Description 600 Series Fire Command Center Multiplexed Voice Evacuation System The Gamewell Voice (GV) Multiplexed Evacuation System Fire Command Center operates in conjunction with the 600 Series Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. The Gamewell Voice Master Panel Fire Command Center includes all necessary features to provide an effective Voice Evacuation and Fire Alarm Control system. The Gamewell Voice Panel can be easily custom configured to satisfy the needs of any configured Voice System application.The Gamewell Voice Fire Command Center comes complete with the Gamewell RS-484 Intelligent Interface Software for communication to the Gamewell FACP. All Fire Alarm and Voice Communication control are combined in a visually appealing single panel configuration. Fire Department authorities easily take command of evacuation, relocation procedures and emergencies from a single Fire Command Center. Building management and Fire Brigades easily monitor and control emergency responses even before the professionals arrive. Approvals The GV system includes capacity for 6 channel digital audio. This provides for evacuation, stay-in-place, or other public address announcements and automatic messages, and fire fighter phones. Features Fire Fighter Phones or Warden Stations may be included as required. Smoke control, stair pressurization, and HVAC shutdown can be completely automatic, unless controlled manually by management or fire authorities, utilizing the associated Gamewell FACP. System Configuration Basic System includes: Master Panel (GV-MPXX-RC, GV-MPXXP-RC) Master Microphone Control Remote Fire Annunciation and Control Switch Control points Dual Channel Digital Message Repeator High Speed RS-485 communication loop Optional Integrated Master Fire Phone UL Listed, MEA Approved • • • • • • • • • • • True Multiplex 6 Channel Distributed Audio Complete Fire Alarm Control Functions Integrated Fire Phone, paging and manual EVAC Modular System - components added as needed Integrated 2 Channel Digital Message Repeater Live Microphone Page to any zone Fully Supervised Natural Sound Voice Recordings Built-in Alarm and Alert Signals Up to 4 minute message capacity All Voice control and audio data on single high speed communications loop • • 3 minute message restart on microphone key 1000 Monitor & Control Points CS-2176 09/01/06 Page 1 Specifications Primary Power: Electrical Ratings Communications Bus: Voltage: Current: Impedance: Frequency: Backbox Dim: Color: 120 VAC 24 VDC Battery Power (All Circuits @ 24VDC.) RS-485 Standard, 1M Baud data rate, Category 5 cable. 5V peak-to-peak max. 50mA max. 120 Ohms (max. imp. between panels) 1.024MHz 14.5 x 27 x 4“ w h d RED - standard Master Panel Components: Standby GV-DCC 80 mA GV-ASC 30 mA GV-MFP 10 mA GV-SSC 25 mA Alarm 80 mA 30 mA 10 mA 25 mA GV-SLC GV-MMC GV-I/O cards Standby 6 ma 45 ma 20 ma Alarm 6 ma 45 ma 20 ma Ordering Information Master Panel Fire Command Center Configurations GV-MP16-RC GV-MP32-RC GV-MP48-RC GV-MP64-RC GV-MP80-RC GV-MP96-RC GV-MP112-RC GV-MP128-RC GV-MP144-RC Master Master Master Master Master Master Master Master Master Panel, Panel, Panel, Panel, Panel, Panel, Panel, Panel, Panel, GV-MP16P-RC GV-MP32P-RC GV-MP64P-RC GV-MP80P-RC GV-MP96P-RC GV-MP112P-RC GV-MP128P-RC Master Panel, Master Panel, Master Panel, Master Panel, Master Panel, Master Panel, Master Panel, 16 Switch Control, Remote Fire Contol 32 Switch Control, Remote Fire Contol 48 Switch Control, Remote Fire Contol 64 Switch Control, Remote Fire Contol 80 Switch Control, Remote Fire Contol 96 Switch Control, Remote Fire Contol 112 Switch Control, Remote Fire Contol 128 Switch Control, Remote Fire Contol 144 Switch Control, Remote Fire Contol 16 Switch Control, Master Fire Phone, Remote Fire Contol 32 Switch Control, Master Fire Phone, Remote Fire Contol 64 Switch Control, Master Fire Phone, Remote Fire Contol 80 Switch Control, Master Fire Phone, Remote Fire Contol 96 Switch Control, Master Fire Phone, Remote Fire Contol 112 Switch Control, Master Fire Phone, Remote Fire Contol 128 Switch Control, Master Fire Phone, Remote Fire Contol For systems requiring more switch controls then indicated above please contact Gamewell Corporate Marketing. All systems require Distributed Panels (DP) for operation. Panel Options: Cards may be added as job requirements demand GV-MFP GV-MMC-RC GV-SSC GV-SLC GV-IIC GV-OI Master Fire Phone Master Mic & RAN/RC Switch Scan Card Switch LED Card Input Interface card Output Interface Card Enables system to incorporate 2 way communication. Included with “P” panels. Master Microphone Control & Gamewell RAN2-RC with mounting Place. Included in basic panels, up to 7 additional cards may be added. 16 LED Switch Bank card, up to 8 per GV-SSC. 16 FACP input card. Provides hard wire interface to FACP. (128 pts max) 16 FACP output card. Provides hard wire interface. (128 pts max) Custom messages available. Please contact factory. Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell-FCI. Gamewell-FCI 12 Clintonville Road Northford, CT 06472 Tel: (203) 484-7161 FAX: (203) 484-7118 www.gamewell-fci.com ©Gamewell-FCI 2006 CS-2176 09/01/06 Page 2