CIRRUS CS2300P-CZZ

CS2300-OTP
Fractional-N Clock Multiplier with Internal LCO
Features
General Description
 Clock Multiplier / Jitter Reduction
The CS2300-OTP is an extremely versatile system
clocking device that utilizes a programmable phase lock
loop. The CS2300-OTP is based on a hybrid analogdigital PLL architecture comprised of a unique combination of a Delta-Sigma Fractional-N Frequency
Synthesizer and a Digital PLL. This architecture allows
for generation of a low-jitter clock relative to an external
noisy synchronization clock with frequencies as low as
50 Hz. The CS2300-OTP has many configuration options which are set once prior to runtime. At runtime
there are three hardware configuration pins available for
mode and feature selection.
–
Generates a Low Jitter 6 - 75 MHz Clock
from a Jittery or Intermittent 50 Hz to
30 MHz Clock Source
 Internal LCO Reference Clock
 Highly Accurate PLL Multiplication Factor
–
Maximum Error Less Than 1 PPM in HighResolution Mode
 One-Time Programmability
–
–
Configurable Hardware Control Pins
Configurable Auxiliary Output
 Minimal Board Space Required
–
No External Analog Loop-filter
Components
The CS2300-OTP is available in a 10-pin MSOP package in Commercial (-10°C to +70°C) grade. Customer
development kits are also available for custom device
prototyping, small production programming, and device
evaluation. Please see “Ordering Information” on
page 27 for complete details.
3.3 V
Frequency Reference
Hardware Control
PLL Output
Hardware Configuration
Lock Indicator
LCO
Fractional-N
Frequency Synthesizer
Auxiliary
Output
6 to 75 MHz
PLL Output
N
50 Hz to 30 MHz
Frequency Reference
Output to Input
Clock Ratio
Preliminary Product Information
http://www.cirrus.com
Digital PLL & Fractional
N Logic
This document contains information for a new product.
Cirrus Logic reserves the right to modify this product without notice.
Copyright © Cirrus Logic, Inc. 2008
(All Rights Reserved)
JUN '08
DS844PP1
CS2300-OTP
TABLE OF CONTENTS
1. PIN DESCRIPTION ................................................................................................................................. 4
2. TYPICAL CONNECTION DIAGRAM ..................................................................................................... 5
3. CHARACTERISTICS AND SPECIFICATIONS ...................................................................................... 6
RECOMMENDED OPERATING CONDITIONS .................................................................................... 6
ABSOLUTE MAXIMUM RATINGS ........................................................................................................ 6
DC ELECTRICAL CHARACTERISTICS ................................................................................................ 6
AC ELECTRICAL CHARACTERISTICS ................................................................................................ 7
4. ARCHITECTURE OVERVIEW ............................................................................................................... 8
4.1 Delta-Sigma Fractional-N Frequency Synthesizer ........................................................................... 8
4.2 Hybrid Analog-Digital Phase Locked Loop ...................................................................................... 8
5. APPLICATIONS ................................................................................................................................... 10
5.1 One Time Programmability ............................................................................................................ 10
5.2 Timing Reference Clock ................................................................................................................. 10
5.3 Frequency Reference Clock Input, CLK_IN ................................................................................... 10
5.3.1 CLK_IN Skipping Mode ......................................................................................................... 10
5.3.2 Adjusting the Minimum Loop Bandwidth for CLK_IN ............................................................ 12
5.4 Output to Input Frequency Ratio Configuration ............................................................................. 13
5.4.1 User Defined Ratio (RUD) ..................................................................................................... 13
5.4.2 Manual Ratio Modifier (R-Mod) ............................................................................................. 14
5.4.3 Automatic Ratio Modifier (Auto R-Mod) ................................................................................ 14
5.4.4 Effective Ratio (REFF) .......................................................................................................... 15
5.4.5 Ratio Configuration Summary ............................................................................................... 15
5.5 PLL Clock Output ........................................................................................................................... 16
5.6 Auxiliary Output .............................................................................................................................. 17
5.7 Mode Pin Functionality ................................................................................................................... 17
5.7.1 M1 and M0 Mode Pin Functionality ....................................................................................... 17
5.7.2 M2 Mode Pin Functionality .................................................................................................... 18
5.7.2.1 M2 Configured as Output Disable .............................................................................. 18
5.7.2.2 M2 Configured as R-Mod Enable .............................................................................. 18
5.7.2.3 M2 Configured as Auto R-Mod Enable ...................................................................... 18
5.7.2.4 M2 Configured as AuxOutSrc Override ..................................................................... 18
5.8 Clock Output Stability Considerations ............................................................................................ 19
5.8.1 Output Switching ................................................................................................................... 19
5.8.2 PLL Unlock Conditions .......................................................................................................... 19
6. PARAMETER DESCRIPTIONS ........................................................................................................... 20
6.1 Modal Configuration Sets ............................................................................................................... 20
6.1.1 R-Mod Selection (RModSel[1:0]) ........................................................................................... 20
6.1.2 Auxiliary Output Source Selection (AuxOutSrc[1:0]) ............................................................. 21
6.1.3 Auto R-Modifier Enable (AutoRMod) ..................................................................................... 21
6.2 Ratio 0 - 3 ...................................................................................................................................... 21
6.3 Global Configuration Parameters ................................................................................................... 21
6.3.1 Clock Skip Enable (ClkSkipEn) ............................................................................................. 21
6.3.2 AUX PLL Lock Output Configuration (AuxLockCfg) .............................................................. 22
6.3.3 Enable PLL Clock Output on Unlock (ClkOutUnl) ................................................................. 22
6.3.4 Low-Frequency Ratio Configuration (LFRatioCfg) ................................................................ 22
6.3.5 M2 Pin Configuration (M2Config[2:0]) ................................................................................... 22
6.3.6 Clock Input Bandwidth (ClkIn_BW[2:0]) ................................................................................ 23
7. CALCULATING THE USER DEFINED RATIO .................................................................................... 24
7.1 High Resolution 12.20 Format ....................................................................................................... 24
7.2 High Multiplication 20.12 Format ................................................................................................... 24
8. PROGRAMMING INFORMATION ........................................................................................................ 25
9. PACKAGE DIMENSIONS .................................................................................................................... 26
DS844PP1
2
CS2300-OTP
THERMAL CHARACTERISTICS ......................................................................................................... 26
10. ORDERING INFORMATION .............................................................................................................. 27
11. REVISION HISTORY .......................................................................................................................... 27
LIST OF FIGURES
Figure 1. Typical Connection Diagram ........................................................................................................ 5
Figure 2. Delta-Sigma Fractional-N Frequency Synthesizer ....................................................................... 8
Figure 3. Hybrid Analog-Digital PLL ............................................................................................................ 9
Figure 4. External Component Requirements for LCO ............................................................................. 10
Figure 5. CLK_IN removed for > 223 LCO cycles ..................................................................................... 11
Figure 6. CLK_IN removed for < 223 LCO cycles but > tCS ..................................................................... 11
Figure 7. CLK_IN removed for < tCS ........................................................................................................ 12
Figure 8. Low bandwidth and new clock domain ...................................................................................... 12
Figure 9. High bandwidth with CLK_IN domain re-use ............................................................................. 13
Figure 10. Ratio Feature Summary ........................................................................................................... 16
Figure 11. PLL Clock Output Options ....................................................................................................... 16
Figure 12. Auxiliary Output Selection ........................................................................................................ 17
Figure 13. M2 Mapping Options ................................................................................................................ 18
Figure 14. Parameter Configuration Sets .................................................................................................. 20
LIST OF TABLES
Table 1. Modal and Global Configuration .................................................................................................. 10
Table 2. Ratio Modifier .............................................................................................................................. 14
Table 3. Automatic Ratio Modifier ............................................................................................................. 14
Table 4. Example Audio Oversampling Clock Generation from CLK_IN .................................................. 15
Table 5. Example 12.20 R-Values ............................................................................................................ 24
Table 6. Example 20.12 R-Values ............................................................................................................ 24
DS844PP1
3
CS2300-OTP
1. PIN DESCRIPTION
VD
1
10
M0
GND
2
9
M1
CLK_OUT
3
8
M2
AUX_OUT
4
7
FILTN
CLK_IN
5
6
FILTP
Pin Name
#
Pin Description
VD
1
Digital Power (Input) - Positive power supply for the digital and analog sections.
