Embedded Power for Business-Critical Continuity Rev.2.13.09_154 UFE / UFR Series of 6 UFE / UFR Series Up to 6000 Watts Total Power: Input Voltage: # of Outputs: Output: Up to 6000 W 85 - 264 Vac Single + Aux 24 V & 48 V Special Features • Rack mounted chassis (1U, 19”) • 3 hot pluggable rectifiers per 1U chassis, up to 4 kW redundant or 6 kW available power (180-264 Vac input) • Up to 2.6 kW redundant or 3.9 kW available per shelf at 90-132 Vac input • Stackable to 6U high to provide up to 36 kW available power • Class B conducted EMI EN55022 (See Note 1) • Automatic fan speed control with fault reporting • Auxiliary standby output, 11 V at approximately 2.8 W • High density up to 22 W/in3 • High efficiency up to 91% • Floating as well as isolated main output voltage allows positive or negative polarity operation • EU directive 2002/95/EC compliant for RoHS • 2 year warranty • PMBus compliant Safety • VDE EN/IEC60950-1 • UL/cUL60950-1 Electrical Specifications Output Output Power: Main output Auxiliary output See Table 1 11 V ±15%, 2.875 W Line regulation: Low line to high line ±0.15% max. Load regulation (active share mode): Full load to min. load ±0.15% max. Turn-on delay: (See Note 4) 5.0 s max. Ambient temp. coefficient: At full load, min. Vin ±0.005%/ºC Voltage adjustability: Adjustable PMBus command (See Note 6) Output setpoint accuracy: 48 Vout 24 Vout 42-57 Vdc 21-28.5 Vdc Default output voltage: setting 25 ºC 48 Vout (active default) 24 Vout (active default) 48 V ± 0.5% @ 41 A 27 V ± 0.5% @ 48 A Voltage droop: (operation set PMBus command) 24 Vout 40.3 mV/A ± 3.0% from 10 A up to power limit 80.6 mV/A ± 3.0% from 10 A up to power limit ±0.5% 48 Vout Total error band: -40 ºC to +70 ºC, FL range ±1.0% max. Overshoot/undershoot: Main output @ turn-on/off 0%/0% Ripple and noise (20 MHz): Main output, -5 ºC and above Auxiliary output 500 mV pk-pk, 150 mV rms 400 mV pk-pk, 150 mV rms Dynamic regulation (except droop mode): Peak dev., 25% load step Recovery 2.5% max. time 1 ms max. (I1-I2) / ILIMIT x 100 15% max. Current sharing (See Note 3): All specifications are typical at nominal input, full load at 25 ºC ambient unless otherwise stated. Embedded Power for Business-Critical Continuity Rev.2.13.09_154 UFE / UFR Series of 6 Input Input voltage range: (See note 2) Input frequency range: Input current: Ground leakage current: Input fuse (internal) Power factor: Undervoltage lockout: (power up) Undervoltage lockout: (power down) 88-264 Vac 176-264 Vac 47-63 Hz 15 A max. 2 mA max. Notes 30 A 1 Final EMI performance is system/shelf dependent. 0.98 176 Vac max. 2 Auto ranging sets power limit based on input voltage at turn on. 88 Vac. max 3 The difference in output current among any two rectifiers operating in parallel does not 162 Vac min. exceed a value equal to 15% of the rated LED warning @ 176 V max. current limit. This specification applies for operation with any output current from no 76 Vac min. to 110% of maximum. LED warning @ 88 V max. 4 load Maximum 15 minute warm up time at light AC to safety ground Both lines fused 50 to 100% load High line range Wide line range High line range Wide line range General Specifications Electrical insulation: Switching frequency: Approvals and standards: Weight: Hold-up time: Input/output Input/chassis Fixed 3000 Vac / 4242 Vdc 1500 Vac / 2121 Vdc 450 kHz VDE EN/IEC60950-1 UL/CUL60950-1 5.5 lbs 20 ms min. 20 ms min. 279,069 hours 71 dB max. 58 dB typ. 48 Vout at rated output power 24 Vout at rated output power Telcordia SR-332 Issue 1 Over all conditions 25 ºC ambient at rated output power MTBF (@25 ºC): Acoustical noise: loads below -15˚C. See Application Note 212 for cold start timing data. 5 For operation above 1,524 m (5,000 ft), maximum operation temperature is derated by 2 ºC per 305 m (1,000 ft). 