CORE SETS
Effective core parameters
14.05 ±0.25
handbook, halfpage
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
1.02
mm−1
Ve
effective volume
495
mm3
Ie
effective length
22.5
mm
Ae
effective area
22.0
mm2
Amin
minimum area
19.9
mm2
m
mass of set
≈ 2.5
g
11.8 ±0.2
8.6 min.
9.4
±0.15
5.9 ±0.1
3.1 ±0.075
5.8
±0.2
8.3
±0.15
CBW110
Dimensions in mm.
Fig.1 PTS14/8 core set.
Core sets for general purpose transformers and power applications
Clamping force for AL measurements, 15 ±15 N.
GRADE
3C81
3C91
3F3
µe
63 ±3%
≈ 51
≈ 590
PTS14/8-3C81-A63
100 ±3%
≈ 81
≈ 340
PTS14/8-3C81-A100
160 ±3%
≈ 130
≈ 190
PTS14/8-3C81-A160
250 ±3%
≈ 204
≈ 110
PTS14/8-3C81-A250
315 ±5%
≈ 257
≈ 90
PTS14/8-3C81-A315
2330 ±25%
≈ 1900
≈0
2330 ±25%
TYPE NUMBER
PTS14/8-3C81
≈ 1900
≈0
63 ±3%
≈ 51
≈ 590
PTS14/8-3F3-A63
100 ±3%
≈ 81
≈ 340
PTS14/8-3F3-A100
PTS14/8-3C91
160 ±3%
≈ 130
≈ 190
PTS14/8-3F3-A160
250 ±3%
≈ 204
≈ 110
PTS14/8-3F3-A250
315 ±5%
≈ 257
≈ 90
PTS14/8-3F3-A315
≈ 1320
≈0
1625 ±25%
2008 Sep 01
AIR GAP
(µm)
AL
(nH)
1043
PTS14/8-3F3
Ferroxcube
PTS14/8
(1408THS)
PT, PTS, PTS/I cores and accessories
Core sets of high permeability grades
Clamping force for AL measurements, 15 ±5 N.
GRADE
3E27
AL
(nH)
µe
AIR GAP
(µm)
4370 ±25%
≈ 3540
≈0
TYPE NUMBER
PTS14/8-3E27
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
3C81
≥320
≤ 0.1
−
−
−
3C91
≥320
−
3F3
≥315
−
GRADE
≤
≤
0.026(1)
−
0.19 (1)
≤ 0.054
−
≤ 0.94
Note
1. Measured at 60 °C.
BOBBINS AND ACCESSORIES
For coil formers, winding data and mounting parts, see data sheet, “P14/8” and “PT14/8”, but “area product” is different.
Winding data and area product (for PTS14/8) for 6-pins PT14/8 coil former
NUMBER OF
SECTIONS
MINIMUM
WINDING
AREA
(mm2)
NOMINAL
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
7.9
4.1
29.2
174
TYPE NUMBER
CPV-PT14/8-1S-6P
Winding data and area product (for PTS14/8) for CP-P14/8 coil former
NUMBER OF
SECTIONS
WINDING
AREA
(mm2)
MINIMUM
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
TYPE NUMBER
1
8.8
4.1
28.9
194
CP-P14/8-1S
2
2 × 4.0
2 × 1.85
28.9
2 x 88.0
CP-P14/8-2S
2008 Sep 01
1044
Ferroxcube
PTS14/8
(1408THS)
PT, PTS, PTS/I cores and accessories
Winding data and area product (for PTS14/8) for CP-P14/8-A coil former
NUMBER OF
SECTIONS
MINIMUM
WINDING
AREA
(mm2)
NOMINAL
WINDING
WIDTH (mm)
AVERAGE
LENGTH OF
TURN
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
9.4
4.5
29.0
207
CP-P14/8-1S-A
2
2 x 4.32
2 x 2.0
29.0
2 x 95.0
CP-P14/8-2S-A
3
3 × 2.19
3 × 1.2
29.0
3 x 48.2
CP-P14/8-3S-A
TYPE NUMBER
Winding data and area product (for PTS14/8) for 4-pins P14/8 coil former for PCB mounting
NUMBER
OF
SECTIONS
MINIMUM
WINDING
AREA
(mm2)
NOMINAL
WINDING
WIDTH
(mm)
AVERAGE
LENGTH
OF TURN
(mm)
LENGTH
OF PINS
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
8.65
4.4
29.0
4.4
190
CPV-P14/8-1S-4SPD
1
8.65
4.4
29.0
6.8
190
CPV-P14/8-1S-4SPDL
2
2 × 3.87
2 × 2.0
29.0
4.4
2 x 85.1
CPV-P14/8-2S-4SPD
2
2 × 3.87
2 × 2.0
29.0
6.8
2 x 85.1
CPV-P14/8-2S-4SPDL
TYPE NUMBER
Winding data and area product (for PTS14/8) for 6-pins P14/8 coil former for PCB mounting
NUMBER
OF
SECTIONS
MINIMUM
WINDING
AREA
(mm2)
NOMINAL
WINDING
WIDTH
(mm)
AVERAGE
LENGTH
OF TURN
(mm)
LENGTH
OF PINS
(mm)
AREA
PRODUCT
Ae x Aw
(mm 4)
1
8.65
4.4
29.0
4.4
190
CPV-P14/8-1S-6PD
1
8.65
4.4
29.0
6.8
190
CPV-P14/8-1S-6PDL
2
2 × 3.87
2 × 2.0
29.0
4.4
2 x 85.1
CPV-P14/8-2S-6PD
2
2 × 3.87
2 × 2.0
29.0
6.8
2 x 85.1
CPV-P14/8-2S-6PDL
2008 Sep 01
1045
TYPE NUMBER
Ferroxcube
PTS14/8
(1408THS)
PT, PTS, PTS/I cores and accessories
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
1046