GND
2
Ground (Input) - Ground reference.
CLK_OUT
3
PLL Clock Output (Output) - PLL clock output.
AUX_OUT
4
Auxiliary Output (Output) - This pin outputs a buffered version of one of the input or output clocks,
or a status signal, depending on configuration.
CLK_IN
5
Frequency Reference Clock Input (Input) - Clock input for the Digital PLL frequency reference.
FILTP
FILTN
6
7
LCO Filter Connections (Input/Output) - These pins provide external supply filtering for the LCO.
M2
8
Mode Select (Input) - M2 is a configurable mode selection pin.
M1
9
Mode Select (Input) - M1 is a configurable mode selection pin.
M0
10 Mode Select (Input) - M0 is a configurable mode selection pin.
4
DS844PP1
CS2300-OTP
2. TYPICAL CONNECTION DIAGRAM
0.1 µF
1 µF
+3.3 V
VD
M2
System Microcontroller
M1
M0
CS2300-OTP
Frequency Reference
CLK_IN
0.1 µF
FILTP
CLK_OUT
To circuitry which requires
a low-jitter clock
AUX_OUT
To other circuitry or
Microcontroller
FILTN
GND
Figure 1. Typical Connection Diagram
DS844PP1
5
CS2300-OTP
3. CHARACTERISTICS AND SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS
GND = 0 V; all voltages with respect to ground. (Note 1)
Parameters
DC Power Supply
Symbol
Min
Typ
Max
Units
VD
3.1
3.3
3.5
V
TAC
-10
-
+70
°C
Ambient Operating Temperature (Power Applied)
Commercial Grade
Notes: 1. Device functional operation is guaranteed within these limits. Functionality is not guaranteed or implied
outside of these limits. Operation outside of these limits may adversely affect device reliability.
ABSOLUTE MAXIMUM RATINGS
GND = 0 V; all voltages with respect to ground.
Parameters
Symbol
Min
Max
Units
DC Power Supply
VD
-0.3
6.0
V
Input Current
IIN
-
±10
mA
Digital Input Voltage (Note 1)
VIN
-0.3
VD + 0.4
V
Ambient Operating Temperature (Power Applied)
TA
-55
125
°C
Storage Temperature
Tstg
-65
150
°C
WARNING: Operation at or beyond these limits may result in permanent damage to the device.
Notes: 1. The maximum over/under voltage is limited by the input current except on the power supply pin.
DC ELECTRICAL CHARACTERISTICS
Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; TA = -10°C to +70°C (Commercial Grade).
Parameters
Symbol
Min
Typ
Max
Units
Power Supply Current - Unloaded
(Note 2)
ID
-
18
23
mA
Power Dissipation - Unloaded
(Note 2)
PD
-
59
76
mW
Input Leakage Current
IIN
-
-
±10
µA
Input Capacitance
IC
-
8
-
pF
High-Level Input Voltage
VIH
70%
-
-
VD
Low-Level Input Voltage
VIL
-
-
30%
VD
High-Level Output Voltage (IOH = -1.2 mA)
VOH
80%
-
-
VD
Low-Level Output Voltage (IOH = 1.2 mA)
VOL
-
-
20%
VD
Notes: 2. To calculate the additional current consumption due to loading (per output pin), multiply clock output
frequency by load capacitance and power supply voltage.
For example, fCLK_OUT (49.152 MHz) * CL(15 pF) * VD (3.3 V) = 2.4 mA of additional current due to
these loading conditions on CLK_OUT.
6
DS844PP1
CS2300-OTP
AC ELECTRICAL CHARACTERISTICS
Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; TA = -10°C to +70°C (Commercial Grade);
CL = 15 pF.
Parameters
Symbol
Min
Typ
Max
Units
50 Hz
-
30
MHz
Auto R Modifier = 1
Auto R Modifier = 0.5
Auto R Modifier = 0.25
4
72
168
-
59
138
256
kHz
kHz
kHz
pwCLK_IN
fCLK_IN < 175 kHz
fCLK_IN > 175 kHz
140
10
-
-
ns
ns
tCS
(Notes 3, 4)
20
-
-
ms
Clock Skipping Input Frequency
fCLK_SKIP
(Note 4)
50 Hz
-
80
kHz
PLL Clock Output Frequency
fCLK_OUT
6
-
75
MHz
Clock Input Frequency (Auto R-Mod Disabled)
fCLK_IN
Clock Input Frequency (Auto R-mod Enabled)
fCLK_IN
Clock Input Pulse Width
Clock Skipping Timeout
Conditions
PLL Clock Output Duty Cycle
tOD
Measured at VD/2
48
50
52
%
Clock Output Rise Time
tOR
20% to 80% of VD
-
1.7
3.0
ns
Clock Output Fall Time
tOF
80% to 20% of VD
-
1.7
3.0
ns
Period Jitter
tJIT
(Note 5)
-
35
110
ps rms
Base Band Jitter (100 Hz to 40 kHz)
(Notes 5, 6)
-
50
-
ps rms
Wide Band JItter (100 Hz Corner)
(Notes 5, 7)
-
150
-
ps rms
fCLK_IN < 200 kHz
fCLK_IN > 200 kHz
-
100
1
200
3
UI
ms
PLL Lock Time - CLK_IN (Note 8)
tLC
Notes: 3. tCS represents the time from the removal of CLK_IN by which CLK_IN must be re-applied to ensure that
PLL_OUT continues while the PLL re-acquires lock. This timeout is based on the internal VCO frequency, with the minimum timeout occurring at the maximum VCO frequency. Lower VCO frequencies will
result in larger values of tCS.
4. Only valid in clock skipping mode; See “CLK_IN Skipping Mode” on page 10 for more information.
5. fCLK_OUT = 24.576 MHz; Sample size = 10,000 points; AuxOutSrc[1:0] = 11.
