Embedded Power for Business-Critical Continuity Rev. 04.14.06 LPS40-M Series 1 of 3 LPS40-M Series RoHS 40 Watts Medical Total Power: Input Voltage: # of Outputs: 40-55 Watts 85-264 VAC 120-300 VDC Triple Electrical Specifications Special Features • • • • • • • • • • • Medical safety approvals Universal input 3" x 5" footprint Less than 1U high Remote sense on main output Low output ripple Adjustable 5V output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Safety VDE UL CSA 0750/EN60601-1 (IEC601) UL2601 E182560 CSA 22.2 No.601.1 LR109492 CE Mark (LVD) Input Input range 85-264 VAC; 120-300 VDC Frequency 47-440 Hz Inrush current <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C Input current 1A max. (RMS) @ 115VAC Efficiency EMI filter 70% typical at full load FCC Class B conducted; CISPR 22 Class A conducted; EN55022 Class A conducted; VDE 0878 PT3 Class A conducted <75μA @ 50/60 Hz, 264 VAC input Safety ground leakage current Output Maximum power 40W for convection; 55W with 30CFM forced air Adjustment range -5, +10% minimum Hold-up time Overload protection 20ms @ 40W load, 115VAC nominal line Short circuit protection on all outputs Case overload protected @ 110 -145% above peak rating Overvoltage protection 5V output; 5.7 to 6.7VDC. Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.5 V lead drop minimum. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 04.14.06 LPS40-M Series 2 of 3 Environmental Specifications Operating temperature: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C Storage temperature: -40°C to +85°C Temperature coefficient: ±0.4% per °C Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% RH Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational >550,000 hours at full load and 25°C ambient conditions MTBF demonstrated: Ordering Information Maximum Load Model Output Minimum Maximum Load with with 30CFM Number Voltage Load Convection Cooling forced Air LPS42-M 5V 0A 8A 11A Peak Load 1 Regulation 2 (PARD) 3 12A ±2% 50 mV LPS43-M 12V 0A 3.3A 4.5A 5A ±2% 120 mV LPS44-M 15V 0A 2.6A 3.6A 4A ±2% 150mV LPS45-M 24V 0A 1.6A 2.3A 2.5A ±2% 240mV Ripple P/P 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. Power Derating Curve 55W 30 CFM Forced Air Cooling 40W 30W Output Power (Watts) 20W Natural Convection Cooling 27.5W 20W 10W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C Embedded Power for Business-Critical Continuity Mechanical Drawing Astec Power 0.22" (5.6) 5.00" (127) 4.55" (115.6) M1 GND SK201 3.00" (76.2) _ 1 2 3 4 5 6 2.55" (64.8) SK 1 N 3 1 M2 + Remote Sense Connector Voltage Adj. Pot SK 2 L 0.15" (4) DIA (4 places) Rev. 04.14.06 LPS40-M Series 3 of 3 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Technical Support: +1 888 41 ASTEC or +1 407 241 2752 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Units 2111-2116, Level 21 Tower 1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: +852 2437 9662 Facsimile: +852 2402 4426 For global contact, visit: www.astecpower.com [email protected] 1.14" (29) While every precaution has been taken to ensure accuracy and completeness in this literature, Astec Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 0.12" (3) Printed in US A Mating Connectors Pin Assignments Connector LPS42-M LPS43-M LPS44-M LPS45-M SK1-1 SK1-3 Neutral Line Neutral Line Neutral Line Neutral Line SK2-1 SK2- 2 SK2- 3 +5V +5V +5V +12V +12V +12V +15V +15V +15V +24V +24V +24V SK2-4 Common Common Common Common SK2-5 SK2-6 SK201-1 SK201-2 Common Common +Sense -Sense Common Common +Sense -Sense Common Common +Sense -Sense Common Common +Sense -Sense AC Input: Molex 09-50-8031 (USA) 09-91-0300 (UK) PINS: 08-58-0111 DC Outputs: Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK) PINS: 08-58-0111 Remote Sense: Molex 22-01-2025 PINS: 08-50-0114 Astec Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm) 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. 5. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. Warranty: 1 year Weight: 0.5lbs/0.23kg 6. 7. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co.