GPSEMI GC7005F

Phone: +39-010-659 1869
Fax: +39-010-659 1870
Web: www.gpsemi.it
E-mail: [email protected]
Green Power Solutions srl
Via Greto di Cornigliano 6R - 16152 Genova , Italy
GC70…F
BAR CLAMP FOR HOCKEY PUK DEVICES
Clamping total thikness of assembly from
44mm to 135mm
Pre-loaded to the specific clamping
force (5 ÷ 12 kN)
Maximum device diameter: 57mm
Surface passivation to provide extra protection
Hexagon head bolt partially
threaded M8x1.25, UNI5737, 8.8 steel
Various lengths of bolts and insulators
Flat clamping head for optimal clamping
force application
Four styles available
User friendly clamping force indicator
UL94 certified insulation material
Parameter
Weight
Clamping Force*
Unit
g
kN
Types
Testing conditions
Values
Notes
Min
'GC70S…F
GC70B…F
340
430
05
GC70…08F
08
GC70…10F
GC70…12F
10
12
± 10%
VRMS
1 min
3000
Insulating Material
Noryl  ∗∗
UL File
E121562
Max. working temperature
°C
Creepage distance:
mm
Clearance distance:
mm
Storage temperature
°C
Flammability
110
-30
28
20.3
110
-40
mm
UL94 V-1 Flame class rating
1.5
mm
UL94 V-0 Flame class rating
8.00
mm
CSA Flammability
1.00
* Other clamping forces available: contact factory

** Noryl is a registered trade mark of General Electric
Document GC70…FT001
Max
460
570
GC70…05F
Clamping Force tolerance
Insulation Voltage
Typ
GC70…F
BAR CLAMP FOR HOCKEY PUK DEVICES
ORDERING INFORMATION TABLE
GC70
Clamps can be ordered using the following part numbering system
(1) Construction type:
B
N
B
A
10
(1)
(2)
(3)
(4)
(5)
F
B = with double bar
S = with single bar
(2) Insulator position:
N = upper side
(3) Insulator code:
(4) Bolt code:
(5) Clamping force (in kN):
see table below
R = lower side
K
K
see table below
05
08
10
12
(6) Special accessories
blank = no accessories
K: Total thickness of the assembly to be clamped
S = extra bar spacer
For thicknesses S' Min < K < S Min an additional 4mm thick bar spacer is needed (see list of special accessories)
Type GC70BN…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Bolt choice
Max height
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
T [mm]
44
48
63
A
50
Z
100
110
54
58
73
B
70
A
110
120
64
68
83
B
70
B
120
130
74
78
93
C
95
C
130
140
84
88
103
C
95
D
140
150
94
98
113
C
95
E
150
160
104
108
123
D
120
F
160
170
** with additional bar spacer only
Type GC70BR…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Max height
3
Bolt choice
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
44
48
63
A
50
54
58
73
A
50
64
68
83
B
70
B
120
143
74
78
93
B
70
C
130
153
84
88
103
C
95
D
140
163
94
98
113
C
95
E
150
173
104
108
123
C
95
F
160
183
(4)
Bolt Length [mm]
T [mm]
Z
100
123
A
110
133
** with additional bar spacer only
Type GC70SN…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
44
48
63
A
54
58
73
B
64
68
83
74
78
84
88
94
98
113
104
108
123
Bolt choice
Max height
Bolt Length [mm]
T [mm]
50
Z
100
110
70
A
110
120
B
70
B
120
130
93
C
95
C
130
140
103
C
95
D
140
150
C
95
E
150
160
D
120
F
160
170
4
(4)
** with additional bar spacer only
Type GC70SR…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Max height
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
T [mm]
56
60
75
B
70
Z
100
123
66
70
85
B
70
A
110
133
76
80
95
B
70
B
120
143
86
90
105
C
95
C
130
153
96
100
115
C
95
D
140
163
106
110
125
D
120
E
150
173
116
120
135
D
120
F
160
183
** with additional bar spacer only
#
Bolt choice
S' Min [mm]**
S
(6)
GC70…F
BAR CLAMP FOR HOCKEY PUK DEVICES
BAR CLAMP OUTLINES
95
39
Ø12
58
14
12
29
S
50 up to 120
58
S
T
12
T
Ø12
12
12
12
50 up to 120
14
95
25
70
25
70
GC70BN...F
GC70BR...F
95
70
T
12
S
50 up to 120
Ø12
58
14
22 Min.
S
Ø12
25
70
GC70SN...F
25
58
12
12
T
12
50 up to 120
14
95
GC70SR...F
Dimensions in mm - Tolerances according to ISO 2768 MK
#
GC70…F
BAR CLAMP FOR HOCKEY PUK DEVICES
S' Min
S Max
OPTIONAL BAR SPACER
S Min
PRESSURE DISC
SPECIAL ACCESSORIES
The following special accessories are available on request (see ordering information table)
95
4
Ø13
25
Bar spacer
Dimensions in mm - Tolerances according to ISO 2768 MK
In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet
without notice.
#