Embedded Power for Business-Critical Continuity SXX06E Rev. 08.01.06 Page 1 of 2 Rev. 07.02.08 SIL40C2 1 of 5 SIL40C2 Series 4.5-13.8 Vin Single C-Class Non-Isolated 40 A Current Rating Input Voltage: 4.5-13.8 V No. of Outputs: Single Electrical Specifications Special Features •40 A current rating •Input voltage range: 4.5-13.8 V •Output voltage: 0.6-5 V •Industry leading value • Cost optimized design •Excellent transient response •Output enable •Output voltage adjustability • Pathway for future upgrades • Supports silicon voltage migration • Resulting in reduced design-in and qual time •RoHS Compliant Output Output voltage See Note 5 Output setpoint accuracy 0.1% trim resistors ±1.0% Line regulation Low line to high line ±0.2% Load regulation Full load to min. load Min./max. load 0.6-5 V ±0.5% 0 A/40 A Overshoot At turn-on 0.5% max. Undershoot At turn-off 100 mV max. Ripple and noise 5 Hz to 20 MHz See Note 1 Transient response See Notes 1, 2 25 mV Vin=5 V, Vout=2.5 V 130 mV max. deviation 50 µs recovery to within regulation band Input Input voltage range Safety UL, cUL CAN/CSA 22.2 No. E139421 UL6950 File No. TBD TÜV Product Service (EN60950) Certificate No. TBD CB report and certificate to IEC60950 4.5-13.8 Vdc Input current Minimum load Remote OFF Input current (max.) See Note 3 Start-up time Remote ON/OFF 50 mA 5 mA 25 A @ lo max. 3 ms Embedded Power for Business-Critical Continuity Rev. 07.02.08 SIL40C2 2 of 5 General Efficiency Vin=5 V, Vo=2.5 V, lo=20 A Switching frequency Fixed 94% 500 kHz EN60950 UL/cUL6950 Approvals and standards (pending) Material flammability UL94V-0 Weight 17 g (0.06 oz.) MTBF 12 V @ 40 °C, 100% load Bellcore 332 6,749,409 hours Coplanarity 150 µm Environmental Specifications Thermal performance See Note 5 Operating ambient, temperature Non-operating 0 °C to +70 °C -40 °C to +125 °C Protection Short-circuit Hiccup, non-latching Overvoltage protection Hiccup, non-latching Recommended System Capacitance Input capacitance See Note 6 0 µF Output capacitance See Note 7 0 µF Ordering Information Output Power (Max.) Input Voltage OVP Output Voltage Output Current (Min.) Output Current (Max.) Efficiency (Typical) 200 W 4.5-13.8 Vdc N/A 0.6-5 Vdc 0A 40 A 94% ±0.2% ±0.5% SIL40C2-00SADJ-VJ 200 W 4.5-13.8 Vdc N/A 0.6-5 Vdc 0A 40 A 94% ±0.2% ±0.5% SIL40C2-00SADJ-HJ 200 W 4.5-13.8 Vdc N/A 0.6-5 Vdc 0A 40 A 94% ±0.2% ±0.5% SMT40C2-00SADJJ Regulation Line Load Model Number (3,5) Embedded Power for Business-Critical Continuity Part Number System with Options Product Family Rated Output Current Performance Rev. 07.02.08 SIL40C2 3 of 5 Generation SIL 40 C 2 Product Family SIL = Single In Line SMT = Surface Mount Rated Output Current 06 = 6 A 15 = 15 A 20 = 20 A 30 = 30 A 40 = 40 A Performance C = Cost Optimized Generation Blank = Standard Part 2 = Increased Current Density Output Voltage Adjustment of the SIL40C2 Series Input Voltage - Output Voltage 00 SADJ Input Voltage 00 = 4.5-13.8 V Output Voltage Single Adjustable Output Mounting Option - V J Mounting Option V = Vertical H = Horizontal RoHS Compliance J = Pb-free RoHS 6/6 Compliant Standard Application Drawing The ultra-wide output voltage trim range offers major advantages to users who select the SIL40C2 series. