated, chassis mountable linear AC/DC power
module with the CE mark to demonstrate compliance with the Low Voltage Directive
for European applications. The series has single, dual and triple output models with
industry standard output configurations operating from an input voltage of 230VAC
making the PM300CE series suitable for a wide range of low power chassis
applications. The PM300CE series includes 2.5W to 15W modules. Each module has
short-circuit protection and the 5V outputs also have overvoltage protection.
Conservative design and rating of these modules results in reliable operation and long
life. There are four threaded inserts in the bottom of each module for convenient
chassis mounting. The PM300CE design is a low emissions design with tightly
regulated outputs making the series especially suitable for test, measurement and
instrumentation equipment.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
OUTPUT SPECIFICATIONS
Voltage accuracy
±1.0%, max.
Line regulation
See table on
facing page
Load regulation
See table on
facing page
Temperature coefficient
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022
EN55022
EN61000-4-2,
EN61000-4-2,
EN61000-4-5,
EN61000-4-4,
EN61000-4-3,
EN61000-4-6,
level
level
level
level
level
level
3
4
3
3
3
3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
Level B
Level B
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
±0.02%/°C
GENERAL SPECIFICATIONS
Overvoltage protection
(See Note 4)
5V outputs only
6.2V typical
Efficiency
Output power limit
130% to 200% FL typ.
Short circuit protection
100% to 200% FL
Input frequency range
Safety ground leakage
current
Isolation voltage
3000VAC
Isolation capacitance
50pF
Approvals and
standards (See Note 5)
INPUT SPECIFICATIONS
Input voltage range
40% typical
Meets EN60950
230VAC ±10%
(See Note 2)
Case material
UL94V-0
Non-conductive
black plastic
Weight
Case C1
Case C2
567g (20.02oz)
816g (28.80oz)
47Hz to 400Hz
<3.5mA @ 50Hz
MTBF (See Note 3)
710,000 hours
ENVIRONMENTAL SPECIFICATIONS
PAGE 1
Temperature
Operating ambient
–25°C to +71°C
Non-operating amb. –25°C to +71°C
Derating, 50°C to 71°C
2.5%/°C
Cooling
Free-air convection
cooled
Relative Humidity
Non-condensing
20% to 95% RH
ENCAPSULATED LINEAR AC/DC POWER SUPPLIES
|
2.5-15W AC
2.5 to 15 Watt
AC/DC encapsulated modules
OUTPUT
VOLTAGE
OUTPUT
CURRENT
OVP
REGULATION
LINE
LOAD
(4)
RIPPLE AND
NOISE
CASE
AVAILABLE MODELS
SINGLE OUTPUT
5VDC
500mA
Yes
±.05%
±0.10%
2mV rms
C1
PM334CE
5VDC
1000mA
Yes
±.05%
±0.15%
2mV rms
C1
PM342CE
5VDC
2000mA
Yes
±.05%
±0.15%
2mV rms
C2
PM345CE
DUAL OUTPUT
±12VDC
±240mA
No
±0.05%
±0.05%
1mV rms
C1
PM337CE
±12VDC
±400mA
No
±0.05%
±0.05%
1mV rms
C2
PM397CE
±15VDC
±100mA
No
±0.05%
±0.05%
1mV rms
C1
PM302CE
±15VDC
±200mA
No
±0.05%
±0.05%
1mV rms
C1
PM365CE
±15VDC
±350mA
No
±0.05%
±0.05%
1mV rms
C2
PM301CE
±15VDC
±500mA
No
±0.05%
±0.05%
1mV rms
C2
PM396CE
TRIPLE OUTPUT
(1)
5V/±12VDC
500/±120mA
Yes
±0.05%
±0.1%/±0.05%
1mV rms
C1
PM391CE
5V/±15VDC
500/±100mA
Yes
±0.05%
±0.1%/±0.05%
1mV rms
C1
PM390CE
5V/±15VDC
1000/±150mA
Yes
±0.20%
±0.1%/±0.02%
1.0/0.5mV rms
C2
PM393CE
5V/±12VDC
1000/±150mA
Yes
±0.20%
±0.1%/±0.02%
1.0/0.5mV rms
C2
PM392CE
Note
1
2
3
4
5
Triple output models only: the 5V output common is isolated from the
±12VDC or ±15VDC common.
Some units should be derated for operation at 400Hz. Please contact the
factory for details.
M.T.B.F. figures are based on actual product performance. Consult factory
for details.
Triple output models only: overvoltage protection is only available on the
5V outputs.
All models are only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
CASE C
0.75
(19.1)
INSERTS
4.40 THREAD
0.125 (3.2) DEEP
2.50
(63.5)
Single
Output
Models
0.75
(19.1)
Dual
Output
Models
Triple
Output
Models
5.40 BH
Screws
4.00
(101.6)
AC
AC
AC
AC
AC
AC
– 5V OUT
NC
NC
NC
– OUT
+ 5V OUT
– 12V OUT
– 15V OUT
COM
COM
+ OUT
+ OUT
COM
+ 12V OUT
+ 15V OUT
C1 C2
2.00
(50.8)
2.70
(68.6)
0.35
(8.9)
1.45
(36.8)
2.00
(50.8)
ALL DIMENSIONS IN INCHES (mm)
http://www.artesyn.com
PAGE 2
DS_PM300CE_19980401.PDF
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising