GENNUM GO1515-CTA

HD-LINX ™ GO1515
Voltage Controlled Oscillator
DATA SHEET
DESCRIPTION
• generates 1.485GHz or 1.485/1.001GHz signal for
HD-LINX™ ICs
The GO1515 is a self contained, miniature Voltage
Controlled Oscillator (VCO) that is used in conjunction with
Gennum’s HD-LINX™ ICs. It produces a clean 1.485GHz
reference clock signal for such devices as the GS1515
HDTV Reclocker and other HD-LINX™ devices. The control
voltage range is from 3.10 volts to 4.65 volts and is derived
from the on-chip PLLs. The GO1515 frequency can be
pulled approximately 16MHz for every one volt of control.
• low current consumption
• 50Ω output impedance
• operates from a single 5V supply
• 8 pin tape on reel
APPLICATIONS
The output level is approximately 1.0dBm with low spurious
and noise content. It is designed to drive 50Ω strip lines.
VCO for the following HD-LINX™ ICs: GS1515, GS1522,
GS1540, GS1545.
The GO1515 VCO is used with the following HD-LINX™ ICs;
GS1515, GS1522, GS1540, GS1545 and is ordered as a
separate item. The VCO requires a single 5V supply and
draws a maximum of 15mA of current. It is packaged in a
miniature 8-pin proprietary surface mount package and
operates over the normal commercial temperature range of
0°C to +70°C.
ORDERING INFORMATION
PART NUMBER
PACKAGE
TEMPERATURE
GO1515 - CTA
8 pin tape on reel
0°C to 70°C
VCTR
VCC
47pF
1000pF
STRIPLINE
STRIPLINE
3.3pF
2pF
OUT
OSCILLATOR CIRCUIT
GND
BLOCK DIAGRAM
Revision Date: March 2000
Document No. 522 - 40 - 02
GENNUM CORPORATION P.O. Box 489, Stn. A, Burlington, Ontario, Canada L7R 3Y3
Tel. +1 (905) 632-2996 Fax. +1 (905) 632-5946 E-mail: [email protected]
www.gennum.com
GO1515
FEATURES
ELECTRICAL CHARACTERISTICS
VS = 5.0V ±0.25V, Temperature = 0°C to 70°C unless otherwise specified.
GO1515
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Supply Voltage
VCC
4.75
5.0
5.25
V
Supply Current
ΙS
-
-
15
mA
Control Voltage Range
VCTR
+3.1
-
+4.65
V
Control Voltage Sensitivity
df/dV
11
16
21
MHz/V
Operating Frequency
Range
ƒVCO
1483.5
-
1485.5
MHz
Output Signal Level
VOUT
-2
1
+4
dBm
Signal to Noise Ratio
S/N
40
-
-
dB
74
-
-
dBc
Signal Level: 1kHz ±8kHz
Deviation = 0.3~3.0kHz
Carrier to Noise Ratio
C/N
25kHz Separation, 1kHz Bandwidth
Pushing Figure
VS = 5.0V ±0.25V, ref: VS = 5.0V
-
±500
-
kHz
Pulling Figure
VSWR = 2.0 for all phase, ref: 50Ω
-
±1000
-
kHz
0°C to 70°C, ref. = 25°C
-
-
±3
MHz
-
-
-10
dBc
-
50
-
Ω
Temperature Stability
TCOEF
Spurious Response
Output Impedance
ZO
PIN CONNECTIONS
GND
NC
GND
O/P
7
6
5
GO
1515
8
4
GND
TOP VIEW
1
2
3
VCTR
GND
VCC
NOTE: Pin numbers are arbitrary.
There are no pin markings on the device itself
PIN DESCRIPTIONS
NUMBER
SYMBOL
TYPE
DESCRIPTION
2, 4, 6, 8
GND
-
Most negative power supply connections.
1
VCTR
I
Control voltage for the VCO.
3
VCC
-
Most positive power supply connection.
5
O/P
O
VCO signal output.
7
NC
-
No connection.
2
522 - 40 - 02
65
NC
55
40
GND
55
OUT
GND
GND
40
VCTR
GND
65
GO1515
GO1515
TOP VIEW
45
VCC
All dimensions are in mils
1 mil = 1/1000 inch
Fig. 1 Footprint of the GO1515
DIMENSIONS
NC
GND
VCTR
GND
GO1515
TOP VIEW
GND
OUT
GND
4.2 6.0
2.0
±0.3 ±0.3 MAX
VCC
1.6±0.5
2.0 MAX
4.7±0.3
6.3±0.3
All dimensions in millimetres.
7.8 MAX
SOLDERING RECOMMENDATIONS
Reflow Conditions
Soldering Conditions
The device will meet the data sheet specifications after
completing the reflow process according to the profile
shown in Figure 3. Do not reflow the device more than
twice.
Recommended soldering conditions are as follows:
Reflow Soldering
Endurance To Warp
When the device is soldered on a printed circuit board
(dimension: 100mm x 100mm; thickness: 1.6mm) and the
PCB is warped as shown in Figure 2, the device will not be
cracked or damaged.
Preheating
150±10°C, 60 to 120 sec.
Soldering
Peak 230±5°C
Over 200°C within 30 sec.
Soldering Flux
Do not use cleaning type flux. Washing the devices after
using cleaning type flux may damage inner parts and affect
performance.
VCO
Solder Type
PCB
MAX 2mm
Use solder H60, H63 (in JIS Z 3282) or an equivalent type.
This also applies to solder paste.
Fig. 3 PCB Warp
3
522 - 40 - 02
230 ± 5
GO1515
TEMPERATURE (˚C)
200
160
30 sec
140
60 to 120 sec
60 sec
TIME (sec.)
Fig. 3 Reflow Profile
HANDLING RECOMMENDATIONS
Cleaning
Do not wash the devices.
Storage
Use within 6 months after delivery. If the devices are stored
for more than one year, solderability may be degraded.
Store the devices out of direct sunlight, at a stable
temperature and humidity. Avoid extreme temperatures,
high humidity and wide temperature fluctuations.
Condensation on the devices may result in reduced quality
and lowered solderability.
Avoid dust, sea breezes and corrosive gases (Cl2, NH3,
SO2, NOX, etc.).
CAUTION
ELECTROSTATIC
SENSITIVE DEVICES
DO NOT OPEN PACKAGES OR HANDLE
EXCEPT AT A STATIC-FREE WORKSTATION
REVISION NOTES:
Added Soldering and Handling sections and figures.
DOCUMENT IDENTIFICATION
DATA SHEET
The product is in production. Gennum reserves the right to make
changes at any time to improve reliability, function or design, in order to
provide the best product possible.
For latest product information, visit www.gennum.com.
GENNUM JAPAN CORPORATION
C-101, Miyamae Village, 2-10-42 Miyamae, Suginami-ku
Tokyo 168-0081, Japan
Tel. +81 (03) 3334-7700 Fax. +81 (03) 3247-8839
GENNUM CORPORATION
MAILING ADDRESS:
P.O. Box 489, Stn. A, Burlington, Ontario, Canada L7R 3Y3
Tel. +1 (905) 632-2996 Fax. +1 (905) 632-5946
GENNUM UK LIMITED
25 Long Garden Walk, Farnham, Surrey, England GU9 7HX
Tel. +44 (0)1252 747 000 Fax +44 (0)1252 726 523
SHIPPING ADDRESS:
970 Fraser Drive, Burlington, Ontario, Canada L7L 5P5
Gennum Corporation assumes no responsibility for the use of any circuits described herein and makes no representations that they are free from patent infringement.
© Copyright June 1999 Gennum Corporation. All rights reserved. Printed in Canada.
522 - 40 - 02
4