2000 3636-20 CLAMP LOGGER 3637-20 AC VOLTAGE LOGGER Environmental Measuring Instrument Easy clamp current recording and convenient, low-cost voltage recording Extended recording of AC current and voltage transients ● D a t a b a c k u p w h e n b a t t e r i e s a re e x h a u s t e d o r re p l a c e d ● I n s t a n t a n e o u s / a v e r a g e re c o rd i n g ( a v e r a g e o v e r re c o rd i n g i n t e r v a l ) ● G r a p h i c d i s p l a y o f re c o rd e d d a t a t h ro u g h a c o m p u t e r ● Equipped with alarm output (3636-20) http://www.hioki.co.jp/ ISO14001 JQA-E-90091 HIOKI company overview, new products, environmental considerations and other information are available on our website. 3636-20 CLAMP LOGGER 500A AC 3637-20 AC VOLTAGE LOGGER 600V AC Analyze and Process Data on a Personal Computer The 3911-20 Communication Base is used to transfer data to a personal computer. The 3911-20 accommodates up to 16,000 points of 16-channel data or 32,000 points of 8-channel data. It captures data from multiple loggers, then transfers data to the computer where it can be analyzed and managed. 3911-20 LOGGER Functions Infrared optical communication Approximately 500 data points/second RS-232C Approximately 1000 data points/second (Logger and 3911 must be in direct contact for communication.) Communication software included with the 3911-20 Settings for communication software Current time, recording interval, recording start, recording method, comment, recording mode (3636-20/3637-20). Alarm and channel selection (3636-20 only) Compatible OS: Windows 95/98/NT4.0 ● Graph display ● Measurement data tabulation ● Printing (data, graphs) ● Scaling ● File saving (in proprietary format or text format) Windows is a registered trademark of Microsoft Corporation ■ 3636-20/3637-20 Specifications ■ 3636-20/3637-20 Common Specifications Display * 50A or 500A range when using the 9650, and 500A range when using the 9651 : Measured value, recording status, recording interval, battery condition, unit, recording in progress, preset active, average value recording, maximum value, minimum value, alarm (3636-20 only) : Started manually or at preset time Recording start : Manual stop or until memory is full Recording finish : 1/2/5/10/15/20/30 seconds, 1/2/5/10/15/20/30/60 minutes Recording interval : One-time: Recording stops when memory becomes full. Recording methods Endless: Oldest data is overwritten when memory becomes full. : Instantaneous value recording, average value recording Recording modes (average over the recording interval) : Infrared optical communication (requires the 3911) Interface : LR03 (AAA) × 4 alkaline batteries Power supply : 0.1 VA Maximum rated power : About 1 year (with a recording interval of 1 minute and Continuous use time instantaneous value recording) About 1 month (with average value recording) : Approx. 57.5(W) × 86.5(H) × 30.0(D) mm, approx. 130 g Dimensions/mass : Indoors at an altitude of no more than 2000 m Operating environment : 0 to 50˚C, less than 80% rh (no condensation) Ambient use conditions Ambient storage conditions : -10 to 60˚C, less than 80% rh (no condensation) : EMC EN61326-1 : 1997+A1 : 1998 Applicable standards Safety EN61010-1 : 1993+A2 : 1995 Overvoltage category I (anticipated overvoltage: 330V), pollution index 2 (3636-20) Overvoltage category III (anticipated overvoltage: 6000V), pollution index 2 (3637-20) ■ 9650/9651 Specifications ■ 3911-20 COMMUNICATION BASE Specifications 3636-20 CLAMP LOGGER 3637-20 AC VOLTAGE LOGGER Input AC current AC voltage Number of input channels 2 channels 1 channel Data recording capacity 32,000 data points (1 ch) 16,000 data points (2 ch) 32,000 data points Measurement range 0.00 to 500.0 Arms.sin (50A/500A, 2 ranges) 0.0 to 600.0 Vrms.sin ±1% rdg. ±5 dgt. (logger only) ±2.5% rdg. ±8 dgt. (logger + sensor)* ±1% rdg. ±5 dgt. Accuracy (50/60 Hz, 23±5˚C) Alarm output ON when set upper/lower limits exceeded None Measurement system True RMS calculation True RMS calculation LR03 (AAA) alkaline batteries × 4, 9632 connection cord (for alarm output) LR03 (AAA) alkaline batteries ×4, 9639 connection