6. In accordance with AES-12id-2006 section 3.4.2. Measurements are Time Interval Error taken with 3rd
order 100 Hz to 40 kHz bandpass filter.
7. In accordance with AES-12id-2006 section 3.4.1. Measurements are Time Interval Error taken with 3rd
order 100 Hz Highpass filter.
8. 1 UI (unit interval) corresponds to tCLK_IN or 1/fCLK_IN.
DS844PP1
7
CS2300-OTP
4. ARCHITECTURE OVERVIEW
4.1
Delta-Sigma Fractional-N Frequency Synthesizer
The core of the CS2300 is a Delta-Sigma Fractional-N Frequency Synthesizer which has very high-resolution for Input/Output clock ratios, low phase noise, very wide range of output frequencies and the ability to
quickly tune to a new frequency. In very simplistic terms, the Fractional-N Frequency Synthesizer multiplies
the LC Oscillator (LCO) by the value of N to generate the PLL output clock. The desired output to input clock
ratio is the value of N that is applied to the delta-sigma modulator (see Figure 2).
The analog PLL based frequency synthesizer uses a low-jitter timing reference clock, the LCO, as a time
and phase reference for the internal voltage controlled oscillator (VCO). The phase comparator compares
the fractional-N divided clock with the original timing reference and generates a control signal. The control
signal is filtered by the internal loop filter to generate the VCO’s control voltage which sets its output frequency. The delta-sigma modulator modulates the loop integer divide ratio to get the desired fractional ratio
between the reference clock and the VCO output (thus the duty cycle of the modulator sets the fractional
value). This allows the design to be optimized for very fast lock times for a wide range of output frequencies
without the need for external filter components.
LC Oscillator
Phase
Comparator
Internal
Loop Filter
Voltage Controlled
Oscillator
PLL Output
Fractional-N
Divider
Delta-Sigma
Modulator
N
Figure 2. Delta-Sigma Fractional-N Frequency Synthesizer
4.2
Hybrid Analog-Digital Phase Locked Loop
The addition of the Digital PLL and Fractional-N Logic (shown in Figure 3) to the Fractional-N Frequency
Synthesizer creates the Hybrid Analog-Digital Phase Locked Loop with many advantages over classical analog PLL techniques. These advantages include the ability to operate over extremely wide frequency ranges
without the need to change external loop filter components while maintaining impressive jitter reduction performance. In the Hybrid architecture, the Digital PLL calculates the ratio of the PLL output clock to the frequency reference and compares that to the desired ratio. The digital logic generates a value of N which is
then applied to the Fractional-N frequency synthesizer to generate the desired PLL output frequency. Notice
that the frequency and phase of the LCO does not affect the output of the PLL since the digital control loop
will correct for the PLL output. A major advantage of the Digital PLL is the ease with which the loop filter
bandwidth can be altered. The PLL bandwidth is set to a wide-bandwidth mode to quickly achieve lock and
then reduced for optimal jitter rejection.
8
DS844PP1
CS2300-OTP
Delta-Sigma Fractional-N Frequency Synthesizer
LCO
Phase
Comparator
Internal
Loop Filter
Voltage Controlled
Oscillator
PLL Output
Fractional-N
Divider
Delta-Sigma
Modulator
Digital PLL and Fractional-N Logic
N
Digital Filter
Frequency Reference
Clock
Frequency
Comparator for
Frac-N Generation
Output to Input Ratio for Hybrid mode
Figure 3. Hybrid Analog-Digital PLL
DS844PP1
9
CS2300-OTP
5. APPLICATIONS
5.1
One Time Programmability
The one time programmable (OTP) circuitry in the CS2300-OTP allows for pre-configuration of the device
prior to use in a system. There are two types of parameters that are used for device pre-configuration: modal
and global. The modal parameters are features which, when grouped together, create a modal configuration
set (see Figure 14 on page 20). Up to four modal configuration sets can be permanently stored and then
dynamically selected using the M[1:0] mode select pins (see Table 1). The global parameters are the remaining configuration settings which do not change with the mode select pins. The modal and global parameters can be pre-set at the factory or user programmed using the customer development kit, CDK2000;
Please see “Programming Information” on page 25 for more details.
Parameter Type
M[1:0] pins = 00
M[1:0] pins = 01
M[1:0] pins = 10
M[1:0] pins = 11
Modal
Configuration Set 0
Ratio 0
Configuration Set 1
Ratio 1
Configuration Set 2
Ratio 2
Configuration Set 3
Ratio 3
Global
Configuration settings set once for all modes.
Table 1. Modal and Global Configuration
5.2
Timing Reference Clock
The internal LC oscillator is used to generate the timing reference clock. A single 0.1 µF cap must be connected between the FILTP and FILTN pins and FILTN must be connected to ground as shown in Figure 4.
FILTN
FILTP
0.1 µF
Figure 4. External Component Requirements for LCO
5.3
Frequency Reference Clock Input, CLK_IN
The frequency reference clock input (CLK_IN) is used by the Digital PLL and Fractional-N Logic block to
dynamically generate a fractional-N value for the Frequency Synthesizer (see “Hybrid Analog-Digital PLL”
on page 9). The Digital PLL first compares the CLK_IN frequency to the PLL output. The Fractional-N logic
block then translates the desired ratio based off of CLK_IN to one based off of the internal LCO. This allows
the low-jitter internal LCO to be used as the clock which the Frequency Synthesizer multiplies while maintaining synchronicity with the frequency reference clock through the Digital PLL. The allowable frequency
range for CLK_IN is found in the “AC Electrical Characteristics” on page 7.
5.3.1
CLK_IN Skipping Mode
CLK_IN skipping mode allows the PLL to maintain lock even when the CLK_IN signal has missing pulses
for up to 20 ms (tCS) at a time (see “AC Electrical Characteristics” on page 7 for specifications). CLK_IN
skipping mode can only be used when the CLK_IN frequency is below 80 kHz. The ClkSkipEn global parameter enables this function.
10
DS844PP1
CS2300-OTP
Regardless of the setting of the ClkSkipEn parameter the PLL output will continue for 223 LCO cycles
(518 ms to 634 ms) after CLK_IN is removed (see Figure 5). This is true as long as CLK_IN does not glitch
or have an effective change in period as the clock source is removed, otherwise the PLL will interpret this
as a change in frequency causing clock skipping and the 223 LCO cycle time-out to be bypassed and the
PLL to immediately unlock. If the prior conditions are met while CLK_IN is removed and 223 LCO cycles
pass, the PLL will unlock and the PLL_OUT state will be determined by the ClkOutUnl parameter; See
“PLL Clock Output” on page 16. If CLK_IN is re-applied after such time, the PLL will remain unlocked for
the specified time listed in the “AC Electrical Characteristics” on page 7 after which lock will be acquired
and the PLL output will resume.
