FB1267 Filter Shape Bandpass Centre Frequency F0 36.0 MHz Insertion Loss at F0 < 3.5 dB (typically 2.9 dB) Passband 36 ± 10 MHz 2 < 0.2 dB1 pk-pk (target) Passband Amplitude Ripple < 0.3 dB1 pk-pk (spec.) < 4 ns1 (target) Passband Group Delay Ripple < 6 ns1 (spec.) Attenuation at 53.5 MHz wrt 36 MHz > 55 dB Stopband Attenuation wrt 36 MHz > 50 dB from 67 to 100 MHz > 40 dB from 100 to 150 MHz > 28 dB below 22.3 MHz (target) > 25 dB below 22.3 MHz (spec.) 1 2 Impedance 50 ohms Operating Temperature 0°C to 70°C Aqueous Washable No Package DR00237A When measured against system response values in table 1. Passband Amplitude Ripple typically increases by 0.1 dB over temperature range. Table 1 Frequency MHz 26 27 28 29 30 31 32 33 34 35 36 Amplitude dB 0 -0.009 -0.023 -0.036 -0.049 -0.059 -0.069 -0.077 -0.084 -0.091 -0.098 Delay ns 0 -1.699 -3.119 -4.305 -5.293 -6.117 -6.808 -7.388 -7.876 -8.285 -8.626 Frequency MHz 37 38 39 40 41 42 43 44 45 46 Amplitude dB -0.105 -0.113 -0.121 -0.128 -0.138 -0.147 -0.157 -0.168 -0.179 -0.192 Delay ns -8.908 -9.133 -9.308 -9.432 -9.508 -9.533 -9.510 -9.435 -9.308 -9.124 © Faraday Technology. As part of continual product improvement the specifications, details and dimensions shown in this publication are subject to change without notice Fara142s.doc Page 1 of 2 Jan-01(C) PACKAGE DETAIL Faraday Technology Ltd. Croft Road Industrial Estate, Newcastle, Staffordshire ST5 0QZ. England. Fara142s.doc Tel: Fax: Email: Web site: Page 2 of 2 + 44 (0)1782 661501 + 44 (0)1782 630101 [email protected] http://www.faradaytech.co.uk Jan-01(C)