GPSEMI GC11830F

Green Power Solutions srl
Via Greto di Cornigliano 6R - 16152 Genova , Italy
Phone: +39-010-659 1869
Fax: +39-010-659 1870
Web: www.gpsemi.it
E-mail: [email protected]
GC118…F
BAR CLAMP FOR HOCKEY PUK DEVICES
Clamping total thikness of assembly from
21mm to 125mm
Pre-loaded to the specific clamping
force (22 ÷ 32 kN)
Maximum device diameter: 105mm
Surface passivation to provide extra protection
Hexagon head bolt partially
threaded M8x1.25, UNI5737, 8.8 steel
Various lengths of bolts and insulators
Flat clamping head for optimal clamping
force application
Four styles available
User friendly clamping force indicator
UL94 certified insulation material
Parameter
Weight
Clamping Force*
Unit
g
kN
Types
Testing
conditions
Values
Notes
Min
GC118S…F
GC118B…F
22
GC118…24F
24
GC118…30F
GC118…32F
30
32
± 10%
VRMS
Insulating Material
3000
E121562
110
Max. working temperature
°C
Creepage distance:
mm
28
Clearance distance:
mm
20.3
Flammability
*
1 min
Noryl  ∗∗
UL File
Storage temperature
-30
°C
110
-40
mm
UL94 V-1 Flame class rating
1.5
mm
UL94 V-0 Flame class rating
8.00
mm
CSA Flammability
1.00
Other clamping forces available: contact factory

** Noryl is a registered trade mark of General Electric
Document GC118…FT001
Max
1030
1870
GC118…22F
Clamping Force tolerance
Insulation Voltage
Typ
930
1750
GC118…F
BAR CLAMP FOR HOCKEY PUK DEVICES
ORDERING INFORMATION TABLE
GC118
Clamps can be ordered using the following part numbering system
(1) Construction type:
B
N
B
A
24
(1)
(2)
(3)
(4)
(5)
F
B = with double bar
S = with single bar
(2) Insulator position:
N = upper side
(3) Insulator code:
(4) Bolt code:
(5) Clamping force (in kN):
see table below
see table below
K
22
K
R = lower side
24
30
32
(6) Special accessories
blank = no accessories
K: Total thickness of the assembly to be clamped
S = extra bar spacer
For thicknesses S' Min < K < S Min an additional 4mm thick bar spacer is needed (see list of special accessories)
Type GC118BN…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Bolt choice
Max height
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
T [mm]
21
25
40
A
50
Z
100
117
31
35
50
B
70
A
110
127
41
45
60
B
70
B
120
137
51
55
70
C
95
C
130
147
61
65
80
C
95
D
140
157
71
75
90
C
95
E
150
167
81
85
100
D
120
F
160
177
** with additional metal spacer only
Type GC118BR…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
Bolt choice
Max height
(4)
Bolt Length [mm]
T [mm]
21
25
40
A
50 ***
Z
100
129
31
35
50
A
50
A
110
139
41
45
60
A
50
B
120
149
51
55
70
B
70
C
130
159
61
65
80
B
70
D
140
169
71
75
90
C
95
E
150
179
81
85
100
C
95
F
160
189
** with additional metal spacer only
*** For S Max
Type GC118SN…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
21
25
40
A
31
35
50
B
41
45
60
51
55
61
Bolt choice
Max height
(4)
Bolt Length [mm]
T [mm]
50
Z
100
110
70
A
110
120
B
70
B
120
130
70
C
95
C
130
140
65
80
C
95
D
140
150
71
75
90
C
95
E
150
160
81
85
100
D
120
F
160
170
** with additional metal spacer only
Type GC118SR…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Bolt choice
Max height
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
T [mm]
46
50
65
B
70
Z
100
129
56
60
75
B
70
A
110
139
66
70
85
B
70
B
120
149
76
80
95
C
95
C
130
159
86
90
105
C
95
D
140
169
96
100
115
D
120
E
150
179
106
110
125
D
120
F
160
189
** with additional metal spacer only
Document GC118…FT001
S
(6)
GC118…F
BAR CLAMP FOR HOCKEY PUK DEVICES
BAR CLAMP OUTLINES
T
22.5
22.5
67
143
39
143
Ø12
S
106
106
25
Ø12
118
25
118
GC118BN...F
GC118BR...F
143
118
GC118SN...F
T
22.5
22
Ø12
S
106
50 UP TO 120
22.5
25 14
143
106
Ø12
118
GC118SR...F
Dimensions in mm - Tolerances according to ISO 2768 MK
Document GC118…FT001
GC118…F
BAR CLAMP FOR HOCKEY PUK DEVICES
S' Min
S Max
OPTIONAL BAR SPACER
S Min
PRESSURE DISC
SPECIAL ACCESSORIES
The following special accessories are available on request (see ordering information table)
145
4
Ø13
25
Bar spacer
Dimensions in mm - Tolerances according to ISO 2768 MK
In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without
notice.
Document GC118…FT001