EXCELICS RFMA0912-2W

RFMA0912-2W
9.50 – 11.70 GHz Power Amplifier MMIC
UPDATED 10/05/2007
FEATURES
•
•
•
•
9.50– 11.70GHz Operating Frequency Range
32.5dBm Output Power at 1dB Compression
30.0 dB Typical Power Gain @ 1dB Gain Compression
-41dBc Typical OIM3 @ each tone Pout 21.5dBm
Excelics
RFMA0912
-2W
APPLICATIONS
•
•
Point-to-point and point-to-multipoint radio
Military Radar Systems
Caution! ESD sensitive device.
ELECTRICAL CHARACTERISTICS (Ta = 25 °C, 50 ohm, Vdd=7V, Vgg=-5V)
SYMBOL
PARAMETER/TEST CONDITIONS
MIN
TYP
MAX
UNITS
11.70
GHz
Operating Frequency Range
9.50
P1dB
Output Power at 1dB Gain Compression
31.5
32.5
dBm
G1dB
Gain @ 1dB gain compression
Output 3rd Order Intermodulation Distortion
@∆f=10MHz, Each Tone Pout 21.5dBm
27.0
30.0
dB
F
OIMD3
Input RL
Output RL
-41
-38
dBc
Input Return Loss
-12
-8
dB
Output Return Loss
-15
-10
dB
Idd
Drain Current
1900
2150
mA
Vdd
Drain Voltage
7
8
V
Vgg
Gate Voltage
-5
Rth
Thermal Resistance (Au-Sn Eutectic Attach)
4.0
Tb
Operating Base Plate Temperature
-30
V
o
4.5
C/W
+80
ºC
CONTINUOUS
1,2
MAXIMUM RATINGS @25°C
SYMBOL
CHARACTERISTIC
ABSOLUTE
VDD
Drain Supply Voltage
12V
8V
VGG
Gate Supply Voltage
-8V
-3V
IDD
Drain Current
Idss
3.6A
IGG
Gate Current
240mA
40mA
PIN
Input Power
20dBm
@ 3dB compression
TCH
Channel Temperature
175°C
150°C
TSTG
Storage Temperature
-65/175°C
-65/150°C
30.0W
25.2W
PT
Total Power Dissipation
1. Operating the device beyond any of the above rating may result in permanent damage.
2. Bias conditions must also satisfy the following equation Vdd*Idd < (TCH –Tb)/RTH; where Tb = operating base plate temperature
Specifications are subject to change without notice.
Excelics Semiconductor, Inc. 310 De Guigne Drive, Sunnyvale, CA 94085
Phone: 408-737-1711 Fax: 408-737-1868 Web: www.excelics.com
page 1 of 2
Revised October 2007
RFMA0912-2W
9.50 – 11.70 GHz Power Amplifier MMIC
UPDATED 10/05/2007
P3 Package Outline
0.472
0.236
4X.050 CHAMFER
4X DIA 0.098 THRU
PIN1 Indicator
0.130
N/C
Excelics
RFMA0912
-2W-P3
RF IN
0.709
Vg
Vd
4X 0.150
0.591
RF OUT
6 X .013
N/C
6X 0.100±0.010
0.075
6X 0.004
0.040
0.025
All dimensions in inches
DISCLAIMER
EXCELICS SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE
TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. EXCELICS DOES NOT
ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT
DESCRIBED HEREIN.
LIFE SUPPORT POLICY
EXCELICS SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS
IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF EXCELICS
SEMICONDUCTOR, INC.
AS HERE IN:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body,
or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for
use provided in the labeling, can be reasonably expected to result in significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be
reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Specifications are subject to change without notice.
Excelics Semiconductor, Inc. 310 De Guigne Drive, Sunnyvale, CA 94085
Phone: 408-737-1711 Fax: 408-737-1868 Web: www.excelics.com
page 2 of 2
Revised October 2007