EMERSON-NETWORKPOWER IBC60

Embedded Power for
Business-Critical Continuity
Rev. 02.11.09_162
Quarter-Brick Fixed IBC60
of 4
Quarter-Brick
Series
Fixed Ratio 2nd
Generation IBC
Total Power: 600W
Input Voltage: 38 - 55VDC
Special Features
• 48 V input with isolated 9.6 V
output
• Ultra-high efficiency, 97%
• Unprecedented usable output
power levels
• High power density open-frame
technology
• Wide operating ambient
temperature range
• DOSA quarter-brick high
current footprint and pinout
• Low profile, 0.48” (12.2 mm)
• Meets basic insulation
requirements of EN60950-1
• Remote ON/OFF and
overtemperature protection
• RoHS compliant
• 2 Year Warranty
Electrical Specifications
Input
Input voltage ra­nge:
Input current:
Remote OFF
Input current (max.):
(See Note 1)
Input reflected ripple:
(See Note 4)
Remote ON/OFF
Logic compatibility
ON
OFF:
Undervoltage lockout:
Start-up time:
(See Note 3)
38-55 Vdc
6.5 mA typ.
13 A max. @ lo max.
and Vin = min. rated
1200 mA (pk-pk)
35 mA rms
(See Note 6)
Open collector ref. to -Input
> 2.4 Vdc
< 0.4 Vdc
Power up
Power down
Power up
Remote ON/OFF
34.5 V
33 V
11rms
2 rms
Low line to high line
Full load to min. load
See table
See Table
Output
Line regulation:
Load regulation:
Total error band:
Vin = 38 V to 55 V
(including setpoint, line, load and temperature)
7.0 - 11.0 Vdc
Safety
Minimum load:
0A
• UL/cUL : CAN/CSA 22.2
No. 60950-1 : UL60950-1
File No. E135734
Undershoot:
• VDE File No. 10401-3336-0206
Licence No. 40012752
Overshoot:
Ripple and Noise:
5-20 MHz
At turn-on and turn-off
None
None
(See Note 2)
100 mV pk-pk typ.
20 mV rms typ.
All specifications are typical at nominal input, full load at 25 °C ambient unless otherwise stated
Embedded Power for
Business-Critical Continuity
Rev. 02.11.09_162
Quarter-Brick Fixed IBC60
of 4
Electrical Specifications Continued
EMC Characteristics
Immunity:
ESD air enclosure:
EN61000-4-2 8 kV, 6 kV
Air, contact
Input transients:
Input voltage
Duration before shutdown
> 59 V
2 Seconds
> 60 V
1 Second
> 62 V
0 Seconds
General Specifications
Efficiency:
97%
Basic insulation:
Input/output
2250 Vdc
Switching frequency:
Fixed
340 kHz typ.
Approvals and (Pending) standards:
(See Note 5)
EN60950-1 VDE
UL/cUL60950-1
Material flammability:
UL94V-0
Weight:
MTBF representative model:
59 g (2.08 oz)
Telcordia Tech SR-332
48 Vin, 40 ˚C, 50% load
ground benign
TBD hours
Protection:
Short-circuit
Overvoltage:
Hiccup
(See Note 9)
Thermal
Non-latching
140 ˚C hot spot
Environmental Specifications
Thermal Performance:
Operating ambient temperature -40 ˚C - +85 ˚C
Non-operating
-55 ˚C to +125 ˚C
Embedded Power for
Business-Critical Continuity
Rev. 02.11.09_162
Quarter-Brick Fixed IBC60
of 4
Ordering Information
Ordering Information
Output
Power
(Max.)
Input
Voltage
Output
Voltage
Output
Current
(min.)
Output
Current
max.)
Efficiency
(typ)
642 W
38-55 Vdc
9.6 V
0A
60 A
97%
Part Number System with Options
Regulation
Set Point
Accuracy
--
Line %
Load %
32.5%
2.5%
Model Numbers
IBC60AQN4896J
IBC 60A Q N4896-RENJ
Product Family
IBC = Intermediate Bus Converter
2nd Generation
Rated Output Current
60 A = 60 Amps at 48 V
Form Factor
Q = Quarter-Brick
Input Voltage Type
T = Narrow Input Fixed Ratio
S = Narrow Input Semi-reguated
N = Narrow Telecom Fixed Ratio
W = Wide Telecom Semi-reguated
RoHS Compliance
J = Pb-free (RoHS 6/6 compliant)
Pin Length Options
Blank = 0.188 ” (4.78 mm)
N = 0.145 ” (3.68 mm)
K = 0.110 ” (2.79 mm)
Package, Body Height
E = Open-Frame, 0.48 in (12.2 mm)
Remote ON/OFF Logic
Blank = Positive
R = Negative (See Note 6)
Output Voltage
96 = 9.6 V
Input Voltage
48 = 48 V
Notes
1
2
3
4
5
6
7
8
9
Recommended input fusing is a 20 A HRC 250 V rated fuse.
Measured with external filter. See Application Note 209 for details.
Start-up into resistive load.
Peak to peak measured without external Pi filter. Significant reduction
possible with external filter. See Application Note 209 for details.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Active-low remote ON/OFF option is also available. Please add the suffix ‘-R’
to the part number, e.g. IBC60AQN4896-REJ.
Maximum output power at maximum input voltage.
Efficiency at 100% maximum output voltage.
After an input overvoltage latch off, the input voltage must be returned to 55
V or lower for unit to restart.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
­Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
2.300 (58.42)
0.140 (3.56)
2.000 (50.80)
Hotspot location for
thermal derating.
7
1
0.300 (7.62)
0.725 (18.42)
Rev. 02.11.09_162
Quarter-Brick Fixed IBC60
of 4
Europe (UK)
6
2
5
3
0.300 (7.62)
0.450 (11.43)
4
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
0.49 (12.45)
MAX
0.145 (3.68)
0.04 (1.0)
MIN
ø0.090 (2.35)
ø0.080 (2.03)
ø0.118 (3.00)
ø0.100 (2.54)
ø0.040 (1.02)
ø0.062 (1.57)
For global contact, visit:
www.powerconversion.com
2.300 (58.42)
0.145 (3.68)
ø0.100 (2.54)
(4 pls)
2.000 (50.80)
0.450 (11.43)
0.300 (7.62)
7
6
1
2
01.45 (36.8)
0.725 (18.42)
3
5
4
0.300 (7.62)
0.450 (11.43)
ø0.080 (2.03)
(3 pls)
RECOMMENDED HOLE PATTERN
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
x.xx 0.02 (x.x 0.5)
x.xxx 0.010 (x.xx 0.25)
øx.xxx 0.003 (øx.xx 0.08)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
Pin Connections
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Pin Number
Function
1
+ Vin
2
Remote ON/OFF
3
-Vin
4
+Vout
Power Switching & Controls
5
-Vout
6
+Vout
Precision Cooling
Racks & Integrated Cabinets
7
-Vout
Services
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2008 Emerson Electric Co.