cord (for input) 3911-20 Communication Base, 9650/9651 Clamp-on Sensor 3911-20 Communication Base Accessories Options × Rated primary current Rated secondary current 9650 CLAMP ON SENSOR 9651 CLAMP ON SENSOR AC100A AC500A AC100mA AC500mA ±1.5% rdg. ±0.03%f.s. (where f.s. is rated primary current) ±1.5% rdg. ±0.03%f.s. (where f.s. is rated primary current) Frequency response 40 Hz to 1 kHz, within ±8% 40 Hz to 1 kHz, within ±3% Maximum rated input 130A continuous (45 to 66 Hz) 600A continuous (45 to 66 Hz) AC 300Vrms or less (insulated conductor) AC 600Vrms or less (insulated conductor) φ 15 mm or less φ 46 mm or less Approx. 3 m Approx. 3 m Accuracy (50/60 Hz, 23±5˚C) Circuit voltage Measurable conductor diameter Cord length Dimensions/ mass Approx. 46(W) × 135(H) × 21(D) mm, Approx. 77(W) × 151(H) × 42(D) mm, approx. 200 g approx. 340 g : Max 16,000 data points × 16 ch / 32,000 data points × 8 ch : Logger ⇔ 3911-20: by infrared optical communication (with units in close contact) 3911-20 ¤ PC: by RS-232C connection : LR03 (AAA) × 4 alkaline batteries Power supply : 0.2 VA Maximum rated power : Approx. 69(W) × 92(H) × 36(D) mm, approx. 150 g Dimensions/mass : 0 to 40.0˚C, max 80% rh (no condensation) Ambient use conditions Ambient storage conditions : -10.0 to 50.0˚C, max 80% rh (no condensation) : PC communication software Accessories Recording capacity Communication type 9650 9651 9639 9632 CLAMP ON SENSOR CLAMP ON SENSOR CONNECTION CABLE CONNECTION CABLE ■ Options 3636-20 CLAMP LOGGER 3637-20 AC VOLTAGE LOGGER The 3636-20 CLAMP LOGGER cannot be used for measurement by itself. A clamp-on sensor (sold separately) is required. 3911-20 COMMUNICATION BASE 9650 CLAMP ON SENSOR (100A) 9651 CLAMP ON SENSOR (500A) 9632 CONNECTION CABLE (included with the 3636-20, 1 m) 9639 CONNECTION CABLE (included with the 3637-20, 3 m) 9637 RS-232C CABLE (9 pin-to-9 pin, null modem, 1.8 m) 9638 RS-232C CABLE (9 pin-to-25 pin, null modem, 1.8 m) DISTRIBUTED BY HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL+81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp ASM GmbH Am Bleichbach 18 - 22 85452 Moosinning All information correct as of Apr. 7, 2000. All specifications are subject to change without notice. ■Inter net HIOKI website h t t p : / / w w w . h i o k i . c o . j p / F3636E1-04B-05P Printed in Japan 2001 3638-20 LEAK LOGGER DATA LOGGER Simple Leak Current Recording with Clamp On Sensors. Easy Logging at Low Cost Recording and Monitoring Leak Current ●Select from three types of clamp on leak current sensors ●Compact, light weight (130g), two-channel recording ●High-capacity recording (32,000 data points) Recording interval: 15 steps from 1 second to 60 minutes ●Accurate true effective value calculation even for distorted waveforms (100/1000 mA) ●Maximum or average value recording (max./ave. within recording interval) ●View recording data graphically on a PC ●Data is protected during battery discharge and replacement Model 9657 Model 9658 Model ISO14001 JQA-E-90091 9659 http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available on our website. ■ HIOKI 3638-20 LEAK LOGGER Specifications Data Analysis and Processing on a PC Sensor models HIOKI 9657, 9658 and 9659 CLAMP ON LEAK SENSORS Inputs & ranges 2 channels, 100.0 and 1000 mA (manual range selection) Instrument accuracy ±1% rdg. ±5 dgt. at 50/60 Hz, 23 ±5˚C, with built-in filter for 50/60Hz Data can be transferred to a PC using the HIOKI 3911-20 COMMUNICATION BASE. Up to 16,000 data points can be collected from 16 channels, (or up to 32,000 data points can be collected from 8 channels), and then transferred to the PC for analysis and processing. with 9657 or 9659 sensor ±2% rdg. ±10 dgt. (100 mA range) ±2% rdg. ±6 dgt. (1000 mA range) ±4.5% rdg. ±10 dgt. (100 mA range) ±4.5% rdg. ±6 dgt. (1000 mA range) Combined accuracy at 50/60 Hz, 23 ±5˚C with 9658 sensor Measurement period 1 or 0.2 s (one channel only) Recording modes Maximum or average value Recording interval 1, 2, 5, 10, 15, 20 or 30 s, and 1, 2, 5, 10, 15, 20, 30 or 60 min. Recording data quantity 32,000 data points (single channel), 16,000 data