CliQ Din Rail Power Supply 24V 120W 1 Phase DRP024V120W1AA DRP024V120W1AA 120Watts Total Power: 120Watts Input Voltage: 85-264Vac # of Output: Single Model number Reference no. OUTPUT (DC) DRP024V120W1AA EOE12010002 Output power Output voltage range 120W 22 - 28V Output current 5A Residual ripple/peak switching (20MHz) < 50mV / < 240mVpp (@ nominal values) Mains buffering at nominal load (typ.) > 35ms @ 115Vac, > 70ms @ 230Vac Line regulation < 0.5% typ. (@ 85 - 264Vac input, 100% load) Load regulation < 1% typ. (with rated input, 0 - 100% load) INPUT (AC) Input voltage range 85 - 264Vac (DC input range 120 - 375Vdc) Input frequency 47 - 63Hz Nominal current 1.4A @ 115Vac, 0.8A @ 230Vac Efficiency Power factor > 84% typ. Conform to EN61000-3-2 STD Inrush current limitation I²t (+25°C) typ. < 80A @ 115Vac Leakage current < 1mA Special Features - Ease of wire connection to terminals - Compact design for easy handling - Overload protection - Overvoltage protection - Thermal protection - Power boost 150% for 3 seconds - Expected life time : 10 years - Shock proof IEC60068-2-27 - Vibration IEC60068-2-6 - Cooling : Convection - Operating Humidity : < 95% - Redundancy : Yes (with external ORing diode) - RoHS compliant MECHANICAL DESIGN Case cover Aluminium (AI5052) Dimensions (L x W x H) 121mm x 50mm x 118.2mm Unit weight / box 0.540kg MTBF > 800,000 hrs Noise Cooling Sound pressure level (SPL) < 40dBA Convection Input terminal M4 x 3 Output terminal M4 x 2 (2 pcs.) Mounting rail Standard TS35 mounting rail Shock proof Vibration IEC60068-2-27 IEC60068-2-6 Protection structure EN60950 meet IPX0 3 PET E315355 R L3M1 CliQ Din Rail Power Supply 24V 120W 1 Phase DRP024V120W1AA MECHANICAL DRAWING Delta Electronics (Thailand) Public Company Limited 909 Moo 4, E.P.Z., Bangpoo Industrial Estate, Tambon Prakasa, Amphur Muang Samutprakarn, Samutprakarn 10280, Thailand Tel: +662 709 2800 Fax: +662 709 2827 E-mail: [email protected] www.deltaenergysystems.com SAFETY / ENVIRONMENTAL EMC / Emissions Immunity Safety standard Voltage dips Galvanic isolation Operating ambient temperature Storage temperature Operating humidity Note (*) Class B / EN55022, CISPR22, Class B; FCC Tilte 47; EN61204-3 (Class B on AC & Class A on DC side), EN55022:2006 Class B, EN61000-3-2:2006, EN61000-3-3:1995/ A1:2001/A2:2005 EN55024:1998/A1:2001/A2:2003 UL508, CSA C22.2 No.107.1-01,UL60950-1, CSA C22.2 No.60950-1, IEC60950-1, EN60950-1, EN50178, IEC62103 and IEC60204-1 Conform to EN61000-4-11 Input to output: 4KVac Input to ground: 1.5KVac Output to ground: 1.5KVac -20°C ~ 75°C * -25°C ~ 85°C < 95% * Operating amb. > 50°C derate power by 2.5% / °C