Effective core parameters
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.280
mm−1
Ve
effective volume
6200
mm3
Ie
effective length
42
mm
Ae
effective area
148
mm2
Amin
minimum area
125
mm2
m
mass of set
≈ 35
g
29.8
0
−1.1
handbook, halfpage
16.1 0 5
−0.5
>12.9
0
−1.3
37.4
∅12.8 0
−0.4
0
9 +0.5 16.8
−0.2
0
13.8
±0.25
∅25 +1
0
CBW133
Dimensions in mm.
Fig.1 RM12/ILP core set.
Core sets for general purpose transformers and power applications
Clamping force for AL measurements, 70 ±20 N.
GRADE
AL
(nH)
AIR GAP
(µm)
µe
TYPE NUMBER
3C90
7100 ±25%
≈1600
≈0
RM12/ILP-3C90
3C94
7100 ±25%
≈1600
≈0
RM12/ILP-3C94
3C95
8470 ±25%
≈1915
≈0
RM12/ILP-3C95
3C96
6700 ±25%
≈1510
≈0
RM12/ILP-3C96
3F3
6700 ±25%
≈1510
≈0
RM12/ILP-3F3
3F35
5000 ±25%
≈ 1110
≈0
RM12/ILP-3F35
3F4
3600 ±25%
≈ 810
≈0
RM12/ILP-3F4
2008 Sep 01
2
Ferroxcube
RM, RM/I, RM/ILP cores and accessories
RM12/ILP
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 25 °C
3C90
≥315
≤ 0.75
≤ 0.79
−
−
−
3C94
≥315
−
≤ 0.62
−
≤ 3.3
−
3C95
≥315
−
−
≤ 3.66
≤ 3.47
−
3C96
≥315
−
≤ 0.49
−
≤ 2.6
≤ 1.1
3F3
≥300
−
≤ 0.68
−
−
≤ 1.2
3F35
≥300
−
−
−
−
−
3F4
≥250
−
−
−
−
−
GRADE
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
Properties of core sets under power conditions (continued)
B (mT) at
GRADE
3C90
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 500 kHz;
ˆ = 50 mT;
B
T = 100 °C
f = 500 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 30 mT;
B
T = 100 °C
f = 3 MHz;
ˆ = 10 mT;
B
T = 100 °C
≥315
−
−
−
−
3C94
≥315
−
−
−
−
3C95
≥315
−
−
−
−
3C96
≥315
≤ 2.2
−
−
−
3F3
≥300
−
−
−
−
3F35
≥300
≤ 0.85
≤ 6.5
−
−
3F4
≥250
−
−
≤ 1.8
≤ 3.0
2008 Sep 01
3
Ferroxcube
RM, RM/I, RM/ILP cores and accessories
RM12/ILP
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
4