CPC1219 4-Pin SIP OptoMOS® Relay Blocking Voltage Load Current Max RON Input Voltage to operate CPC1219Y 60 200 16 5-12 Description Units VP mA Ω V Features • 100% Solid State • Voltage-controlled operation • Designed for use in security systems complying with EN50130-4 • Small 4-Pin SIP Package • Arc-Free With No Snubbing Circuits • 2500Vrms Input/Output Isolation • No EMI/RFI Generation • Immune to radiated EM fields • Auto Pick & Place, Wave Solderable The CPC1219 is a voltage-controlled, single-pole, normally closed (1-Form-B) optically coupled solid state relay configuration in a 4-pin Single In-line Package (SIP). Clare's patented OptoMOS architecture makes available the optically coupled technology necessary to activate the output's efficient MOSFET switches while providing a 2500Vrms input-to-output isolation barrier. Control of the isolated output is accomplished by means of a highly effective GaAlAs infrared LED at the input. An internal resistor in series with the LED enables the input voltage-controlled operation. Because the input is solid state there is no need for snubbers or "catch" diodes to suppress the inductive flyback transient voltage normally associated with EMR coils. Approvals • UL and CSA Pending Ordering Information Applications • Security • Passive Infrared Detectors (PIR) • Data Signalling • Sensor Circuitry • Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Energy Meters • Medical Equipment—Patient/Equipment Isolation • Aerospace • Industrial Controls Part # CPC1219Y Description 4-Pin SIP (25/tube) Pin Configuration CPC1219 Pinout 1 2 3 4 Load IN + IN - Load Switching Characteristics of Normally Closed (Form B) Devices CONTROL + ILOAD TOFF Pb RoHS 2002/95/EC DS-CPC1219-R04 90% +10% TON e3 www.clare.com 1 CPC1219 Absolute Maximum Ratings (@ 25˚ C) Parameter Blocking Voltage Reverse Input Voltage Input Control Voltage Input Power Dissipation Total Power Dissipation 1 Isolation Voltage Input to Output Operational Temperature Storage Temperature 1 Ratings 60 5 15 225 800 2500 -40 to +85 -40 to +125 Units VP V V mW mW Vrms °C °C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Derate Linearly 6.67 mW / ºC Electrical Characteristics Parameter Output Characteristics @ 25°C Load Current, Continuous 1 Peak Load Current On-Resistance 2 Off-State Leakage Current Switching Speeds Turn-On (Output Closed) Turn-Off (Output Open) Output Capacitance Input Characteristics @ 25°C Input Control Voltage Output Open Output Closed Recommended Operating Range Reverse Input Current Input Resistor Common Characteristics @ 25°C Capacitance Input to Output 1 2 2 Conditions Symbol Min Typ Max Units t≤10ms IL=200mA VL=60V, VIN=5V IL ILPK RON ILEAK - - 200 400 16 1 mA mA Ω VIN = 5V, VL = 10V tON tOFF - - 5 5 ms ms VIN=5V, VL=50V, f=1MHz COUT - 25 - pF - - 3.75 V IL = 200mA VIN VIN = -5V - IR - 1 5 900 1000 12 10 1100 V V μA Ω - - - 1 - pF μA Load current derates linearly from 200mA @ 25oC to 125mA @80oC. Measurement taken within 1 second of on time. www.clare.com R04 CPC1219 PERFORMANCE DATA* Typical On-Resistance Distribution (TA=25ºC, IL=100mA, VIN=0V) 35 35 25 20 15 10 Device Count (N) Device Count (N) 25 20 15 10 5 5 4.9 5.0 5.1 5.2 5.3 5.4 5.5 89 90 On-resistance (Ω) Typical VOFF for Switch Dropout (TA=25ºC, IL=100mA) 15 10 5 1.23 1.24 1.25 1.26 Input Voltage (V) 1.27 10 5 Typical Maximum Load Current vs. Temperature 0.16 75 Typical Leakage vs. Temperature (Measured Across Pins 1 & 4) (VIN=5V, VL=60V) 0 0 20 40 60 80 Temperature (ºC) 100 120 -40 Typical Turn-On