EMERSON-NETWORKPOWER LPT100-M

Embedded Power for
Business-Critical Continuity
Rev. 10.9.09_141
LPT100-M Series
of 3
LPT100-M Series
130 Watts
Total Power:
Input Voltage:
# of Outputs:
80 - 130 Watts
90 - 264 Vac
Triple
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Medical and ITE safeties
Active power factor correction
2” x 4” footprint
Less than 1U high
EN61000-3-2 compliant
Remote sense
Power fail
Adjustable main output
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Thermal overload protection
LPX50 enclosure kit available
Electrical Specifications
Input
Input ra­nge:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
90 - 264 Vac; 127 - 300 Vdc
47 - 63 Hz
50 A max., cold start @ 25 °C
82% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
275 µA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
80 W for convection;
130 W with 200 LFM forced air
Adjustment range:
All outputs adjustable - 40%, +10%, except for +24V output on LPT104-M
which will be -10%, +20% and 3.3 V output on the LPT101-M +10%, -15%
Hold-up time:
10 ms @ 130 W load, 120 Vac input
Overload protection: Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 110-190% for V3
Overvoltage protection: 15 - 35% above nominal output
Logical Control
Power failure:
Safety
•
•
•
•
•
•
•
TUV 60950, 60601-1
UL
60950, 60601-1
CSA
60950, 60601-1
NEMKO
60950, 60601-1
AUSTEL
60950, 60601-1
CB
Certificate & report
CE
Mark (LVD)
Remote sense:
Active LowTTL logic signal goes high 100 - 500 msec after main output; it
goes low at least 6 msec before loss of regulation
Compensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Rev. 10.9.09_141
LPT100-M Series
of 3
Operating temperature:
Storage temperature:
Electromagnetic
susceptibility:
0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C. -20 °C start up
-40 °C to +85 °C
designed to meet EN61000-4;
-2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95%
Vibration:
IEC68-2-6 to the levels of IEC721-3-2
MTBF calculated:
583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore
Mechanical Drawing
Output Voltage
Adjust Pots
SK3
1.72”
(43.8)
2.00”
(50.8)
GND
PIN 1 (LIVE)
PIN 3 (NEUTRAL)
SK2
SK1
3.73”
(94.6)
4.00”
(101.6)
0.10”
(2.5)
1.28”
(32.7)
Output Voltage
Adjust Pots
Mounting Hole
ø0.16” [4.0] 4 Places
Max. Screw Head
Diameter .22” (5.6)
0.197” (5.0) Minimum
Standoff height
Embedded Power for
Business-Critical Continuity
­Americas
Ordering Information
Model
Number
LPT101-M
LPT102-M
LPT103-M
LPT104-M
Maximum Load Maximum Load
Output Minimum
with Convection
with 30CFM
Voltage
Load
Cooling
Forced Air
+3.3 V
0A
13 A
18 A
Peak
Load
Regulation2
Ripple
P/P
(PARD)3
20 A
±2%
50 mV
+5 V
0A
5A
9A
10 A
±5%
50 mV
+12 V
0A
1A
2.3 A
2.3 A
±5%
120 mV
+5 V
0A
13 A
18 A
20 A
±2%
50 mV
+12 V
0A
5A
9A
10 A
±5%
120 mV
-12 V
0A
1A
2A
2A
±5%
120 mV
+5 V
0A
13 A
18 A
20 A
±2%
50 mV
+15 V
0A
4A
7.2 A
8A
±5%
150 mV
-15 V
0A
1A
1.5 A
2A
±5%
150 mV
+5 V
0A
13 A
18 A
2A
±2%
50 mV
+24 V
0A
1.5 A
3A
3.5 A
±7%
240 mV
+12 V
0A
1A
2.3 A
2.3 A
±5%
120 mV
1. Peak current lasting < 15 seconds with a maximum 10% duty cycle.
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 10.9.09_141
LPT100-M Series
of 3
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
For global contact, visit:
3­. Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges.
www.PowerConversion.com
Pin Assignments
Connector SK1
PIN 1
PIN 3
SK2
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
SK3
PIN 1
PIN 2
PIN 3
PIN 4
Mating­ Connectors
LPT100-M
Neutral
Line
V1out
V1out
GND
GND
GND
GND
V2out
V3out
Power Fail
GND
+ Remote Sense
- Remote Sense
AC Input (SK1):
Molex P/N 09-50-8031
PINS: 08-52-0113
AC Ground:
Molex P/N 01-9002001
DC Output (SK2):
JST P/N VHR-8N
PINS: SVH-21T-P1.1
Remote Sense (SK3): Molex P/N 87639-0400
PINS: 50212-8100
Emerson Network Power Connector Kit #70-841-026, includes
all of the above
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. mounting holes MH1, MH2, MH3 should be grounded for
EMI purpose
4. Mounting MH1 is safety ground connection
5. Specifications are for convection rating at factory settings
at 115 Vac input 25 °C unless otherwise stated.
6. This power supply requires mounting on metal standoffs
0.20” (5 m) in height.
7. Warranty: 2 year
8. Weight: 0.44 lb. / 0.20 kg
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection