BEL 0RCM

ISOLATED DC/DC CONVERTERS
48 VDC Input 12 VDC/27 A Output, 1/4 Brick
0RCM-27S12L
RoHS Compliant
•
Industry standard quarter-brick package
•
Up to 300 W at 95% efficiency
•
1500 V isolation
•
Safety Agency Approvals
Rev.A
Description
The 0RCM-27S “Cimarron” Series are isolated DC/DC converters that operate from a nominal 48 VDC source.
These converters use a full bridge power train to provide isolation and step down. These units will provide up to
300 W of output power from a nominal 48 VDC input. These units are designed to be highly efficient and low cost.
Features include remote on/off, over current protection and under voltage lockout. These converters are provided
in an industry standard quarter-brick package.
Part Selection
Output
Voltage
Input Voltage
Max. Output
Current
Max. Output
Power
Typical
Efficiency
Model Number
12 Vdc
48 Vdc
27 A
300 W
95%
0RCM-27S12L
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Input Specifications
Parameter
Min
Typ
Max
36 V
-
55 V
Input Current (no load)
-
-
110 mA
Input Current (full load)
-
-
6.82 A
Reflected Ripple Current (rms)
-
-
50 mA
Reflected Ripple Current (pk-pk)
-
-
100 mA
-
35.8 V
33.8 V
57.1 V
-
Input Voltage Range
Notes
with a 12uH source inductor at nom. Vin
and full load.
Under-voltage Lockout
Turn-on
Turn off
Over-voltage Lockout
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 VDC Input 12 VDC/27 A Output, 1/4 Brick
Output Specifications
Parameter
Output Voltage
36Vin
48Vin
55Vin
Output Current
Output Power
Load Regulation
Min
Typ
Max
0A
-
8.7 V
11.7 V
13.3 V
-
27 A
300 W
0.4 V
-
-
150 mV
100 uF
(50mohm)
-
3000 uF
-
150 mV
50 uS
250 mV
100 uS
Ripple and Noise (pk-pk)
Load Capacitance
Transient Response
Max deviation
Recovery to within ± 1%
Notes
Setpoint at no load.
0 to 20 MHz Bandwidth, use 1.0 uF ceramic
cap and 100 uF/50mOhm tantalum on
output
di/dt =0 .1 A/uS, Vin =48 V
Ta = 25 °C, 25% load change.
General Specifications
Min
Typ
Switching Frequency
-
96 kHz
-
Weight
-
TBD
-
Operating Temperature
-40 °C
-
70 °C
Non-Operating Temperature
-55 °C
-
125 °C
-
120 °C
-
Parameter
Overtemp Shutdown
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Protection Features
Short circuit
Over current
Undervoltage
Overvoltage
Remote On/Off
Active Low
(Optional Active High)
Turn on delay
Outupt voltage rise time
Safety Agency Approvals
(pending)
Max
Notes
fixed
10 °C hysteresis measured on Q4
2.28 x 1.45 x 0.50
57.9 x 36.8 x 12.7
Latching
110% to 125% max Io
UVLO Vin < 35.0
OVSD Vin>57.0
0V
1.0 V
-
2.7 ms
4.3 ms
0.4 V
18 V
-
UL / cUL Recognized Certified to EN60950
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 VDC Input 12 VDC/27 A Output, 1/4 Brick
Mechanical Drawing
Pin Connections
Pin
Function
1
+ Vin
2
Remote On/Off
3
- Vin
4
- Vout
5
+ Vout
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2008 Bel Fuse Inc. Specifications subject to change without notice. 110308
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com