Embedded Power for Business-Critical Continuity Rev.03.08.07 bxb75s 1 of 4 BXB75 Series Single output Total Power: 50 - 75W Input Voltage: 36 - 75VDC # of Outputs: Single Special Features • Industry standard footprint MTBF >1.4 million hours (Bellcore 332) • Input voltage to ETS300-132-2 • Adjustable output voltage • No minimum load required • Separate case ground pin • 2:1 input range for battery powered applications • Undervoltage lockout (UVLO) • UL, VDE and CSA safety approvals • Available RoHS compliant • 2 year warranty Safety VDE0805/EN60950/IEC950 File No. 10401-3336-0205 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C The BXB75 Series are high power density dc-dc converters packaged in the industry standard footprint (2.40 x 2.28 x 0.50 inches) to give designers optimum choices when specifying for both new and replacement designs. Suitable for a wide range of applications in nearly any industry, the BXB75 was particularly designed with communication and distributed power applications in mind. Using Bellcore 332, the MTBF is greater than 1,400,000 hours. Aluminum baseplate technology with four threaded M3 inserts makes heatsink attachment and optimum thermal management easy. The BXB75 series is approved to IEC950 by UL, CSA and VDE. Embedded Power for Business-Critical Continuity Rev.03.08.07 bxb75s 2 of 4 Specifications All specifications are typical at nominal input, full load at 25°C unless otherwise stated. OUTPUT SPECIFICATIONS INPUT SPECIFICATIONS (continued) Voltage adjustability 60% to 110% Set point accuracy ±1.0% Undervoltage lockout 48 Vin: power up 48 Vin: power down 34 V 32.5 V Power up Remote ON/OFF 20 ms 20 ms Line regulation Low line to high line ±0.05% Start-up time (See Note 8) Load regulation Full load to min. load ±0.10% EMC CHARACTERISTICS Minimum load Overshoot 0% At turn-on and turn-off Undershoot Ripple and noise (5 Hz to 20 MHz) (See Note 1) None None 3.3 V and 5 V 75 mV pk-pk, 20 mV rms 100 mV pk-pk, 30 mV rms 12 V Temperature coefficient ±0.01%/°C Transient response (See Note 2) ±2.0% max. deviation 170 μs recovery to within ±1.0% Remote sense 0.5 Vdc transmission line drop compensation Bellcore 1089 FCC part 15 EN55022, CISPR22 Efficiency See table Isolation voltage Input/case Input/output Output/case Switching frequency Fixed Approvals and standards (See Note 5) 1500 Vdc 1500 Vdc 1500 Vdc 500 kHz typ. VDE0805, EN60950, IEC950 UL1950, CSA C22.2 No. 950 Case material Aluminum baseplate with plastic case UL94V-0 Weight Input voltage range 48 Vin nominal Input current No load Remote OFF Input current (max.) (See Note 4) 36-75 Vdc MTBF 100 mA max. 20 mA max. 3.5 A max. @ Io max. and Vin = 0-75 V (See Note 6) 5 mA pk-pk Active low remote ON/OFF (See Note 7) Logic compatibility ON OFF Open collector ref to -input 1.2 Vdc max. Open circuit Level A Level A Level A GENERAL SPECIFICATIONS Material flammability INPUT SPECIFICATIONS Input reflected ripple Conducted emissions (See Note 3) 110 g (3.88 oz) Bellcore 332 1,400,000 hours min. MIL-HDBK-217F 580,000 hours min. @ 40 °C, 100% full load ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating case temp. Non-operating -40 °C to +100 °C -55 °C to +125 °C Altitude Operating Non-operating 10,000 feet max. 40,000 feet max. Vibration 5-500 Hz 2.4 G rms (approx.) Embedded Power for Business-Critical Continuity Rev.03.08.07 bxb75s 3 of 4 Specifications Contd. OUTPUT POWER (MAX.) INPUT VOLTAGE OVP OUTPUT VOLTAGE OUTPUT CURRENT (MIN.) OUTPUT CURRENT (MAX.) EFFICIENCY (TYP.) LINE LOAD MODEL NUMBER (7, 9,10) 50 W 36-75 Vdc 75 W 36-75 Vdc 4.3 Vdc 3.3 V 0A 15 A 79% ±0.05% ±0.1% BXB75-48S3V3FLTJ 6.5 Vdc 5V 0A 15 A 83% ±0.05% ±0.1% BXB75-48S05FLTJ 75 W 36-75 Vdc 14.5 Vdc 12 V 0A 6.25 A 84% ±0.05% ±0.1% BXB75-48S12FLTJ REGULATION Notes PROTECTION 1 Short circuit Continuous, automatic recovery Overvoltage Non-latching Undervoltage Non-latching Measured with 10 μF tantalum capacitor and 1 μF ceramic capacitor across output. 2 di/dt = 0.1 A/1 μs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 0.75 lo max. and 0.75 lo max. to 0.5 lo max. 3 Units should be characterised within systems. External components required. 4 Input fusing is recommended based on surge current and maximum input current. 5 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 6 Simulated source impedance of 12 μH. 12 μH inductor in series with +Vin. 7 Active high remote on/off option is available (standard product is active low), designate with the suffix ‘FHT’ e.g. BXB75-48S05FHTJ. Consult factory for further details and options. 8 Start-up into resistive load. 9 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 10 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. Thermal 110 °C baseplate, automatic recovery TELECOM SPECIFICATION Central office interface A ETS300-132-2 EXTERNAL OUTPUT TRIMMING PIN CONNECTIONS PIN NUMBER FUNCTION 1 + Vin 2 Remote ON/OFF 3 Case 4 - Vin 5 - Vout 6 - Sense 7 Trim 8 + Sense 9 + Vout Output can be externally trimmed by using the method shown. 8 TRIM UP RT1 OR RT2 7 TRIM DOWN 6 Embedded Power for Business-Critical Continuity Rev.03.08.07 bxb75s 4 of 4 Americas VIEW SHOWN PIN SIDE UP 1.90 (48.26) 0.200 (5.08) Min. Length for all Input and Output Pins 0.190 (4.83) ± 0.010 (0.25) VI(+) Vo (-) +SEN TRIM -SEN 1.400 (35.56) ON/OFF 0.400 (10.16) 0.700 (17.77) 0.400 (10.16) 1.000 (25.40) 2.000 (50.80) 2.40 (60.96) Max. 1.400 (35.56) Vo(+) 1.000 (25.40) CASE VI (-) 0.500 (12.69) ± 0.010 (0.25) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 7 x Ø.040 (1.02) ±0.002 (0.05) 0.190 (4.83) ±0.010 (0.25) 2.28 (57.91) Max. 2 x Ø.080 (2.03) ± 0.002 (0.05) 4 x M3 x 0.5 Through ALL DIMENSIONS IN INCHES (mm) Tolerance : x.xx ±0.02in. (0.51mm) x.xxx ±0.010in. (0.254mm) 0.500 (12.70) Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 16th - 17th Floors, Lu Plaza 2 Wing Yip Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com [email protected] While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.