223 LCO cycles
223 LCO cycles
Lock Time
Lock Time
CLK_IN
ClkSkipEn=0 or 1
ClkOutUnl=0
CLK_IN
ClkSkipEn=0 or 1
ClkOutUnl=1
PLL_OUT
UNLOCK
PLL_OUT
UNLOCK
= invalid clocks
Figure 5. CLK_IN removed for > 223 LCO cycles
f CLK_IN is removed and then reapplied within 223 LCO cycles but later than tCS, the ClkSkipEn parameter will have no effect and the PLL output will continue until CLK_IN is re-applied (see Figure 6). Once
CLK_IN is re-applied, the PLL will go unlocked only for the time it takes to acquire lock; the PLL_OUT
state will be determined by the ClkOutUnl parameter during this time.
223 LCO cycles
223 LCO cycles
tCS
tCS
Lock Time
Lock Time
CLK_IN
ClkSkipEn=0 or 1
ClkOutUnl=0
PLL_OUT
UNLOCK
CLK_IN
ClkSkipEn=0 or 1
ClkOutUnl=1
PLL_OUT
UNLOCK
= invalid clocks
Figure 6. CLK_IN removed for < 223 LCO cycles but > tCS
If CLK_IN is removed and then re-applied within tCS, the ClkSkipEn parameter determines whether
PLL_OUT continues while the PLL re-acquires lock (see Figure 7). When ClkSkipEn is disabled and
CLK_IN is removed the PLL output will continue until CLK_IN is re-applied at which point the PLL will go
unlocked only for the time it takes to acquire lock; the PLL_OUT state will be determined by the ClkOutUnl
parameter during this time. When ClkSkipEn is enabled and CLK_IN is removed the PLL output clock will
DS844PP1
11
CS2300-OTP
remain continuous throughout the missing CLK_IN period including the time while the PLL re-acquires
lock.
tCS
tCS
Lock Time
CLK_IN
ClkSkipEn=1
ClkOutUnl=0 or 1
CLK_IN
ClkSkipEn=0
ClkOutUnl=1
PLL_OUT
UNLOCK
PLL_OUT
UNLOCK
= invalid clocks
Lock Time
tCS
CLK_IN
ClkSkipEn=0
ClkOutUnl=0
PLL_OUT
UNLOCK
Figure 7. CLK_IN removed for < tCS
Referenced Control
Parameter Definition
ClkSkipEn..............................“Clock Skip Enable (ClkSkipEn)” on page 21
ClkOutUnl..............................“Enable PLL Clock Output on Unlock (ClkOutUnl)” on page 22
5.3.2
Adjusting the Minimum Loop Bandwidth for CLK_IN
The CS2300 allows the minimum loop bandwidth of the Digital PLL to be adjusted between 1 Hz and
128 Hz using the ClkIn_BW[2:0] global parameter. The minimum loop bandwidth of the Digital PLL directly affects the jitter transfer function; specifically, jitter frequencies below the loop bandwidth corner are
passed from the PLL input directly to the PLL output without attenuation. In some applications it is desirable to have a very low minimum loop bandwidth to reject very low jitter frequencies, commonly referred
to as wander. In others it may be preferable to remove only higher frequency jitter, allowing the input wander to pass through the PLL without attenuation.
Typically, applications in which the PLL_OUT signal creates a new clock domain from which all other system clocks and associated data are derived will benefit from the maximum jitter and wander rejection of
the lowest PLL bandwidth setting. See Figure 8.
PLL
BW = 1 Hz
CLK_IN
Wander > 1 Hz
PLL_OUT
Wander and Jitter > 1 Hz Rejected
MCLK
Jitter
MCLK
or
Subclocks generated
from new clock domain.
LRCK
LRCK
SCLK
SCLK
SDATA
D0
D1
SDATA
D0
D1
Figure 8. Low bandwidth and new clock domain
Systems in which some clocks and data are derived from the PLL_OUT signal while other clocks and data
are derived from the CLK_IN signal will often require phase alignment of all the clocks and data in the
system. See Figure 9. If there is substantial wander on the CLK_IN signal in these applications, it may be
necessary to increase the minimum loop bandwidth allowing this wander to pass through to the CLK_OUT
12
DS844PP1
CS2300-OTP
signal in order to maintain phase alignment. For these applications, it is advised to experiment with the
loop bandwidth settings and choose the lowest bandwidth setting that does not produce system timing
errors due to wandering between the clocks and data synchronous to the CLK_IN domain and those synchronous to the PLL_OUT domain.
PLL
BW = 128 Hz
CLK_IN
Wander < 128 Hz
PLL_OUT
Jitter > 128 Hz Rejected
Wander < 128 Hz Passed to Output
MCLK
Jitter
MCLK
or
Subclocks and data re-used
from previous clock domain.
LRCK
LRCK
SCLK
SCLK
SDATA
D0
D1
SDATA
D0
D1
Figure 9. High bandwidth with CLK_IN domain re-use
While acquiring lock, the digital loop bandwidth is automatically set to a large value. Once lock is
achieved, the digital loop bandwidth will settle to the minimum value selected by the ClkIn_BW[2:0] parameter.
Referenced Control
Parameter Definition
ClkIn_BW[2:0] .......................“Clock Input Bandwidth (ClkIn_BW[2:0])” on page 23
5.4
5.4.1
Output to Input Frequency Ratio Configuration
User Defined Ratio (RUD)
The User Defined Ratio, RUD, is a 32-bit un-signed fixed-point number which determines the basis for the
desired input to output clock ratio. Up to four different ratios, Ratio0-3, can be stored in the CS2300’s one
time programmable memory. Selection between the four ratios is achieved by the M[1:0] mode select
pins. The 32-bit RUD can be expressed in either a high resolution (12.20) or high multiplication (20.12)
format selectable by the LFRatioCfg global parameter.
The RUD for high resolution (12.20) format is encoded with 12 MSBs representing the integer binary portion with the remaining 20 LSBs representing the fractional binary portion. The maximum multiplication
factor is approximately 4096 with a resolution of 0.954 PPM in this configuration. See “Calculating the
User Defined Ratio” on page 24 for more information.
The RUD for high multiplication (20.12) format is encoded with 20 MSBs representing the integer binary
portion with the remaining 12 LSBs representing the fractional binary portion. In this configuration, the
maximum multiplication factor is approximately 1,048,575 with a resolution of 244 PPM. It is recommended that the 12.20 High-Resolution format be utilized whenever the desired ratio is less than 4096 since
the output frequency accuracy of the PLL is directly proportional to the accuracy of the timing reference
clock and the resolution of the RUD.
Referenced Control
Parameter Definition
Ratio 0-3................................“Ratio 0 - 3” on page 21
LFRatioCfg ............................“Low-Frequency Ratio Configuration (LFRatioCfg)” on page 22
M[1:0] ....................................“M1 and M0 Mode Pin Functionality” on page 17
DS844PP1
13
CS2300-OTP
5.4.2
Manual Ratio Modifier (R-Mod)
The manual Ratio Modifier is used to internally multiply/divide the currently addressed RUD (Ratio0-3
stored in the register space remain unchanged). The available options for R-Mod are summarized in
Table 2 on page 14. R-Mod is enabled via the M2 pin in conjunction with the appropriate setting of the
M2Config[2:0] global parameter (see Section 5.7.2 on page 18).
