2003 USB1.1 Interface Support 3912-20 COMMUNICATION BASE Complete with LCD for Checking Data and Making Settings in the Field USB Interface for Connecting the Data Logger Series to a PC 3632-20 TEMPERATURE LOGGER Waterproof with built-in sensor -20.0˚C to 70.0˚C 3638-20 LEAK LOGGER For measuring leak current on two channels 100.0 mA/1000 mA AC (clamp sensor sold separately) 3633-20 TEMPERATURE LOGGER Separate external sensor -40.0˚C to 180.0˚C 3639-20 PULSE LOGGER For cumulative pulse measurement for a precipitation gauges, flow gauge, etc. 3634-20 INSTRUMENTATION LOGGER For measuring typical instrumentation signals DC 20.00 mA 3640-20 LUX LOGGER For illumination measurement 2000 lx to 200000 lx 3635-24/-25/-26 VOLTAGE LOGGER -24: DC ± 500.0 mV -25: DC ± 5.000 V -26: DC ± 50.00 V 3641-20 HUMIDITY LOGGER Alternates recording of temperature and humidity on two channels -40˚C to 85.0˚C 0.0%rh to 100.0%rh 3636-20 CLAMP LOGGER For measuring alternating current on two channels 50.00/500.0 A AC (clamp sensor sold separately) 3645-20 VOLTAGE LOGGER With preheat function DC ± 50.00 mV to ± 50.00 V 3637-20 AC VOLTAGE LOGGER AC 600.0 V 3912-20 ■ Compatible with the USB 1.1 interface ■ Equipped with an LCD display that makes it easy to check collected data and change settings in the field ■ Improved reliability in data retention ■ Does not consume battery power while connected to a PC http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available on our website. ■ Clock backup when battery needs replacement (approximately 12 hours) ■ Same easy-to-use interface, like the current 3911-20 ■ Integrates with PC software for the 3911-20 (Operates with both the 3911-20 and the 3912-20) Select Either USB or the RS-232C as the PC Communication Interface for the Data Logger Series The USB-compatible 3912-20 has been added as a communication base for the flexible Data Logger Series of compact loggers for measuring information such as temperature, humidity, instrument signals, load current, leak current, voltage, pulse signals, and illumination. There are now two types of communication bases (which are used to download data recorded by a Data Logger to a PC) for the Data Function Specifications Specifications of Bundled PC Communication Software Display Dot matrix LCD (128 × 64 dots) Communication combinations PC → 3912-20 Communication method 3912-20 ⇔ Logger Infrared optical communications (synchronous serial communications, three lines) Clock, recording interval, start control, recording method, comment 3912-20 → PC Collected data (16 channels maximum: 256,000 data elements maximum) 3912-20 → Logger Clock, recording interval, start control, recording method, comment Logger → 3912-20 Collected data (16,000 data elements maximum) 3912-20 ⇔ PC Logger Series: the RS-232C-compatible 3911-20 and the newly released USB 1.1-compatible 391220. The communication bases have proven popular for their ability to facilitate the collection of data in the field. Because the 3912-20 is equipped with an LCD, it also allows the user to easily check data and change settings. USB 1.1 (full speed: 12 Mbps) Communication speed 3912-20 ⇔ Logger Approximately 250 data elements/second (reference value) 3912-20 ⇔ PC Approximately 16,000 data elements/second (reference value) Cable USB cable (provided, approximately 1m) Recording capacity 16 channels maximum (16,000 data elements maximum × 16 channels) ● Supported OS: Windows 98/Me/2000/XP (for DOS/V) ● Display: Graph display (16 channels maximum, two cursors, enlarge/reduce/scroll possible), measurement data list display, data count, average value, maximum value, minimum value, recording date and time ● Printing: Graph printing (16 channels maximum, printing between cursors), measurement data list, data count, average value, maximum value, minimum value, recording date and time ● File formats: Proprietary format (binary code), text save (CSV format) * CSV format: A comma-delimited text format that can be directly read by Excel ● Analysis and data processing data on computer General Specifications ● Backup: Yes (Prevents loss of stored data during battery replacement; clock is backed up by a two-layer capacitor for approximately 12 hours) (reference value) ● Battery life: Approximately 3 months or more (when idle) ● Communication: Approximately 50 times (sending 16,000 data elements × 16 channels from Data Logger → 3912-20 → PC) ● Power supply: 1.5V batteries × 4 alkaline dry cells (LR03) ● Maximum rated power: 0.4 VA ● Dimensions: Approx. W68.5 mm (2.70 ") × H128 mm (5.04 ") × D36 mm (1.42 ") (expluding protrusions) ● Mass: 180g(6.35 oz.) (including batteries) ● Locations for use: Indoors, at altitudes of up to 2000 m (6562 -ft.) ● Operating temperature range: 0˚C(32˚F) to 40˚C(104˚F), up to 80%rh (with no condensation) ● Storage temperature range: -10˚C(14˚F) to 50˚C(122˚F), up to 80%rh (with no condensation) ● Applicable standards: EMC EN61326-1:1997+A1:1998 Safety EN61010-1:2001 overvoltage category I (expected overvoltage of 30 V), pollution degree 2 ● Accessories: Operation Guide, USB cable, PC communication software (CD-R), alkaline batteries (LR03) × 4 ● Communication between the 3912-20 and a Data Logger Data Logger Use either the 3912-20 COMMUNICATION BASE (USB) or the 3911 -20 COMMUNICATION BASE (RS-232C) for communication (transferring data and settings) between a Data Logger and a PC. The 3912-20 can collect up to 16,000 data elements for up to 16 channels; when installed in the field, the 391220 can collect data from multiple devices and then send all of the data to a PC for analysis and processing. ● Communication between the 3912-20 and a PC 3912-20 3912-20 PC communication software USB cable Install in a fixed location when using infrared optical communication DISTRIBUTED BY ASM GmbH Am Bleichbach 18 - 22 HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp 85452 Moosinning HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@ hiokiusa.com All information correct as of Feb. 20, 2003. All specifications are subject to change without notice. I3912E1-32M-03P Printed in Japan