6 Output voltage can be modified on the fly between 21-28.5 V (24 V model) or 42-57 V (48 V model) PMBus command. 7 PM BUs communication. Pin names in parenthesis refer to the PMBus version names. UFE2000-96S48PJ and UFE130096S24PJ use PMBus. EMC Conducted emissions: Immunity: Harmonic current: ESD air/contact: Surge: Fast transients: Flicker: Magnetic field: Radiated immunity: Conducted immunity: EN55022, FCC part 15 Class B (when installed in system) EN61000-3-2 EN61000-4-2 EN61000-4-5 EN61000-4-4 EN61000-3-3 EN61000-4-8 EN61000-4-3 EN61000-4-6 Compliant Level 3 Level 3 Compliant Compliant Level 3 Level 3 Ordering Information Rated Output Power Output Voltage Vout Power Limit Output Line Range at Turn Operating Current Limit +15% / -0% Vout M������������� odel Numbers (7) Order������� Number Current (Min) On (Auto Ranging) Line Range (Vout) < Vout (min) (min) Min Max 1300 W 21 v 28.5 V 0A 1300 W 1300 W 2000 W 1300 W 2000 W 42 V 42 V 42 V 42 V 57 V 57 V 57 V 57 V 0A 0A 0A 0A 1300 W 2000 W 1300 W 2000 W 24 Vout Models 90-264 Vac 48 Vout Models 90-264 Vac 180-264 Vac 90-264 Vac 180-264 Vac 65 A 65 A 33 A 52 A 33 A 52 A 33 A 52 A 33 A 52 A UFE1300-96S24PJ UFE1300-5 UFE2000-96S48PJ UFE2000-9 UFE2000-96S48PDJ UFE2000-9-001 Rack Ordering Information Rack Model Number UFR6000 Hot Plug Interface Yes Number of Power Modules per Pack 3 Embedded Power for Business-Critical Continuity Rev.2.13.09_154 UFE / UFR Series of 6 Environmental Specifications Thermal performance: (See Notes 4 and derating curves) Operating Non-operating Cold Start -33 °C to +70 °C -40 °C to +100 °C -40 °C Relative humidity: non-condensing Operating Non-operating Up to 80% Up to 95% Altitude: (See Note 5) Operating Non-operating 10,000 feet max. 35,000 feet max. Vibration: Operating Non-operating 1.0 G peak 1.5 G peak Shock: Operating Non-operating 10 G peak / 11 �� ms 40 G peak / 11 ms Protection Power limit: Vo > Vout min ±Rated power +15%/-0% Current limit: Constant current limiting - brickwall Vo ² Vout min Short-circuit: Hiccup mode at Vo < 40 Vdc Vo < 20 Vdc Output shutdown Latching after 1 retry Overvoltage: ± limit, ± 8% 200 ms on / 1/8 s off 60 V max. 32 V max. Thermal: Self protecting OR-ing fault (See Note 7) Tested via I C or PMBus Non-latching LED alarm (by read) in case of OR-ing fault 2 Communication Monitoring Readout Accuracy Current: Valid from 15% to max. load Voltage: Measured before output OR-ing Temperature: Measured Internal output OR-ing ± 15% ± 5% ± 5 �� °C Hours counter: ± 36 s/hours approx. Part Number System with Options Product Family UFE UFE Rated Output Power Input Range 2000 2000 UFE = Universal 1300 = 1300 Watts 2000 = 2000 Watts Front-End Standard Compliance 9 9 9 = Universal Input with PFC 66 6 = UL/CSA/VDE Class A/B Type of Output Output Voltage SS 48 48 S = Single 48 = 48 V Communications Current Share Type C P D P = PMBus serial communications None = Active D = Droop RoHS Compliance (9) J J J = Pb free (RoHS 6/6 