vs. Temperature (IL=100mA) VIN = 5V -20 0 20 40 60 Temperature (ºC) 80 100 1.27 1.28 15 10 5 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 -40 -20 0 20 40 60 Temperature (ºC) 80 20 40 60 Temperature (ºC) 0.76 0.83 102 100 98 96 94 92 90 -40 100 -20 0 20 40 60 80 100 Temperature (ºC) VIN = 5V 0 0.55 0.62 0.69 Turn-Off (ms) Typical Blocking Voltage vs. Temperature (VIN=5V) Typical Turn-Off vs. Temperature (IL=100mA) -20 0.48 104 0.06 25 0 1.26 20 0.41 0.08 0.02 -20 1.25 Typical Turn-Off Time (TA=25ºC, IL=100mA, VIN=5V) 0.70 0.10 0.04 -40 0.63 0.12 50 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0.42 0.49 0.56 Turn-On (ms) Blocking Voltage (VP) 100 Leakage (μA) 125 Turn-Off (ms) Load Current (mA) VIN = 0V 150 -40 0.35 0.14 175 1.24 0 0.28 200 1.23 25 15 1.28 225 5 1.22 0 1.22 10 Input Voltage (V) 20 0 15 95 Device Count (N) 20 91 92 93 94 Blocking Voltage (VP) Typical Turn-On Time (TA=25ºC, IL=100mA, VIN=5V) 25 Device Count (N) Device Count (N) 25 20 0 0 0 Turn-On (ms) Device Count (N) 25 30 30 Turn-On (ms) Typical Input Voltage for Switch Operation (TA=25ºC, IL=100mA) Typical Blocking Voltage Distribution (TA=25ºC, VIN=5V) 80 100 Typical Turn-On vs. Input Voltage (TA=25ºC, IL=100mA) 0.54 0.53 0.52 0.51 0.50 0.49 0.48 0.47 0.46 0.45 0.44 0 5 10 15 20 Input Voltage (V) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R04 www.clare.com 3 CPC1219 PERFORMANCE DATA* Typical On-Resistance vs. Temperature (IL=Max Rated @ Temperature) 2.1 On-Resistance (Ω) 1.5 1.2 0.9 0.6 1.30 7 Steady State 6 0.3 0 3 2 4 6 8 10 12 14 Input Voltage (V) 16 18 1.30 -20 0 20 40 60 Temperature (ºC) 80 100 Load Current (mA) 1.24 1.22 1.20 Typical Load Current vs. Load Voltage (TA=25ºC, VIN=0V) 100 50 0 -50 -100 -150 1.18 -40 -20 0 20 40 60 Temperature (ºC) 80 100 1.26 1.24 -40 -200 -1.0 -0.75 -0.50 -0.25 0 0.25 0.50 0.75 Load Voltage (V) 1.0 -20 0 60 20 40 Temperature (ºC) 80 100 Energy Rating Curve 150 1.26 1.28 1.20 200 1.28 Typical Input Voltage for Switch Operation vs. Temperature (IL=100mA) 1.22 -40 20 Typical Input Voltage for Switch Dropout vs. Temperature (IL=100mA) VIN = 0V 5 4 0 Input Voltage (V) 1.32 8 Load Current (mA) Turn-Off (ms) 1.8 9 Input Voltage (V) Typical Turn-Off vs. Input Voltage (TA=25ºC, IL=100mA) 500 450 400 350 300 250 200 150 100 50 0 10μs 100μs 1ms 10ms 100ms Time 1s 10s 100s *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.clare.com R04 MANUFACTURING INFORMATION Soldering For proper assembly, the component must be processed in accordance with the current revision of IPC/JEDEC standard J-STD-020. Failure to follow the recommended guidelines may cause permanent damage to the device resulting in impaired performance and/or a reduced lifetime expectancy. Washing Clare does not recommend ultrasonic cleaning or the use of chlorinated solvents. Pb RoHS 2002/95/EC e3 MECHANICAL DIMENSIONS 4-Pin SIP 3.302 ± 0.051 (0.130 ± 0.002) 19.202 ± 0.381 (0.756 ± 0.015) 6.401 ± 0.127 (0.252 ± 0.005) 2.642 ± 0.127 TYP (0.104 ± 0.005 TYP) 5.944 ± 0.127 TYP (0.234 ± 0.005 TYP) PIN 1 0.457 ± 0.076 TYP (0.018 ± 0.003 TYP) 5.080 ± 0127 (0.200 ± 0.005) 3.251 ± 0.102 (0.128 ± 0.004) 5.080 ± 0127 (0.200 ± 0.005) NOTES: 1. Leadframe thickness does not include plating. (1000 microinches maximum) 2. Pin location tolerances are non-accumulative. 0.254 ± 0.013 (0.010 ± 0.0005) Dimensions: mm (inches) For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-CPC1219-R04 ©Copyright 2008, Clare, Inc. OptoMOS® is a registered trademark of Clare, Inc. All rights reserved. Printed in USA. 8/27/08 5