CPC1218 4-Pin SIP OptoMOS® Relay Blocking Voltage Load Current Max RON Input Voltage to operate CPC1218 60 600 1.1 5-12 Description Units VP mA Ω V Features • • • • • • • • • • • 100% Solid State Voltage-controlled operation Matches popular reed relay pin-out Designed for use in security systems complying with EN50130-4 Small 4-Pin SIP Package TTL/CMOS Compatible input Arc-Free With No Snubbing Circuits 2500Vrms Input/Output Isolation No EMI/RFI Generation Immune to radiated EM fields Auto Pick & Place, Wave Solderable The CPC1218 is a miniature voltage-controlled 1-Form-A Solid State Relay in a 4-pin Single In-line Package (SIP) that employs optically coupled MOSFET technology to provide 2500Vrms of input to output isolation. The super efficient MOSFET switches and photovoltaic die use Clare’s patented OptoMOS® architecture. The optically-coupled output is controlled by the input's highly efficient GaAlAs infrared LED and a built-in series resistor to provide input voltage-controlled operation. The CPC1218 features a pin-out that matches many popular reed relays and is thus a "drop-in" solid state replacement. Because the input is solid state there is no need for snubbers or "catch" diodes to suppress the inductive fly back transient voltage normally associated with EMR coils. Approvals • UL Recognized Component: File # E76270 • EN/IEC 60950 Compliant • CSA Certified Component: Certificate # 1172007 Applications • Security • Passive Infrared Detectors (PIR) • Data Signalling • Sensor Circuitry • Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Energy Meters • Medical Equipment—Patient/Equipment Isolation • Aerospace • Industrial Controls Ordering Information Part # CPC1218Y Description 4-Pin SIP (25/tube) Pin Configuration CPC1218 Pinout 1 2 + 3 – 4 Switching Characteristics of Normally Open (Form A) Devices CONTROL ILOAD + 90% 10%+ TON Pb RoHS 2002/95/EC DS-CPC1218-R04 TOFF e3 www.clare.com 1 CPC1218 Absolute Maximum Ratings (@ 25˚ C) Parameter Blocking Voltage Reverse Input Voltage Input Control Voltage Input Power Dissipation Total Power Dissipation 1 Isolation Voltage, Input to Output Operational Temperature Storage Temperature 1 Ratings 60 5 15 225 800 2500 -40 to +85 -40 to +125 Units VP V V mW mW Vrms ºC ºC Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Derate Linearly 6.67 mw / ºC Electrical Characteristics Parameter Output Characteristics @ 25°C Load Current, Continuous 1 Peak Load Current On-Resistance 2 Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Input Characteristics @ 25°C Input Control Voltage (must operate) Off Voltage (must be off) Reverse Input Current Input Resistor Common Characteristics @ 25°C Capacitance Input to Output 1 2 2 Conditions Symbol Min Typ Max Units VIN=5V t=10ms IL=600mA VL=60V IL ILPK RON ILEAK - - 600 1 1.1 1 mA A Ω VIN=5V, VL=10V VIN=5V, VL=10V 50V; f=1MHz TON TOFF COUT - 25 5 5 - ms ms pF IL=600mA VR=5V - VOP VOFF IR - 1 900 1000 3.75 10 1100 V V μA Ω - - - 1 - pF μA Load current derates linearly from 600mA @ 25oC to 480mA @80oC. Measurement taken within 1 second of on time. www.clare.com R04 CPC1218 PERFORMANCE DATA* CPC1218 Typical On-Resistance Distribution (TA=25ºC, IL=100mA, VIN=5V) 35 35 20 15 10 20 15 10 0.58 0.60 0.62 0.64 0.66 63.5 64.0 64.5 65.0 65.5 66.0 1.5 1.55 1.6 1.65 1.7 1.75 1.8 Input Voltage (V) CPC1218 Typical VOFF for Switch Dropout (TA=25ºC, IL=100mA) CPC1218 Typical Turn-On Time (TA=25ºC, IL=100mA, VIN=5V) CPC1218 Typical Turn-Off Time (TA=25ºC, IL=100mA, VIN=5V) 25 5 25 20 Device Count (N) Device Count (N) 10 15 10 5 0 0 CPC1218 Typical Maximum Load Current vs. Temperature CPC1218 Typical Leakage vs. Temperature (Measured