EMERSON-NETWORKPOWER LPQ252-C

Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_157
LPQ250 Series
of 3
LPQ250 Series
250 Watts
Total Power: 250 Watts
Input Voltage: 85-264 Vac
120 - 300 Vdc
# of Outputs: Quad
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Active power factor correction
IEC EN61000-3-2 compliance
Remote sense on main output
Power fail and remote inhibit
Single wire current sharing
Built-in EMI filter
Adjustable floating 4th output
2 Supervisory outputs 5 V and 12 V
Overvoltage protection
Overload protection
Thermal overload protection
DC power good
120 KHz switching frequency
Cover -C
Optional with fan cover -CF
Optional end fan cover -CEF
Safety
•
•
•
•
•
•
0805/EN60950 (IEC950)
11774-3336-1262
UL
UL1950 EI32002
CSA CSA 22.2-234 Level 5
LR53982C
NEMKO EN 60950/EMKO-TUE
P95102999 (74-sec) 203
CB
Certificate & report 2186
CE
Mark (LVD)
VDE
Electrical Specifications
Input
Input ra­nge:
85-264 Vac; 120 - 300 Vdc
Frequency:
47-440 Hz
Inrush current:
20 A max, cold start @ 25 °C
Efficiency:
75% typical at full load
EMI filter:
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and radiated
Safety ground
leakage current:
< 0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power:
With cover: 250 W with 30 CFM forced air.
(-C) (-CF) (CEF)
Adjustment range:
± 5% min. on main: 5-25 V on 4th output
Supervisory outputs:
Hold-up time:
5 V @ 100 mA regulated, 12 V @ 500 mA
16 ms @ 250 W load, 115 VAC nominal line
Overload protection:
Short circuit protection on all outputs. Case overload protected @
110-145% above peak rating
Overvoltage protection:
5 V output: 5.7 to 6.7 VDC.
Other models 10% to 25% above nominal output
Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_157
LPQ250 Series
of 3
Logic Control
Power fail:
TTL Logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 ms before loss of regulation
Remote on/off:
Requires an external contact (N.O or N.C) to inhibit outputs
DC-OK:
TTL logic goes high 50-150 msec after the output. It goes low when there is loss of regulation.
Remote sense:
Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse
connection protected
Environmental Specifications
Operating temperature:
0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70 °C
-40 °C to +85 °C
Storage temperature:
Temperature coefficient: ± 0.4% per °C
Electromagnetic
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
susceptibility:
Humidity:
Operating; non-condensing 5% to 95%
Vibration:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5 Hz to
500 Hz, operational
MTBF demonstrated:
> 550,000 hours at full load and 25 °C ambient conditions
Ordering Information
Model Number
Output Voltage
Minimum Load
LPQ252-C
+5 V
+12 V
-12 V
± 5 - 25 V
+5 V
+15 V
-15 V
± 5 - 25 V
3A
0A
0A
0A
3A
0A
0A
0A
LPQ253-C
Maximum Load with
30CFM Forced Air
35 A
10 A
6A
6A
35 A
10 A
6A
6A
Peak Load 1
Regulation 2
Ripple P/P (PARD)3
40 A
12 A
8A
8A
40 A
12 A
8A
8A
±2%
±3%
±3%
±3%
±2%
±3%
±3%
±3%
50 mV
120 mV
120 mV
240 mV max.
50 mV
150 mV
150 mV
240 mV max.
1.Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2.At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3.Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4.4th output 5 - 25 V factory set at 5 V.
5. Minimum Load is required.
6.If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required through the length of the power supply. Not
convection rated.
Note: -CF suffix added to the model number indicates cover with top fan. -CEF suffix added to the model number indicates cover with dual end
mounted fan cover and AC inlet.
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
­Americas
#6-32 (2 places)
M3 (2 places)
M3 (8 places)
M3
6-32 (2 places)
(6 places)
Main Output
SK2
SK3
#6-32 UNC (2 places) Terminal
M3
Block TB1
6 5 4 3 2 1 12345678
10.0
#6-32 UNC (8 places)
.24 (6.1)
10.0
SK5
+ve -ve
4th O/P ADJ.
O/P ADJ.
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
3.68
(93.6)
SK7
FAN
5.46
(138.6)
6.64
(168.6)
8.52
(216.4)
9.0
(228.6)
10.32
(262.0)
2.17
(55)
10.0
6-32 (3 places)
#6-32 UNC
(2 places)
Optional
(-CEF)
Cover
with fans
3 2 1
SK1
5.0 (127.0)
.55
(14)
1.18 (30.0)
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
2.0
(50.8)
3.0
(76.2)
1.30
(33.0)
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
AC Inlet
.79
(20)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
SK4
FAN
Optional
(-CF)
3.15
Cover
(80)
with Fan
M3
3.42 (87.0)
Emerson Network Power.
The global leader in enabling
business-critical continuity.
Pin Assignments
Mating­ Connectors
Connector
SK3
Molex 22-01-1084
PINS:08-70-0057
SK4
Molex 22-01-3027
PINS: 08-50-0114
AC Power
SK5
Molex 22-01-3027
PINS: 08-50-0114
Connectivity
SK7
Molex 22-01-3027
PINS: 08-50-0114
DC Power
SK1
SK2
SK3
SK4
SK5
SK7
PIN 1
PIN 2
PIN 3
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
Neutral
PIN 1
+ Remote sense
Pin 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 1
PIN 2
PIN 1
PIN 2
PIN 1
PIN 2
- Remote sense
Rev. 2.16.09_157
LPQ250 Series
of 3
Line
Ground
+ 12 / 15V
Common
Common
- 12 / 15 V
Emerson Network Power Connector Kit #70-841-005, includes all of the above.
Embedded Computing
5-25 V RET Float
1. Specifications subject to change without notice.
Embedded Power
5-25 V Float
­2. All dimensions in inches (mm), tolerance is ± 0.02”­­ (± 0.5mm)
Remote inhibit (N.O.)
Remote inhibit (N.C.)
Common
Current sharing
Power Fail
DC Power Good
+ Fan’s power source (12 V @ 500 mA)
- Fan’s power source (12 V @ 500 mA)
+ Supervisory output supply (5 V @ 100 mA)
- Supervisory output supply (5 V @ 100 mA)
+ Fan’s power source (12 V @ 500 mA)
- Fan’s power source (12 V @ 500 mA)
3. Specifications are at factory settings.
Monitoring
4. To enable normally closed remote inhibit, cut jumper J1.
Outside Plant
5. Mounting maximum insertion depth is 0.12”.
6. Warranty: 2 years
7. Weight: 3.1 lb / 1.41 kg
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2008 Emerson Electric Co.