points (for dual-channel recording) Recording start / end Manual, or at preset time / Manual, or when memory full Recording methods Single recording, Endless recording Max./Min. display Maximum and Minimum values are displayed Alarm output On when input crosses preset upper and lower limits (open-collector output) Backup Data backup is provided Interface Serial infrared transfer 3911-20 3911-20 3638-20 (Infrared transfer) RS-232C Cable Settings that can be made from communications software: Power supply, AAA-size alkaline batteries (LR03 × 4), 0.1 VA consumption Continuous operating One month (with power saver on, 1s measurement period) Ten days (with power saver off, 0.2s measurement period) period Approx. 57.5(W) × 86.5(H) × 30.0(D) mm (less projections), approx. 130g Size & weight (including batteries) current time, recording interval, recording start, recording methods, comment, recording mode, alarm, channel selection ■ HIOKI 3911-20 COMMUNICATION BASE Specification Communication method Up to 16,000 data points × 16 channels, Up to 32,000 data points × 8 channels Infrared between Leak Logger and 3911-20, RS-232C serial between 3911-20 and PC Recording capacity Power supply Four AAA size alkaline batteries (LR03 × 4) Operating temperature & humidity 0 to 50˚C, 80% RH or less (noncondensing) Size & weight Approx. 69(W) × 92(H) × 36(D) mm, approx. 150 g Supplied accessories AAA-size alkaline batteries (LR03 × 4), Model 9632 CONNECTION CABLE (for alarm output) Supplied accessories PC communications software Supported operating systems Windows 9x, NT 4.0 ■ Clamp On Current Leak Sensor Specifications 9657 9658 9659 Up to 40 mm dia. Up to 12 × 30 mm Up to 30 × 150 mm 60A Continuous at 45 to 65 Hz 10A Continuous at 45 to 65 Hz Model Measurable conductor size 1.0A AC Rated primary current Maximum allowable input Amplitude accuracy Residual current ±1.0% rdg. ±12 µV ±3.5% rdg. ±12 µV ±1.0% rdg. ±12 µV 5 mA (at 100A AC in) 1 mA (at 10A AC in) 30 mA (at 500A AC in) 5 mA equiv. With 400A/m (AC), 7.5 mA max. External magnetic field effect Approx. 3 m Cable length Voltage to ground Insulation withstand voltage 300 Vrms AC 150 Vrms AC 460 Vrms AC 3.7 kV (for 1 min.) 2.3 kV (for 1 min.) 2.2 kV (for 1 min.) 0 to 50˚C, 80% RH or less (non-condensating) Operating temp. & humidity Size & weight 100A Continuous at 45 to 65 Hz 25 mV/A AC Output voltage Approx. 74W × 145H × 42D mm, 340 g Approx. 65W × 52H × 18D mm, 50 g NOTES: 1. Voltage to ground is that voltage between a power line and earth ground in a groundingdependent electric circuit, or the voltage between one power line and any other power line in a grounding-independent circuit. 2. Coordination of Insulation: determination of the safe and appropriate characteristics of electrical insulation of wiring and connected devices according to the operating voltage. 3. Model 9658 is suitable for coordination of insulation with circuits of up to 150V voltage to ground, up to 240V for 3P3W lines, and up to 120/240V for 3P4W lines. 4. Models 9657 and 9659 are suitable for coordination of insulation with circuits of up to 300V voltage to ground, up to 500V for 3P3W lines, and up to 277/480V for 3P4W lines. Approx. 358W × 108H × 48D mm, 2.5 kg COMMON ELECTRIC CIRCUITS and COORDINATION of INSULATION 3P-4W (3-phase, 4-wire) Voltage 120/208 V 120/240 V 230/400 V 277/480 V 3P-3W (3-phase, 3-wire) Voltage Voltage to Ground CATIII Recommended Impulse Withstand Voltage 240 V 150 V 2500 V 500 V 300 V 4000 V (From EN61010-2-032, Annexes J, Table J.1) Model 3638-20 LEAK LOGGER ■ Options Model 3911-20 COMMUNICATION BASE Model 9657 CLAMP ON LEAK SENSOR Model 9658 CLAMP ON LEAK SENSOR Model 9659 CLAMP ON LEAK SENSOR Model 9637 RS-232C CABLE (9-pin to 9-pin crossover, 1.8 m) Model 9638 RS-232C CABLE (9-pin to 25-pin crossover, 1.8 m) DISTRIBUTED BY HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp ASM GmbH Am Bleichbach 18 - 22 85452 Moosinning All information correct as of Apr. 20, 2001. All specifications are subject to change without notice. ■ Inter net HIOKI website h t t p : / / w w w . h i o k i . c o . j p / 363820E2-14M-05P Printed in Japan