CliQ Din Rail Power Supply 12V 100W 1 Phase DRP012V100W1AA DRP012V100W1AA 100Watts Total Power: 100Watts Input Voltage: 85-264Vac # of Output: Single Model number DRP012V100W1AA EOE11010160 Special Features Output power Output voltage range Output current Residual ripple/peak switching (20MHz) (@ nominal values) Mains buffering at nominal load (typ.) Line regulation Load regulation 100W 11-14V 8.33A (100W max.) < 100mV • Reference no. OUTPUT (DC) > 22ms @ 115Vac, > 110ms @ 230Vac < 0.5% typ. (@ 85 - 264Vac input, 100% load) < 1% Typical (with rated input, 0 to 100% load) INPUT (AC) Input voltage range Input frequency Nominal current 85 - 264Vac (DC input range 120 - 375Vdc) 47 - 63Hz 2.90A Max ( 2.5A @ 115Vac & 1.5A @ 230Vac) Efficiency Power factor Inrush current limitation I²t (+25°C) typ. Leakage current Min 86% @ 115Vac & Min 87.5% @ 230Vac Conform to EN61000-3-2 STD < 100A @ 115VAC & No Damage @ 230VAC < 1mA • • • • • • • Ease of multiple wire connection Compact design for easy handling Overload protection Thermal protection Power boost 150% for 3secs Expected life time: 10 years Redundancy: Yes (with external ORing diode) RoHS compliant MECHANICAL DESIGN Case cover Aluminium (Al5052) Dimensions (L x W x H) 121mm x 50mm x 118.2mm Unit weight / box 0.636kg MTBF > 300,000 hrs Noise Cooling Sound pressure level (SPL) < 40dBA Convection Input terminal Output terminal M4 x 3 M4 x 2 QPA-2pcs Mounting rail Standard TS35 mounting rail Shock proof Vibration Protection structure IEC60068-2-27 IEC60068-2-6 EN60950 meet IPX0 3 PET E315355 R CliQ Din Rail Power Supply 12V 100W 1 Phase DRP012V100W1AA MECHANICAL DRAWING Delta Electronics (Thailand) Public Company Limited 909 Moo 4, E.P.Z., Bangpoo Industrial Estate, Tambon Prakasa, Amphur Muang Samutprakarn, Samutprakarn 10280, Thailand Tel: +662 709 2800 Fax: +662 709 2827 E-mail: [email protected] www.deltaenergysystems.com SAFETY / ENVIRONMENTAL EMC / Emissions Immunity Safety standard Voltage dips Galvanic isolation EN61000-3-2, 3 : 1995/A1 : 2001/A2 : 2005, EN55022 : 2006 Class B, EN55011 : 1998/A2 : 2002 Class B, EN6100-6-1 (IEC61000-4-2, 3, 4, 5, 6, 8,11) EN61000-6-2, EN55024, EN61000-4-2, IEC61000-4-3, 4, 5, 6, 8, 11 UL Listed for UL508 & CSA 22.2 no.107.1-01, UL Recognized for UL60950-1 & CSA 22.2 no.60950-1, UL60950-1 and CSA 22.2 no.107.1-01, TUV Bavart Mark to EN60950-1, EN50178 : 1998, IEC60204-1 : 1998 & IEC62103 : 2003, CB cert from TUV to IEC60950-1, CE (EMC and Low Voltage directive) , CCSAUS to CSA 22.2 no.60950-1 Conforms to EN61000-4-11 Input to output: 4KVac; Input to ground: 1.5KVac; Output to ground: 1.5KVac Operating ambient temperature Storage temperature -20°C ~ 75°C * -25°C ~ 85°C Operating humidity Note (*) < 95% Operating amb. > 50°C derate power by 2.5% /°C