RModSel[1:0]
R Modifier
00
0.5
01
0.25
10
0.125
11
0.0625
Table 2. Ratio Modifier
Referenced Control
Parameter Definition
Ratio 0-3................................“Ratio 0 - 3” on page 21
RModSel[1:0] ........................“R-Mod Selection (RModSel[1:0])” section on page 20
M2Config[2:0]........................“M2 Pin Configuration (M2Config[2:0])” on page 22
5.4.3
Automatic Ratio Modifier (Auto R-Mod)
The Automatic R-Modifier uses the CLK_IN Frequency Range Detector to implement a frequency dependent multiply of the currently addressed RUD as shown in Table 3. The CLK_IN Frequency Range Detector determines the ratio between the frequency of the internal SysClk and the CLK_IN input signal. The
result of the ratio measurement is the internal status signal called FsDetect[1:0].
Like with R-Mod, the Ratio0-3 parameters stored in the one time programmable memory remain unchanged. The Automatic Ratio Modifier is enabled either by the AutoRMod modal parameter or via the
M2 pin in conjunction with the appropriate setting of the M2Config[2:0] global parameter (see Section
5.7.2 on page 18).
FsDetect[1:0]
fSysClk / fCLK_IN
Auto R Modifier
00
> 224
1
01
96 - 224
0.5
10
< 96
0.25
Table 3. Automatic Ratio Modifier
It is important to note that Auto R-Mod (if enabled) is applied in addition to any R-Mod already selected
by the RModSel[1:0] modal parameter and is used to calculate the Effective Ratio (see Section 5.4.4 on
page 15).
Auto R-Mod can be used to generate the appropriate oversampling clock (MCLK) for audio A/D and D/A
converters. For example, if the clock applied to CLK_IN is the audio sample rate, Fs (also known as the
word, frame or Left/Right clock), SysClk is the internal LCO (between 13.23 MHz and 16.17 MHz), FsDe-
14
DS844PP1
CS2300-OTP
tect[1:0] would then reflect the frequency range of the audio sample rate. An RUD of 512 generates the
audio oversampling clocks as shown in Table 4.
Speed Mode (used for
audio converters)
Audio Oversampling
Clock
< [59 to 72] kHz
Single Speed
512 x
>[59 to 72] kHz
and
<[138 to 168] kHz
Double Speed
256 x
> [138 to 168] kHz
Quad Speed
128 x
FsDetect[1:0]
Inferred Audio Sample Rate
00
01
10
Table 4. Example Audio Oversampling Clock Generation from CLK_IN
Referenced Control
Parameter Definition
Ratio 0-3................................“Ratio 0 - 3” on page 21
RModSel[1:0] ........................“R-Mod Selection (RModSel[1:0])” section on page 20
AutoRMod .............................“Auto R-Modifier Enable (AutoRMod)” on page 21
M2Config[2:0]........................“M2 Pin Configuration (M2Config[2:0])” on page 22
5.4.4
Effective Ratio (REFF)
The Effective Ratio (REFF) is an internal calculation comprised of RUD and the appropriate modifiers, as
previously described. REFF is calculated as follows:
REFF = RUD • R-Mod • Auto R-Mod
Ratio modifiers which would produce an overflow or truncation of REFF should not be used. In all cases,
the maximum and minimum allowable values for REFF are dictated by the frequency limits for both the
input and output clocks as shown in the “AC Electrical Characteristics” on page 7.
Selection of the user defined ratio from the four stored ratios is made by using the M[1:0] pins.
Referenced Control
Parameter Definition
M[1:0] pins.............................“M1 and M0 Mode Pin Functionality” on page 17
5.4.5
Ratio Configuration Summary
The RUD is the user defined ratio for which up to four different values (Ratio0-3) can be stored in the one
time programmable memory. The M[1:0] pins then select the user defined ratio to be used as well as the
modal configuration set. The resolution/format for the RUD is selectable. R-Mods are applied according to
their settings. The user defined ratio, ratio modifier, and automatic ratio modifier make up the effective
DS844PP1
15
CS2300-OTP
ratio REFF, the final calculation used to determine the output to input clock ratio. The conceptual diagram
in Figure 10 summarizes the features involved in the calculation of the ratio values used to generate the
fractional-N value which controls the Frequency Synthesizer. The subscript ‘4’ indicates the modal parameters.
LCO
Effective Ratio REFF
M2 pin
M[1:0] pins
User Defined Ratio RUD
Frequency
Synthesizer
RModSel[1:0]4
Ratio 0
PLL Output
Ratio Format
Ratio 1
12.20
20.12
Ratio 2
Ratio
Modifier
Auto
R-Mod
Dynamic Ratio, ‘N’
Digital PLL &
Fractional N Logic
Ratio 3
LFRatioCfg
AutoRMod4
or M2 pin
FsDet[1:0]
Frequency Reference Clock
(CLK_IN)
Figure 10. Ratio Feature Summary
Referenced Control
Parameter Definition
Ratio 0-3................................“Ratio 0 - 3” on page 21
M[1:0] pins.............................“M1 and M0 Mode Pin Functionality” on page 17
LFRatioCfg ............................“Low-Frequency Ratio Configuration (LFRatioCfg)” on page 22
RModSel[1:0] ........................“R-Mod Selection (RModSel[1:0])” section on page 20
AutoRMod .............................“Auto R-Modifier Enable (AutoRMod)” on page 21
5.5
PLL Clock Output
The PLL clock output pin (CLK_OUT) provides a buffered version of the output of the frequency synthesizer.
The driver can be set to high-impedance with the M2 pin when the M2Config[1:0] global parameter is set to
either 000 or 010. The output from the PLL automatically drives a static low condition while the PLL is unlocked (when the clock may be unreliable). This feature can be disabled by setting the ClkOutUnl global
parameter, however the state CLK_OUT may then be unreliable during an unlock condition.
ClkOutUnl
PLL Locked/Unlocked
0
0
2:1 Mux
M2 pin with
M2Config[1:0] = 000, 010
0
1
2:1 Mux
PLL Output
PLL Clock Output
PLLClkOut
PLL Clock Output Pin
(CLK_OUT)
1
Figure 11. PLL Clock Output Options
Referenced Control
Parameter Definition
ClkOutUnl..............................“Enable PLL Clock Output on Unlock (ClkOutUnl)” on page 22
ClkOutDis ..............................“M2 Configured as Output Disable” on page 18
M2Config[2:0]........................“M2 Pin Configuration (M2Config[2:0])” on page 22
16
DS844PP1
CS2300-OTP
5.6
Auxiliary Output
The auxiliary output pin (AUX_OUT) can be mapped, as shown in Figure 12, to one of three signals: input
clock (CLK_IN), additional PLL clock output (CLK_OUT), or a PLL lock indicator (Lock). The mux is controlled via the AuxOutSrc[1:0] modal parameter. If AUX_OUT is set to Lock, the AuxLockCfg global parameter is then used to control the output driver type and polarity of the LOCK signal (see section 6.3.2 on
page 22). If AUX_OUT is set to CLK_OUT, the phase of the PLL Clock Output signal on AUX_OUT may
differ from the CLK_OUT pin. The driver for the pin can be set to high-impedance using the M2 pin when
the M2Config[1:0] global parameter is set to either 001 or 010.