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 0.6-5 V. When the SIL40C2 converter leaves the factory, the output has been adjusted to the default voltage of 0.6 V. Notes: 1 Measured as per recommended system capacitance. 2 di/dt = 10 A/µs, Vin = Nom, Tc = 25 °C, load change = 0.75 lo to full lo and full lo to 0.75. 3 External input fusing is recommended. 4 Additional part numbers may be available with different output voltages. 5 Airflow dependent, 100 LFM minimum required. 6 No capacitors needed for ripple current capability. 7 No capacitors needed for stability. 8 TSE RoHS 5/6 (non-Pb-free) compliant versions are also available on special request, please contact our local sales representative for details. 9 NOTICE: Some models may not support all options. Please contact your local representative or use the on-line model number search tool at http://www. powerconversion.com to find a suitable alternative. 10 To order a Horizontal Mounting option with a pin length of 0.165", please use the model # SIL40C2-00SA-HP5J RoHS Compliance(8) Power Good 6 Enable 5 V out 1,2,3 9 +R sense SIL40C2 V in 10,11 7,8 C out 4 C in R trim (for trim down) GND Figure 1: Standard Application Drawing R L O A D Embedded Power for Business-Critical Continuity Rev. 07.02.08 SIL40C2 4 of 5 Mechanical Drawings Dimensions in inches (mm). Tolerances (unless otherwise specified) 2 Places ±0.030 (±0.76) 3 Places ±0.010 (±0.25) Vertical Mount 1.200 (30.48) 0.427 (10.85) 0.255 (6.48) 1.100 (27.94) 0.062 (1.57) REF 0.110 (2.79) 0.050 (1.27) REF PIN 1 Pin Assignments 0.140 (3.56) TYP 0.100 (2.54) 0.100 (2.54) TYP 9 PLACES 1.050 (26.67) 0.050 (1.27) TYP 0.025 (0.64) ±.001 SQ PINS TYP Horizontal Mount 1.200 (30.48) Function Vout Vout Vout Trim Enable Power Good Ground Ground (+) Sense Vin Vin *Mech support *Mech support *Horizontal and SMT version only Dimensions in Inches (mm) 0.468 (11.89) Tolerances (unless otherwise specified) 2 Places ±0.030 (±0.76) 0.062 (1.57) REF 3 Places ±0.010 (±0.25) 0.255 (6.48) Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 1.100 (27.94) .150 (3.81) TYP PIN 1 0.110 (2.79) REF 2X 1.000 (25.40) 0.025 (0.64) ±.001 SQ PINS TYP 13 PLACES 0.100 (2.54) TYP 9 PLACES 0.050 (1.27) REF 2X 1.050 (26.67) 0.050 (1.27) 0.100 (2.54) REF Embedded Power for Business-Critical Continuity SXX06E Rev. 08.01.06 Page 1 of 2 Surface Mount Dimensions in inches (mm). Tolerances (unless otherwise specified) 2 Places ±0.030 (±0.76) 3 Places ±0.010 (±0.25) 0.062 (1.57) REF 0.125 (3.18) TYP 0.442 (11.23) 0.255 (6.48) 0.110 (2.79) REF 1.200 (30.48) Americas Rev. 07.02.08 SIL40C2 5 of 5 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Europe (UK) 1.100 (27.94) 2X 1.000 (25.40) 0.050 (1.27) REF PIN 1 0.100 (2.54) TYP 9 PLACES Pin Assignments Pin No. Function 1 Vout 2 Vout 3 Vout 4 Trim in Inches (mm) Dimensions 5 Enable Tolerances (unless otherwise specified) 26Places ±0.030 Power Good (±0.76) (±0.25) 37Places ±0.010 Ground 8 Ground 9 (+) Sense 10 Vin 11 Vin 12 *Mech support 13 *Mech support *Horizontal and SMT version only 2X 1.050 (26.67) 0.050 (1.27) 0.100 (2.54) REF Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.