compliant) Embedded Power for Business-Critical Continuity Rev.2.13.09_154 UFE / UFR Series of 6 Mechanical Drawing 5.51 ± 0.02 (140.0 ±0.5) 9.58 ± 0.02 (243.3 ±0.5) WITH PEM SCREW FASTENED 10.74 ± 0.02 (272.8 ±0.5) FRONT FACE TO CONNECTOR 11.95 ± 0.03 (303.5 ±0.8) 5.56 ± 0.03 (141.2 ±0.8) 1.60 ± 0.02 (40.6 ±0.5) 0.17 ± 0.01 (4.3 ±0.3) Dimensions in Inches (mm) Power Supply Connector Mating Connector Molex: 87663-4006 Molex: 87664-2004 Pin Tyco: 2-1450330-8 Tyco: 1450370-5 P1 L1 FCI Berg: 51939-180 FCI Berg: 51915-070 P2 L2 P3 PEG Power Supply Connector SIGNAL POWER P1 P2 P3 1 2 3 4 5 6 P4 POWER P5 P6 P7 D C B A Power Connections Layout (Looking into Connector Side of UFE Power Supply) Power Supply Connector Pinout D C B A 1 Sense- Sense+ GND Shortpin 2 Present-L GND PS-ID0 GND 3 PS-ID3 PS-ID2 GND 12V-AUX 4 GND SCL PS-ID1 GND 5 SDA GND GND I2C-En-H (8) (Comm-En-H) 6 SMBALERT# P4 DC_N P5 DC_N P6 DC_P P7 DC_P Embedded Power for Business-Critical Continuity Rev.2.13.09_154 UFE / UFR Series of 6 Rack Specifications 0.13 (3.3) 0.22 (5.6) R0.13 (3.3) 1.250 (31.8) (5.6) 1.72 (43.8) 0.99 (25.1) 0.55 (14.0) 1.25 (31.8) 0.22 (5.6) 5.76 (146.3) 12.85 (326.4) 0.22 (5.6) 18.44 (468.4) 18.88 (475.6) 12.59 (319.8) 13.00 (330.2) 0.44 (11.2) 17.44 (443.0) max. Dimensions Inches (mm) Rack Signal Connector Pinout Signal Connector (1 per shelf) Function Shelf Connector Mating Connector 14 Ishare Molex: 52986-2679 Molex: 52316-2619 15 Unit 1 Present Tyco: 2-178238-4 Tyco: 2-5175677-4 Sense- 16 Ground 4 Ground 17 Unit 2 Present 5 PS-EN (Control) (8) 18 Ground 6 DC1-OK0-L 19 Unit 3 Present 7 DC2-OK-L 20 Ground Pin No. Function Pin No. 1 Sense+ 2 Ground 3 8 DC3-OK-L AC Input Connector (3 per shelf) Shelf Connector Mating Connector IEC320 C20 Socket IEC320 C20 Plug (Straight Entry) Shelf DIP Switch Table 21 SCL 9 I C-En-H-1 (Comm-En-H) (8) 22 Ground Shelf Number DIP Switch DIP Switch 10 I2C-En-H-2 (Comm-En-H) (8) 23 SDA 1 Up Up 11 I C-En-H-3 (Comm-En-H) 24 Ground 2 Up Down 2 2 (8) 12 Ground 25 SMBALERT# 3 Down Up 13 12V-Aux 26 N/C 4 Down Down Embedded Power for Business-Critical Continuity Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone:+1 760 930 4600 Facsimile: +1 760 930 0698 OUTPUT POWER (W) 1400 1300 All Output Voltages Below 120 Vac 1200 120 Vac to 149 Vac 1100 1000 40 45 50 55 60 65 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone:+44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 70 AMBIENT TEMPERATURE (ºC) Figure 1 - Thermal Derating Curve for UFE2000-96S48J Model Low Line Input Voltage 2100 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone:+852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: 2000 OUTPUT POWER (W) Rev.2.13.09_154 UFE / UFR Series of 6 www.PowerConversion.com 1900 Above 180 Vac 1800 52-57 V 48 V 42 V 1700 1600 techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 1500 1400 40 45 50 55 60 65 70 AMBIENT TEMPERATURE (ºC) Figure 2 - Thermal Derating Curve for UFE2000-96S48J Model High Line Input Voltage Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power 1400 POWER RATING (W) Embedded Computing Embedded Power 1300 Monitoring Outside Plant 1200 Power Switching & Controls 1100 Precision Cooling Racks & Integrated Cabinets 1000 Services 40 45 50 55 60 65 70 AMBIENT TEMPERATURE (ºC) Figure 3 - Thermal Derating Curve for UFE1300-96S24J Model All Conditions Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.