FERROXCUBE PTS40-3C94

FERROXCUBE
DATA SHEET
PTS40/27/I
PT, PTS, PTS/I cores and
accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
PT, PTS, PTS/I cores and accessories
PTS40/27/I
CORE SETS
+ 0.2
− 0.7
+ 0.2
33.2
− 0.6
20 min
39.8
Effective core parameters
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.346
mm−1
Ve
effective volume
14400
mm3
Ie
effective length
70.5
mm
Ae
effective area
204
mm2
Amin
minimum area
201
mm2
m
mass of set
≈ 66
g
28.3
± 0.35
16 ± 0.25
19.7
± 0.3
26.9
± 0.2
MFP060
Dimensions in mm.
Fig.1 PTS40/27/I core set.
Core sets for general purpose transformers and power applications
Clamping force for AL measurements, 100 ± 25 N.
AIR GAP
(µm)
AL
(nH)
µe
3C92
4740 ± 25 %
≈ 1300
≈0
PTS40/27/I-3C92
3C94
6800 ± 25 %
≈ 1870
≈0
PTS40/27/I-3C94
3C96
6060 ± 25 %
≈ 1670
≈0
PTS40/27/I-3C96
GRADE
TYPE NUMBER
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 500 kHz;
ˆ = 50 mT;
B
T = 100 °C
3C92
≥320
≤ 1.5
≤ 8.6
−
3C94
≥320
≤ 1.5
≤ 8.6
−
3C96
≥315
≤ 1.1
≤ 6.5
≤ 5.4
GRADE
2008 Sep 01
1080
Ferroxcube
PT, PTS, PTS/I cores and accessories
PTS40/27/I
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
1081