AuxOutSrc[1:0]
M2 pin with
M2Config[1:0] = 001, 010
Frequency Reference Clock
(CLK_IN)
PLL Clock Output
(PLLClkOut)
Auxiliary Output Pin
(AUX_OUT)
3:1 Mux
PLL Lock/Unlock Indication
(Lock)
AuxLockCfg
Figure 12. Auxiliary Output Selection
Referenced Control
Parameter Definition
AuxOutSrc[1:0]......................“Auxiliary Output Source Selection (AuxOutSrc[1:0])” on page 21
AuxOutDis .............................“M2 Configured as Output Disable” on page 18
AuxLockCfg...........................“AUX PLL Lock Output Configuration (AuxLockCfg)” section on page 22
M2Config[2:0]........................“M2 Pin Configuration (M2Config[2:0])” on page 22
5.7
5.7.1
Mode Pin Functionality
M1 and M0 Mode Pin Functionality
M[1:0] determine the functional mode of the device and select both the default User Defined Ratio and
the set of modal parameters. The modal parameters are RModSel[1:0], AuxOutSrc[1:0], and AutoRMod.
By modifying one or more of the modal parameters between the 4 sets, different functional configurations
can be achieved. However, global parameters are fixed and the same value will be applied to each functional configuration. Figure 14 on page 20 provides a summary of all parameters used by the device.
DS844PP1
17
CS2300-OTP
5.7.2
M2 Mode Pin Functionality
M2 usage is mapped to one of the optional special functions via the M2Config[2:0] global parameter. Depending on what M2 is mapped to, it will either act as an output enable/disable pin or override certain modal parameters. Figure 13 summarizes the available options and the following sections will describe each
option in more detail.
M2Config[2:0] global parameter
000
Disable CLK_OUT pin
001
Disable AUX_OUT pin
010
Disable CLK_OUT and AUX_OUT pins
011
RModSel[1:0] Modal Parameter Enable
100
Reserved
101
AutoRMod Modal Parameter Override
110
Reserved
111
Force AuxOutSel[1:0] = 10 (PLL Clock Out)
M2 pin
Figure 13. M2 Mapping Options
5.7.2.1
M2 Configured as Output Disable
If M2Config[2:0] is set to either ‘000’, ‘001’, or ‘010’, M2 becomes an output disable pin for one or
both output pins. If M2 is driven ‘low’, the corresponding output(s) will be enabled, if M2 is driven
‘high’, the corresponding output(s) will be disabled.
5.7.2.2
M2 Configured as R-Mod Enable
If M2Config[2:0] is set to ‘011’, M2 becomes the R-Mod enable pin. It should be noted that M2 is
the only way to enable R-Mod. Even though the RModSel[1:0] modal parameter can be set arbitrarily for each configuration set, it will not take effect unless enabled via M2. If M2 is driven ‘low’,
R-Mod will be disabled, if M2 is driven ‘high’ R-Mod will be enabled.
5.7.2.3
M2 Configured as Auto R-Mod Enable
If M2Config[2:0] is set to ‘101’, M2 becomes the Auto R-Mod enable pin and will override the AutoRMod modal parameter. If M2 is driven ‘low’, Auto R-Mod will be disabled, if M2 is driven ‘high’
Auto R-Mod will be enabled.
5.7.2.4
M2 Configured as AuxOutSrc Override
If M2Config[2:0] is set to ‘111’, M2 when driven ‘high’ will override the AuxOutSrc[1:0] modal parameter and force the AUX_OUT source to PLL Clock Output. When M2 is driven ‘low’, AUX_OUT
will function according to AuxOutSrc[1:0].
18
DS844PP1
CS2300-OTP
5.8
5.8.1
Clock Output Stability Considerations
Output Switching
The CS2300-OTP is designed such that re-configuration of the clock routing functions do not result in a
partial clock period on any of the active outputs (CLK_OUT and/or AUX_OUT). In particular, enabling or
disabling an output, and the automatic disabling of the output(s) during unlock will not cause a runt or partial clock period.
The following exceptions/limitations exist:
•
Enabling/disabling AUX_OUT when AuxOutSrc = 11 (unlock indicator).
•
Switching AuxOutSrc[1:0] to or from 01 (CLK_IN) and to or from 11 (unlock indicator)
(Transitions between AuxOutSrc[1:0] = [00,10] will not produce a glitch).
When any of these exceptions occur, a partial clock period on the output may result.
5.8.2
PLL Unlock Conditions
Certain changes to the clock inputs and mode pins can cause the PLL to lose lock which will affect the
presence of a clock signal on CLK_OUT. The following outlines which conditions cause the PLL to go unlocked:
•
Any change in the state of the M1 and M0 pins will cause the PLL to temporarily lose lock as the new
setting takes affect.
•
Changes made to the state of the M2 when the M2Config[2:0] global parameter is set to 011, 100, 101,
or 110 can cause the PLL to temporarily lose lock as the new setting takes affect.
•
Discontinuities on the Frequency Reference Clock, CLK_IN, except when the Clock Skipping feature
is enabled and the requirements of Clock Skipping are satisfied (see “CLK_IN Skipping Mode” on
page 10).
•
Gradual changes in CLK_IN frequency greater than ±30% from the starting frequency.
•
Step changes in CLK_IN frequency.
DS844PP1
19
CS2300-OTP
6. PARAMETER DESCRIPTIONS
As mentioned in Section 5.1 on page 10, there are two different kinds of parameter configuration sets, Modal and
Global. These configuration sets, shown in Figure 14, can be programmed in the field using the CDK2000 or preprogrammed at the factory. Please see “Programming Information” on page 25 for more details.
M[1:0] pins
Modal Configuration Set #0
Ratio 0
RModSel[1:0]
AuxOutSrc[1:0]
AutoRmod
00
RModSel[1:0]
AuxOutSrc[1:0]
AutoRmod
01
RModSel[1:0]
AuxOutSrc[1:0]
AutoRmod
10
RModSel[1:0]
AuxOutSrc[1:0]
AutoRmod
11
Ratio 1
Modal Configuration Set #2
Ratio 2
Modal Configuration Set #3
Ratio 3
Digital/PLL Core
Modal Configuration Set #1
Global Configuration Set
ClkSkipEn
AuxLockCfg
ClkOutUnl
LFRatioCfg
M2Config[2:0]
ClkIn_BW[2:0]
Figure 14. Parameter Configuration Sets
6.1
Modal Configuration Sets
There are four instances of each of these configuration parameters. Selection between the four stored sets
is made using the M[1:0] pins.
6.1.1
R-Mod Selection (RModSel[1:0])
Selects the R-Mod value, which is used as a factor in determining the PLL’s Fractional N.
RModSel[1:0]
R-Mod Selection
00
Right-shift R-value by 1 (÷ 2).
01
Right-shift R-value by 2 (÷ 4).
