GAMEWELL-FCI GV-MP96P-RC

Description
600 Series
Fire Command Center
Multiplexed Voice
Evacuation System
The Gamewell Voice (GV) Multiplexed Evacuation System
Fire Command Center operates in conjunction with the 600
Series Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies.
The Gamewell Voice Master Panel Fire Command Center
includes all necessary features to provide an effective Voice
Evacuation and Fire Alarm Control system. The Gamewell
Voice Panel can be easily custom configured to satisfy the
needs of any configured Voice System application.The
Gamewell Voice Fire Command Center comes complete with
the Gamewell RS-484 Intelligent Interface Software for communication to the Gamewell FACP. All Fire Alarm and Voice
Communication control are combined in a visually appealing single panel configuration.
Fire Department authorities easily take command of
evacuation, relocation procedures and emergencies from a
single Fire Command Center. Building management and Fire
Brigades easily monitor and control emergency responses
even before the professionals arrive.
Approvals
The GV system includes capacity for 6 channel digital audio. This provides for evacuation, stay-in-place, or other public address announcements and automatic messages, and
fire fighter phones.
Features
Fire Fighter Phones or Warden Stations may be included
as required. Smoke control, stair pressurization, and HVAC
shutdown can be completely automatic, unless controlled
manually by management or fire authorities, utilizing the associated Gamewell FACP.
System Configuration
Basic System includes:
Master Panel (GV-MPXX-RC, GV-MPXXP-RC)
Master Microphone Control
Remote Fire Annunciation and Control
Switch Control points
Dual Channel Digital Message Repeator
High Speed RS-485 communication loop
Optional
Integrated Master Fire Phone
UL Listed, MEA Approved
•
•
•
•
•
•
•
•
•
•
•
True Multiplex 6 Channel Distributed Audio
Complete Fire Alarm Control Functions
Integrated Fire Phone, paging and manual EVAC
Modular System - components added as needed
Integrated 2 Channel Digital Message Repeater
Live Microphone Page to any zone
Fully Supervised
Natural Sound Voice Recordings
Built-in Alarm and Alert Signals
Up to 4 minute message capacity
All Voice control and audio data on single high speed
communications loop
•
•
3 minute message restart on microphone key
1000 Monitor & Control Points
CS-2176 09/01/06
Page 1
Specifications
Primary Power:
Electrical Ratings
Communications Bus:
Voltage:
Current:
Impedance:
Frequency:
Backbox Dim:
Color:
120 VAC 24 VDC Battery Power
(All Circuits @ 24VDC.)
RS-485 Standard, 1M Baud data rate, Category 5 cable.
5V peak-to-peak max.
50mA max.
120 Ohms (max. imp. between panels)
1.024MHz
14.5 x 27 x 4“ w h d
RED - standard
Master Panel Components:
Standby
GV-DCC
80 mA
GV-ASC
30 mA
GV-MFP
10 mA
GV-SSC
25 mA
Alarm
80 mA
30 mA
10 mA
25 mA
GV-SLC
GV-MMC
GV-I/O cards
Standby
6 ma
45 ma
20 ma
Alarm
6 ma
45 ma
20 ma
Ordering Information
Master Panel Fire Command Center Configurations
GV-MP16-RC
GV-MP32-RC
GV-MP48-RC
GV-MP64-RC
GV-MP80-RC
GV-MP96-RC
GV-MP112-RC
GV-MP128-RC
GV-MP144-RC
Master
Master
Master
Master
Master
Master
Master
Master
Master
Panel,
Panel,
Panel,
Panel,
Panel,
Panel,
Panel,
Panel,
Panel,
GV-MP16P-RC
GV-MP32P-RC
GV-MP64P-RC
GV-MP80P-RC
GV-MP96P-RC
GV-MP112P-RC
GV-MP128P-RC
Master Panel,
Master Panel,
Master Panel,
Master Panel,
Master Panel,
Master Panel,
Master Panel,
16 Switch Control, Remote Fire Contol
32 Switch Control, Remote Fire Contol
48 Switch Control, Remote Fire Contol
64 Switch Control, Remote Fire Contol
80 Switch Control, Remote Fire Contol
96 Switch Control, Remote Fire Contol
112 Switch Control, Remote Fire Contol
128 Switch Control, Remote Fire Contol
144 Switch Control, Remote Fire Contol
16 Switch Control, Master Fire Phone, Remote Fire Contol
32 Switch Control, Master Fire Phone, Remote Fire Contol
64 Switch Control, Master Fire Phone, Remote Fire Contol
80 Switch Control, Master Fire Phone, Remote Fire Contol
96 Switch Control, Master Fire Phone, Remote Fire Contol
112 Switch Control, Master Fire Phone, Remote Fire Contol
128 Switch Control, Master Fire Phone, Remote Fire Contol
For systems requiring more switch controls then indicated above please contact Gamewell Corporate Marketing.
All systems require Distributed Panels (DP) for operation.
Panel Options: Cards may be added as job requirements demand
GV-MFP
GV-MMC-RC
GV-SSC
GV-SLC
GV-IIC
GV-OI
Master Fire Phone
Master Mic & RAN/RC
Switch Scan Card
Switch LED Card
Input Interface card
Output Interface Card
Enables system to incorporate 2 way communication. Included with “P” panels.
Master Microphone Control & Gamewell RAN2-RC with mounting Place.
Included in basic panels, up to 7 additional cards may be added.
16 LED Switch Bank card, up to 8 per GV-SSC.
16 FACP input card. Provides hard wire interface to FACP. (128 pts max)
16 FACP output card. Provides hard wire interface. (128 pts max)
Custom messages available. Please contact factory.
Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no
responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the
product shall always be used for actual installation. For more information, contact Gamewell-FCI.
Gamewell-FCI
12 Clintonville Road
Northford, CT 06472
Tel: (203) 484-7161
FAX: (203) 484-7118
www.gamewell-fci.com
©Gamewell-FCI 2006
CS-2176 09/01/06
Page 2