EMERSON-NETWORKPOWER LPQ142

Embedded Power for
Business-Critical Continuity
Rev. 11.17.08_103
LPQ142 Series
of 3
LPQ142 Series
145 Watts
Total Power:
Input Voltage:
# of Outputs:
110 - 145 Watts
85-264 VAC
120-300 VDC
Quad
Electrical Specifications
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Active power factor correction
IEC EN61000-3-2 compliance
Adjustable outputs on 1, 3 & 4
Remote sense on main output
Single wire current sharing
Power fail and remote inhibit
Built-in EMI filter
Low output ripple
Overvoltage protection
Overload protection
Thermal overload protection
Adjustable floating 4th output
Optional cover (-C suffix)
Optional fan cover (-CF suffix)
VDE
UL
CB
CSA
CE
NEMKO
Input ra­nge:
85-264 VAC; 120-300 VDC
Frequency:
47-67 Hz
Inrush current:
38 A max, cold start @ 25°C
Efficiency:
EMI filter:
75% typical at full load
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Power Factor:
0.99 typical
Safety ground
leakage current:
1.0 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power:
80 W convection (60 W with cover -C)
145 W with 30 CFM forced air
(100 W with cover -C)
Adjustment range:
3.3 - 5.5V on main; -12 - 15V on 3rd output
3.3 - 25 V on 4th output
20 ms @175 W load at nominal line
Hold-up time:
Safety
•
•
•
•
•
•
Input
60950
60950
Certificate and report
60950
Mark (LVD)
EN 60950/EMKO-TUE
Overload protection:
hort circuit protection on all outputs. Case overload protected @
S
110-145% above peak rating
Overvoltage protection:
Tracks outputs 1, 3 & 4; 10 to 35%
Embedded Power for
Business-Critical Continuity
Rev. 11.17.08_103
LPQ142 Series
of 3
Logic Control
AC power failure:
TL logic signal goes high 100 - 500 msec after V1 output; It goes low
T
at least 4 msec before loss of regulation
Requires contact closure to inhibit outputs
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
TTL logic signal goes high after main output is in regulation. It goes low
when there is a loss of regulation
Remote inhibit:
Remote sense:
DC - OK:
Environmental Specifications
Temperature coefficient: ±0.4% per °C
Electromagnetic
Designed to meet IE61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
susceptibility:
Humidity:
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major
resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25°C ambient conditions
MTBF demonstrated:
Ordering Information
Minimum Maximum Load with
Load
Convection Cooling
Maximum Load
with 30CFM Peak Load 1 Regulation 2
Forced Air
Model
Number
Output
Voltage
LPQ142
5 V (3.3 - 5.5 V)
0A
12 A
25 A
27 A
±2%
50 mV
12 V
0A
5A
6A
9A
±3%
120 mV
-12V (-12 -15 V)
0A
1A
1.5 A
2A
±3%
<1%
Ripple P/P
(PARD)3
±3.3-25 V
0.5 A
1.5 A
4.5 A
5A
±3%
<50mV or 1%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. 4th output adjustable 3.3-25 V factory set at 5 V.
5. *Minimum loads are required when output set below 5 Volts
6. Remote inhibit resets OVP latch
Note: -C suffix added to the model number indicates cover option.
-CF suffix added to the model number indicates fan cover option.
SK1
SK2
SK4
Operating temperature: 0° to 50 °C ambient. Derate each output 2.5% per degree from 50° to
70 °C (except for -C version).
Storage temperature:
-40 °C to +85 °C
Vibration:
Pin Assignments
SK6
PIN 1
Ground
PIN 3
Neutral
PIN 5
Line
PIN 1
+12 V
PIN 2
Common
PIN 3
-12 V
PIN 4
Common
PIN 5
+5 V to +25 V (float)
PIN 6
Common (float)
TB-1
Common
TB-2
+5 V
PIN 1
N/C
PIN 2
DC OK
PIN 3
N/C
PIN 4
V1 SWP
PIN 5
Common
PIN 6
+V1 sense
PIN 7
Sense common
PIN 8
+ inhibit
PIN 9
- inhibit
PIN 10
Power fail
Mating Connectors
(SK1) AC Input:
(SK2) Aux DC Output:
(SK6) Control Signals:
(SK4) Main output:
Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
Molex 09-50-8061 (USA)
Molex 09-91-0600 (UK)
PINS: 08-58-0111
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Molex BB-19141-0058
Emerson Network Power connector kit #70-841-017,
includes al of the above.
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
­Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
V1 Adj
MAIN
OUTPUT
V4 Adj - Course
Europe (UK)
V4 Adj - Fine
6
V4V4+
COMM
-12V OUT
COMM
+12V OUT
SK2
L
1
N
5
GND
6
1
SK6
-CF option
M3
#6-32
(3X) 19.1
29.1
1.5
(38.1)
M3
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
10
SK1
Rev. 11.17.08_103
LPQ142 Series
of 3
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
(2X) 6.4
161.5
#6-32
171.5
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
4.00
(101.6)
(4X) 63.5
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
(2X) 119.6
(2X) 139.7
7.0
(177.8)
M3 (8 places)
#6-32 (8 places)
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 2 year
6. Weight: 1.63 lb / 0.74 kg
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2008 Emerson Electric Co.