10
Right-shift R-value by 3 (÷ 8).
11
Right-shift R-value by 4 (÷ 16).
Application:
“Manual Ratio Modifier (R-Mod)” on page 14
Note: This parameter does not take affect unless M2 pin is high and the M2Config[2:0] global parameter is set to ‘011’.
20
DS844PP1
CS2300-OTP
6.1.2
Auxiliary Output Source Selection (AuxOutSrc[1:0])
Selects the source of the AUX_OUT signal.
AuxOutSrc[1:0]
Auxiliary Output Source
00
Reserved.
01
CLK_IN.
10
CLK_OUT.
11
PLL Lock Status Indicator.
Application:
“Auxiliary Output” on page 17
Note: When set to 11, the AuxLockCfg global parameter sets the polarity and driver type (“AUX PLL
Lock Output Configuration (AuxLockCfg)” on page 22).
6.1.3
Auto R-Modifier Enable (AutoRMod)
Controls the automatic ratio modifier function.
6.2
AutoRMod
Automatic R-Mod State
0
Disabled.
1
Enabled.
Application:
“Automatic Ratio Modifier (Auto R-Mod)” on page 14
Ratio 0 - 3
The four 32-bit User Defined Ratios are stored in the CS2300’s one time programmable memory. See “Output to Input Frequency Ratio Configuration” on page 13 and “Calculating the User Defined Ratio” on
page 24 for more details.
6.3
6.3.1
Global Configuration Parameters
Clock Skip Enable (ClkSkipEn)
This parameter enables clock skipping mode for the PLL and allows the PLL to maintain lock even when
the CLK_IN has missing pulses.
ClkSkipEn
PLL Clock Skipping Mode
0
Disabled.
1
Enabled.
Application:
“CLK_IN Skipping Mode” on page 10
Note:
DS844PP1
fCLK_IN must be < 80 kHz to use this feature.
21
CS2300-OTP
6.3.2
AUX PLL Lock Output Configuration (AuxLockCfg)
When the AUX_OUT pin is configured as a lock indicator (AuxOutSrc[1:0] modal parameter = ‘11’), this
global parameter configures the AUX_OUT driver to either push-pull or open drain. It also determines the
polarity of the lock signal. If AUX_OUT is configured as a clock output, the state of this parameter is disregarded.
AuxLockCfg
AUX_OUT Driver Configuration
0
Push-Pull, Active High (output ‘high’ for unlocked condition, ‘low’ for locked condition).
1
Open Drain, Active Low (output ‘low’ for unlocked condition, high-Z for locked condition).
Application:
“Auxiliary Output” on page 17
Note: AUX_OUT is an unlock indicator, signalling an error condition when the PLL is unlocked. Therefore, the pin polarity is defined relative to the unlock condition.
6.3.3
Enable PLL Clock Output on Unlock (ClkOutUnl)
Defines the state of the PLL output during the PLL unlock condition.
6.3.4
ClkOutUnl
Clock Output Enable Status
0
Clock outputs are driven ‘low’ when PLL is unlocked.
1
Clock outputs are always enabled (results in unpredictable output when PLL is unlocked).
Application:
“PLL Clock Output” on page 16
Low-Frequency Ratio Configuration (LFRatioCfg)
Determines how to interpret the currently indexed 32-bit User Defined Ratio .
6.3.5
LFRatioCfg
Ratio Bit Encoding Interpretation
0
20.12 - High Multiplier.
1
12.20 - High Accuracy.
Application:
“User Defined Ratio (RUD)” on page 13
M2 Pin Configuration (M2Config[2:0])
Controls which special function is mapped to the M2 pin.
22
M2Config[2:0]
M2 pin function
000
Disable CLK_OUT pin.
001
Disable AUX_OUT pin.
010
Disable CLK_OUT and AUX_OUT.
011
RModSel[1:0] Modal Parameter Enable.
100
Reserved.
101
AutoRMod Modal Parameter Override.
110
Reserved.
111
Force AuxOutSrc[1:0] = 10 (PLL Clock Out).
Application:
“M2 Mode Pin Functionality” on page 18
DS844PP1
CS2300-OTP
6.3.6
Clock Input Bandwidth (ClkIn_BW[2:0])
Sets the minimum loop bandwidth when locked to CLK_IN.
ClkIn_BW[2:0]
Minimum Loop Bandwidth
000
1 Hz
001
2 Hz
010
4 Hz
011
8 Hz
100
16 Hz
101
32 Hz
110
64 Hz
111
128 Hz
Application:
“Adjusting the Minimum Loop Bandwidth for CLK_IN” on page 12
DS844PP1
23
CS2300-OTP
7. CALCULATING THE USER DEFINED RATIO
Note:
The software for use with the evaluation kit has built in tools to aid in calculating and converting the User
Defined Ratio. This section is for those who would like to know more about how the User Defined Ratio is
calculated and stored.
Most calculators do not interpret the fixed point binary representation which the CS2300-OTP uses to define the
output to input clock ratio (see Section 5.4.1 on page 13); However, with a simple conversion we can use these tools
to generate a binary or hex value for Ratio0-3 to be stored in one time programmable memory. Please see “Programming Information” on page 25 for more details on programming.
7.1
High Resolution 12.20 Format
To calculate the User Defined Ratio (RUD) to store in the register(s), divide the desired output clock frequency by the given input clock (CLK_IN). Then multiply the desired ratio by the scaling factor of 220 to get the
scaled decimal representation; then use the decimal to binary/hex conversion function on a calculator and
write to the register. A few examples have been provided in Table 5.
Scaled Decimal
Representation =
(output clock/input clock) • 220
Hex Representation of
Binary RUD
12.288 MHz/10 MHz=1.2288
1288490
00 13 A9 2A
11.2896 MHz/44.1 kHz=256
268435456
10 00 00 00
Desired Output to Input Clock Ratio
(output clock/input clock)
Table 5. Example 12.20 R-Values
7.2
High Multiplication 20.12 Format
To calculate the User Defined Ratio (RUD) to store in the register(s), divide the desired output clock frequency by the given input clock (CLK_IN). Then multiply the desired ratio by the scaling factor of 212 to get the
scaled decimal representation; then use the decimal to binary/hex conversion function on a calculator and
write to the register. A few examples have been provided in Table 6.
Desired Output to Input Clock Ratio
(output clock/input clock)
Scaled Decimal
Representation =
(output clock/input clock) • 212
Hex Representation of
Binary RUD
12.288 MHz/60 Hz=204,800
838860800
32 00 00 00
11.2896 MHz/59.97 Hz =188254.127...
771088904
2D F5 E2 08
Table 6. Example 20.12 R-Values
24
DS844PP1
CS2300-OTP
8. PROGRAMMING INFORMATION
Field programming of the CS2300-OTP is achieved using the hardware and software tools included with the
CDK2000. The software tools can be downloaded from www.cirrus.com for evaluation prior to ordering a CDK. The
CDK2000 is designed with built-in features to ease the process of programming small quantities of devices for prototype and small production builds. In addition to its field programming capabilities, the CDK2000 can also be used
for the complete evaluation of programmed CS2300-OTP devices.
