EMERSON-NETWORKPOWER AUG05K48

Embedded Power for
Business-Critical Continuity
Rev. 09.20.05
AUG Series
1 of 2
AUG Series
15 Watts
Total Power:
10 Watts
Input Voltage: 36V - 75V
# of Outputs: Single
Electrical Specifications
Input
Input range
Special Features
• Ultra Low Profile - 4.3mm
• Efficiency - 89% @ 5V
• -40°C to +85°C Operating
temperature(Ambient)
• Open Frame SMT
• Low output ripple and noise
• Regulation to zero load
• CISPR22, Class A for Conduct
and Radiated EMI
• Parallel Application
• Pb-free reflow compatible
and ROHS compliant
Efficiency
36 - 60 VDC
60 - 75VDC (forced air 1.0m/s)
89% @ 5Vo
Output
Line / Load Regulation
Noise / Ripple
OVP
OCP
LVP
+5%, -3%
50mV p-p
120% of Vonom (latch-up)
3.1A for 5V
4.65A for 1.8V - 3.3V
5.4A for 1.2V
90% of Vonom (latch-up)
Isolation
1500VDC
Control
Enable
ON: RC pin connected to -Vin or open
OFF: RC pin connected to +Vin
Environmental Specifications
Ambient Operating temperature
Storage temperature
Safety
UL
CE
60950
CE Mark
-40°C to +85°C (forced air 0.2m/s)
-45°C to +90°C
Embedded Power for
Business-Critical Continuity
Astec Power
Ordering Information
Input Voltage
48V
48V
48V
48V
48V
Output Voltage
1.2V @ 5.2A
1.8V @ 4.5A
2.5V @ 4.5A
3.3V @ 4.5A
5.0V @ 3A
Efficiency
82% (Typ)
84% (Typ)
86% (Typ)
88% (Typ)
89% (Typ)
Model Number
AUG05K48
AUG04Y48
AUG04G48
AUG04F48
AUG03A48
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Technical Support: +1 888 41 ASTEC
or +1 407 241 2752
4.17+/-0.5
Pin Assignment
P=2.54+/-0.2
Tolerance is not accumulated.
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
US
Marking of No.1 pin
20
19
P P P P
10.3+/-0.2
17
16
Units 2111-2116, Level 21
Tower 1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: +852 2437 9662
Facsimile: +852 2402 4426
15
P P P P
A BCD E F
14
13
12
11
10
For global contact, visit:
(4.17)
(4P)
6
18
OUTPUT=M . N V O P Q A
AUG0 K L 48
31.2+/-0.5
4
5
INPUT=36-60VDC
C
P
1
2
3
www.astecpower.com
[email protected]
37.3+/-0.5
4.3max
While every precaution has been taken to ensure
accuracy and completeness in this literature, Astec
Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
1.5+/-0.2
Coplanarity Max0.1
0.25+/-0.1
39.9+/-0.6
0.55
Printed in US A
0to10deg
1.3+/-0.3
+0.1
-0.15
Enlarged pin shape
Pin Assignments
Pin No
Symbol
Function
Rev. 09.20.05
AUG Series
2 of 2
Pin No
Symbol
Function
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
1, 10, 11, 20 NC
2
+Vout
Mechanical supplemental contact pins 12
+Output
13
ALM
RC
Alarm output
Remote on/off control
Connectivity
3
+Vout
+Output
14
PO
Parallel operation
4
+Vout
+Output
15
-
-
DC Power
5
-Vout
-Output
16
+Vin
+Input
Embedded Power
6
-Vout
-Output
17
+Vin
+Input
18
-Vin
-Input
Inbound Power
19
-Vin
-Input
Note: Astec reserves the right to make changes to the information contained herein without notice and assumes no liability of its use
and application.
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2005 Emerson Electric Co.