ARTESYN BXA30-24T05-15

BXA30 Series
Triple output
DC/DC CONVERTERS
30W Wide Input DC/DC Converters
1
• Pin-compatible with BXA15 series
• Designed to meet telecom power supply interface
standard ETS300-132-2
• UL, CSA and VDE approvals
• VDE0878 and EN55022 conducted emissions level A
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• Fixed frequency operation at 350kHz
• MTBF in excess of 7,005,000 hours (demonstrated)
• Basic insulation system
The BXA30 triple output Series, comprising 2 different models, has been conceived as an
applications-specific range of DC/DC converters, specifically addressing telecommunications,
industrial electronics, test equipment, mobile telecommunications and distributed power
applications. The series offers two wide input voltage ranges, 18-36VDC and 36-75VDC.
Designed to meet ETSI telecoms interface standards ETS300-132-2 and BTR2511, together
with internal filtering to EN55022 level A, safety approval to EN60950 and UL1950, and basic
insulation of 1500VDC, the 48VDC model is ideal for telecommunications applications.
The 24V model is particularly suited to industrial, mobile telecom and test equipment
applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity compliant. Other features
include low output ripple, overvoltage protection, short circuit protection, remote enable.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Output power
30W
Line regulation
(See Note 1)
Main output
Auxiliary output
±0.5%
±2.0%
Load regulation
(See Note 2)
Main output
Auxiliary output
±1.0%
±3.0%
Ripple and noise
(20MHz bandwidth)
Main output
Auxiliary outputs
Temperature coefficient
75mV pk-pk
15mV rms
100mV pk-pk
20mV rms
±0.02%/°C
Overvoltage protection
Transient, all outputs
Short circuit protection
All outputs
(See BXA15/30 Design Note 101)
Transient response
25% to 100% load, all outputs
Voltage accuracy
Main output
Auxiliary output
Load cross regulation
20% to 100% load
Main: output
1.0%
Auxiliary: output
10%
50% to 100% load, main, >20% aux.
Main output
1.0%
Auxiliary output
4.0%
Minimum load
(See Note 10)
Main output for auxiliary
regulation
135% Vout init.
Yes
10%
±1.5%
±3.0%
>10%
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15 (Note 3) Level A
EN55022, FCC part 15 (Note 4) Level B
VDE0878 (Note 3) (48V)
Level A
EN55022, FCC part 15
Level A
EN61000-4-2, level 3
Perf. criteria 2
EN61000-4-2, level 4
Perf. criteria 2
EN61000-4-5, level 3
Perf. criteria 2
EN61000-4-4, level 3
Perf. criteria 2
EN61000-4-3, level 3
Perf. criteria 2
EN61000-4-6, level 3
Perf. criteria 2
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Basic insulation
Input/output
Input/case, 48V models
Switching frequency
Fixed
1500VDC
1500VDC
350kHz, nom.
Approvals and
standards
(See Note 11)
VDE0805, EN60950
EN41003, IEC950, UL1950
CSA C22.2 No. 950
Case material
Aluminum substrate
with plastic case
Material flammability
UL94V-0
Weight
MTBF (See Note 9)
INPUT SPECIFICATIONS
130g (4.6oz)
Demonstrated @ 25°C
7,005,000 hours
ENVIRONMENTAL SPECIFICATIONS
Input voltage range
24Vin nominal
48Vin nominal
Reverse voltage prot.
(See Note 6)
Max. input rise and
fall time
48V
Remote ON/OFF
Logic compatibility
ON
OFF
Conducted emissions
18 to 36VDC
36 to 75VDC
Thermal performance
Yes
5V/ms
ETS300-132
CMOS/TTL
Open circuit
<1VDC
Thermal impedance
Baseplate operating
temperature,
(See Notes 5, 7)
Non-operating
-25°C to +100°C
-55°C to +100°C
Free air convection,
baseplate to air
With heatsink (See Note 7)
6.5°C/W
5.2°C/W
File Name: BXA30T.PDF Rev: 02 Oct 2002
BXA30 Series
Triple output
DC/DC CONVERTERS
30W Wide Input DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT (MAX.)
OUTPUT
INPUT CURRENT
CURRENT (MIN.)
NO LOAD
18-36VDC
5/±15VDC
3/±0.5A
0.3/±0.05A
36-75VDC
5/±12VDC
3/±0.625A
0.3/±0.062A
TYPICAL
EFFICIENCY
MODEL
NUMBER (3,5)
70mA rms
81%
BXA30-24T05-15
40mA rms
83%
BXA30-48T05-12
Notes
PIN CONNECTIONS
1
2
3
Nominal line to high line. Nominal line to low line.
20%FL to full load. The value stated is for balanced loads.
An optional internal filter is available, which will meet VDE0871 level A,
VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model
number, e.g. BXA30-48T05-12-F. See BXA15 and BXA30 Design Note 100.
4 For conducted noise operation of the BXA30 to VDE0871, VDE0878 and
EN55022 level B, see BXA15 and BXA30 Design Note 100.
5 For extended operating temperature, include the heatsink option, ‘-1’
in the model number. Maximum heatsink height is 12.5mm, e.g.
BXA30-48T05-12-1.
6 Reverse voltage protection can be implemented by putting a slow blow
fuse on the negative input rail. Rate the fuse for 100VDC at 1.5A for the
48V model and 50VDC at 3A for the 24V model.
7 The maximum operating ambient temperature, without derating depends on
internal power dissipation and cooling method. BXA15 and BXA30 Design
Note 100 provides detailed thermal calculations and design-in details.
8 Visit the Artesyn website to download a copy of Design Note 100.
9 Test results to-date are 1,590,000 hours @ 46˚C. The MTBF figure shown
includes a calculated acceleration factor of 4.1 based on an activation
energy of -0.55 eV.
10 The load on the main output must exceed 10% to ensure operation of the
unit to specification.
11 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
PIN NUMBER
TRIPLE OUTPUT
1
+ Vin
2
– Vin
3
+ Auxiliary Output
4
Output Common
5
– Auxiliary Output
6
+ Main Output
7
No Connection
8
Remote On/Off
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 14501-3336-7006
Licence No. 6231
UL1950 File No. E174104
CSA C22.2 No. 950 File No. LR41062C
2.50
(63.5)
0.20 (5.08)
0.80 (20.32)
0.50 (12.70)
0.76
(19.20±0.30)
3.02
(76.30 ± 0.30)
0.302
(7.67±0.30)
0.20
(5.08)
3
8
4
5
0.6 (15.24)
0.95
(24.13)
1
6
0.70 (17.78)
0.30 (7.62)
BOTTOM
VIEW
2.41
(61.10±0.30)
0.4 (10.16)
2
1.30
(33.02)
7
1.15
(29.21)
Ø 1.000
8 Places
Case/Metal Inserts M3.0
(Typ. 4 Places)
2.00
(50.80)
ALL DIMENSIONS IN INCHES (mm)
0.52
(13.30±0.30)
SIDE VIEW
Tolerance .XX ±0.02
.XXX ±0.005
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Design Note
www.artesyn.com
File Name: BXA30T.PDF Rev: 02 Oct 2002