The CS2300-OTP can also be factory programmed for large quantity orders. When ordering factory programmed
devices, the CDK should first be used to program and evaluate the desired configuration. When evaluation is complete, the CS2000 Configuration Wizard is used to generate a file containing all device configuration information;
this file is conveyed to Cirrus Logic as a complete specification for the factory programming configuration. Please
contact your local Cirrus Logic sales representative for more information regarding factory programmed parts.
See the CDK2000 datasheet, available at www.cirrus.com, for detailed information on the use of the CDK2000 programming and evaluation tools.
Below is a form which represents the information required for programming a device (noted in gray). The “Parameter
Descriptions” section beginning on page 20 describes the functions of each parameter. This form may be used either for personal notation for device configuration or it can be filled out and given to a Cirrus representative in conjunction with the programming file from the CDK2000 as an additional check. The User Defined Ratio may be filled
out in decimal or it may be entered as hex as outlined in “Calculating the User Defined Ratio” on page 24. For all
other parameters mark a ‘0’ or ‘1’ below the parameter name.
OTP Modal and Global Configuration Parameters Form
Modal Configuration Set #0
Ratio 0 (dec)
Ratio 0 (hex) __ __ : __ __ : __ __ : __ __
RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0
AutoRMod
Modal Configuration Set #1
Ratio 0 (dec)
Ratio 0 (hex) __ __ : __ __ : __ __ : __ __
RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0
AutoRMod
Modal Configuration Set #2
Ratio 0 (dec)
Ratio 0 (hex) __ __ : __ __ : __ __ : __ __
RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0
AutoRMod
Modal Configuration Set #3
Ratio 0 (dec)
Ratio 0 (hex) __ __ : __ __ : __ __ : __ __
RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0
AutoRMod
Global Configuration Set
ClkSkipEn AuxLockCfg
ClkIn_BW2
DS844PP1
ClkIn_BW1
ClkOutUnl
LFRatioCfg
M2Cfg2
M2Cfg1
M2Cfg0
ClkIn_BW0
25
CS2300-OTP
9. PACKAGE DIMENSIONS
10L MSOP (3 mm BODY) PACKAGE DRAWING (Note 1)
N
D
E11
c
E
A2
A
∝
e
b
A1
SIDE VIEW
1 2 3
END VIEW
L
SEATING
PLANE
L1
TOP VIEW
DIM
MIN
INCHES
NOM
A
A1
A2
b
c
D
E
E1
e
L
L1
-0
0.0295
0.0059
0.0031
----0.0157
--
-----0.1181 BSC
0.1929 BSC
0.1181 BSC
0.0197 BSC
0.0236
0.0374 REF
MAX
0.0433
0.0059
0.0374
0.0118
0.0091
----0.0315
--
MIN
MILLIMETERS
NOM
NOTE
MAX
-0
0.75
0.15
0.08
----0.40
--
-----3.00 BSC
4.90 BSC
3.00 BSC
0.50 BSC
0.60
0.95 REF
1.10
0.15
0.95
0.30
0.23
----0.80
--
4, 5
2
3
Notes: 1. Reference document: JEDEC MO-187
2. D does not include mold flash or protrusions which is 0.15 mm max. per side.
3. E1 does not include inter-lead flash or protrusions which is 0.15 mm max per side.
4. Dimension b does not include a total allowable dambar protrusion of 0.08 mm max.
5. Exceptions to JEDEC dimension.
THERMAL CHARACTERISTICS
Parameter
Junction to Ambient Thermal Impedance
26
JEDEC 2-Layer
JEDEC 4-Layer
Symbol
Min
Typ
Max
Units
θJA
θJA
-
170
100
-
°C/W
°C/W
DS844PP1
CS2300-OTP
10.ORDERING INFORMATION
The CS2300-OTP is ordered as an un-programmed device. The CS2300-OTP can also be factory programmed for
large quantity orders. Please see “Programming Information” on page 25 for more details.
Product
Description
Package
Pb-Free
CS2300-OTP
Clocking Device
10L-MSOP
Yes
CS2300-OTP
Clocking Device
10L-MSOP
Yes
CDK2000
Evaluation Platform
-
Yes
Grade
Commercial
-
Temp Range Container
Order#
-10° to +70°C
Rail
CS2300P-CZZ
-10° to +70°C
Tape and
Reel
CS2300P-CZZR
-
-
CDK-2000-LCO
11.REVISION HISTORY
Release
A1
PP1
Changes
Initial Release
Updated “AC Electrical Characteristics” on page 7
Contacting Cirrus Logic Support
For all product questions and inquiries, contact a Cirrus Logic Sales Representative.
To find one nearest you, go to www.cirrus.com.
IMPORTANT NOTICE
“Preliminary” product information describes products that are in production, but for which full characterization data is not yet available.
Cirrus Logic, Inc. and its subsidiaries (“Cirrus”) believe that the information contained in this document is accurate and reliable. However, the information is subject
to change without notice and is provided “AS IS” without warranty of any kind (express or implied). Customers are advised to obtain the latest version of relevant
information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale
supplied at the time of order acknowledgment, including those pertaining to warranty, indemnification, and limitation of liability. No responsibility is assumed by Cirrus
for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third
parties. This document is the property of Cirrus and by furnishing this information, Cirrus grants no license, express or implied under any patents, mask work rights,
copyrights, trademarks, trade secrets or other intellectual property rights. Cirrus owns the copyrights associated with the information contained herein and gives consent for copies to be made of the information only for use within your organization with respect to Cirrus integrated circuits or other products of Cirrus. This consent
does not extend to other copying such as copying for general distribution, advertising or promotional purposes, or for creating any work for resale.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). CIRRUS PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE
IN PRODUCTS SURGICALLY IMPLANTED INTO THE BODY, AUTOMOTIVE SAFETY OR SECURITY DEVICES, LIFE SUPPORT PRODUCTS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF CIRRUS PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK AND CIRRUS DISCLAIMS AND MAKES NO WARRANTY, EXPRESS, STATUTORY OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR PARTICULAR PURPOSE, WITH REGARD TO ANY CIRRUS PRODUCT THAT IS USED IN SUCH A MANNER. IF THE CUSTOMER OR CUSTOMER’S CUSTOMER USES OR PERMITS THE USE OF CIRRUS PRODUCTS IN CRITICAL APPLICATIONS, CUSTOMER AGREES, BY SUCH USE, TO FULLY
INDEMNIFY CIRRUS, ITS OFFICERS, DIRECTORS, EMPLOYEES, DISTRIBUTORS AND OTHER AGENTS FROM ANY AND ALL LIABILITY, INCLUDING ATTORNEYS’ FEES AND COSTS, THAT MAY RESULT FROM OR ARISE IN CONNECTION WITH THESE USES.
Cirrus Logic, Cirrus, and the Cirrus Logic logo designs are trademarks of Cirrus Logic, Inc. All other brand and product names in this document may be trademarks
or service marks of their respective owners.
DS844PP1
27
CS2300-OTP
28
DS844PP1