Across Pins 1 & 4) (VL=Max Rated) 1.6 1.65 1.7 1.75 0.41 1.8 0.016 0.75 0.014 0.70 0.012 0.65 0.60 0.55 VIN =10V 0.50 Leakage (μA) 0.80 0.43 0.51 VIN =5V 0.40 -20 0 20 40 60 80 Temperature (ºC) 100 0.008 0.006 Turn-Off (ms) VIN = 5V VIN = 10V 0 20 40 60 Temperature (ºC) 80 100 0 20 40 60 80 100 VIN = 10V VIN = 5V -40 0.24 0.25 68 66 64 62 60 58 -20 -40 CPC1218 Typical Turn-Off vs. Temperature (IL=100mA) 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.21 0.22 0.23 Turn-Off (ms) 70 -20 0 Temperature (ºC) CPC1218 Typical Turn-On vs. Temperature (IL=100mA) -20 0.20 72 0.010 0 -40 120 5 CPC1218 Typical Blocking Voltage vs. Temperature 0.002 0.35 10 0.19 0.004 0.45 15 0.53 Blocking Voltage (VP) Input Voltage (V) 1.55 20 0 0.45 0.47 0.49 Turn-On (ms) 1.5 -40 5 Blocking Voltage (VP) 15 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 10 On-Resistance (Ω) 20 -40 15 66.5 -20 0 20 40 60 Temperature (ºC) 80 100 Turn-On (ms) 25 0.56 20 0 0 0.54 Device Count (N) 25 5 0 Load Current (A) Device Count (N) 25 5 Turn-On (ms) 25 30 Device Count (N) Device Count (N) 30 CPC1218 Typical Input Voltage for Switch Operation (TA=25ºC, IL=100mA) CPC1218 Typical Blocking Voltage Distribution (TA=25ºC) 20 40 60 Temperature (ºC) 80 100 CPC1218 Typical Turn-On vs. Input Voltage (IL=100mA) 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0 5 10 Input Voltage (V) 15 20 *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R04 www.clare.com 3 CPC1218 PERFORMANCE DATA* 0.7 1.0 0.4 0.3 0.2 6 8 10 12 14 Input Voltage (V) 16 18 20 600 Load Current (mA) 1.40 1.35 1.30 1.25 1.15 -40 -20 0 20 40 60 Temperature (ºC) 80 100 1.30 1.25 1.15 -20 0 20 40 60 Temperature (ºC) 80 100 -40 CPC1218 Typical Load Current vs. Load Voltage (TA=25ºC, VIN=5V) 200 0 -200 -600 -0.3 -0.2 -0.1 0 0.1 Load Voltage (V) 0.2 0.3 -20 0 60 20 40 Temperature (ºC) 80 100 CPC1218 Energy Rating Curve 400 -400 1.20 1.35 1.20 -40 CPC1218 Typical Input Voltage for Switch Dropout vs. Temperature (IL=100mA) 1.45 Input Voltage (V) 0.5 0.3 4 VIN = 10V 0.6 0.4 2 Steady State 0.7 0 0 1.40 0.8 0.1 1.45 Load Current (A) 0.5 CPC1218 Typical Input Voltage for Switch Operation vs. Temperature (IL=100mA) VIN = 5V 0.9 On-Resistance (Ω) Turn-Off (ms) 0.6 CPC1218 Typical On-Resistance vs. Temperature (IL=Max Rated @ Temperature) Input Voltage (V) CPC1218 Typical Turn-Off vs. Input Voltage (IL=100mA) 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 10μs 100μs 1ms 10ms 100ms 1s 10s 100s Time *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.clare.com R04 Manufacturing Information Soldering For proper assembly, the component must be processed in accordance with the current revision of IPC/JEDEC standard J-STD-020. Failure to follow the recommended guidelines may cause permanent damage to the device resulting in impaired performance and/or a reduced lifetime expectancy. Washing Clare does not recommend ultrasonic cleaning or the use of chlorinated solvents. Pb e3 RoHS 2002/95/EC MECHANICAL DIMENSIONS 4-Pin SIP 3.302 ± 0.051 (0.130 ± 0.002) 19.202 ± 0.381 (0.756 ± 0.015) 6.401 ± 0.127 (0.252 ± 0.005) 2.642 ± 0.127 TYP (0.104 ± 0.005 TYP) 5.944 ± 0.127 TYP (0.234 ± 0.005 TYP) PIN 1 0.457 ± 0.076 TYP (0.018 ± 0.003 TYP) 5.080 ± 0127 (0.200 ± 0.005) 3.251 ± 0.102 (0.128 ± 0.004) 5.080 ± 0127 (0.200 ± 0.005) NOTES: 1. Leadframe thickness does not include plating. (1000 microinches maximum) 2. Pin location tolerances are non-accumulative. 0.254 ± 0.013 (0.010 ± 0.0005) Dimensions: mm (inches) For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-CPC1218-R04 ©Copyright 2008, Clare, Inc. OptoMOS® is a registered trademark of Clare, Inc. All rights reserved. Printed in USA. 7/16/08 5