20 Amps
Total Power:
Input Voltages:
No. of Outputs:
240W
48
1
ALQ/AEQ20B48
Electrical Specs
Input
Input Range
36 to 75 VDC
Input Surge
100V /100ms
Efficiency
93% (Typical)
Output
Line Regulation
± 0.1% (Typical)
Load Regulation
± 0.1% (Typical)
Noise/Ripple1
60mV (Typical)
Transient Response
5% deviation
(50% to 75% step load)
< 250µs settling time
Special Features
Over Current protection 130% IO (autorecovery)
• Quarter brick industry standard outline
• Baseplate or openframe low profile construction
• Industry Standard features : Input UVLO with
hysteresis, Enable, OVP, OCP, OTP, output
Voltage Trim, Differential Remote Sense
• Fixed switching frequency for EMI predictability
• Prebias startup capable
• RoHS compliant
• Meets basic insulation
Over Voltage protection 120% VO (autorecovery)
Over Temperature
Protection
115ºC average PCB temperature
(autorecovery)
Switching Frequency
150kHz
Isolation Voltage
2250 Vdc
Control
Enable On/Off
Positive or Negative Logic Options
TTL Compatible
Environmental
Ambient air operating temperature range:
-40°C to +85°C
Storage temperature: -40°C to +125°C
MTBF: > 1 million hours
Safety
UL, cUL 60950 (Pending)
TUV EN60950 (Pending)
1
North America (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
ALQ / AEQ20B48
Ordering Information
Input
Voltage
Output
Voltage
Output
Current
Efficiency2
Model Number
36V to 75V
36V to 75V
12V
12V
20A
20A
93% Typ
93% Typ
ALQ20B48(N)-(6)
AEQ20B48(N)-(6)
OPTIONS
(N) : =
(6) : =
ALQ : =
AEQ: =
designates Negatve Logic Enable (default is Positive Enable with no suffix “N” required)
denotes 3.7mm Pin length (default is 5mm)
openframe construction
baseplate construction
Pin Assignments
1.
2.
3.
4.
5.
6.
7.
8.
MECHANICAL OUTLINE
OPENFRAME
+ Vin
Enable On/Off
- VIN
- VO
- Sense
Trim
+ Sense
+VO
PIN Length (inch [mm])
Std : 0.197 [5.0]
“-6” : 0.146 [3.7]
Notes:
1. Measured at 20MHz bandwidth with external 10 uF
tant. capacitor in parallel with 1 uF ceramic capacitor
across +VO and -VO, TA = 25 °C.
2. Efficiency measurements taken at nominal line, VIN =
48V, IO = 100% load, TA = 25 °C.
3. All specifications are considered typical values unless
otherwise noted and are subject to change without
notice.
4. 1 year warranty.
BASEPLATE
5. Consult factory for further product technical details.
www.astecpower.com
Astec Industry Standard
Preliminary Data Sheet. Astec reserves the right to make
changes to the information contained herein without notice
and assumes no liability as a result of its use or application.
(REV A1: JANUARY 9, 2006)
2